Skip to main content

Showing 1–8 of 8 results for author: Mohammed, M

Searching in archive nucl-ex. Search in all archives.
.
  1. Testing CPT symmetry in ortho-positronium decays with positronium annihilation tomography

    Authors: Paweł Moskal, Aleksander Gajos, Muhsin Mohammed, Jyoti Chhokar, Neha Chug, Catalina Curceanu, Eryk Czerwiński, Meysam Dadgar, Kamil Dulski, Marek Gorgol, Jacek Goworek, Beatrix Hiesmayr, Bożena Jasińska, Krzysztof Kacprzak, Łukasz Kapłon, Hanieh Karimi, Daria Kisielewska, Konrad Klimaszewski, Grzegorz Korcyl, Paweł Kowalski, Nikodem Krawczyk, Wojciech Krzemień, Tomasz Kozik, Ewelina Kubicz, Szymon Niedźwiecki , et al. (13 additional authors not shown)

    Abstract: Charged lepton system symmetry under combined charge, parity, and time-reversal transformation (CPT) remains scarcely tested. Despite stringent quantum-electrodynamic limits, discrepancies in predictions for the electron-positron bound state (positronium atom) motivate further investigation, including fundamental symmetry tests. While CPT noninvariance effects could be manifested in non-vanishing… ▽ More

    Submitted 8 December, 2021; originally announced December 2021.

    Comments: This is a preprint of an article published in Nature Communications. The final version is available at https://rdcu.be/cCQqq

    Journal ref: Nature Communications 12, 5658 (2021)

  2. arXiv:2006.07467  [pdf, other

    physics.ins-det nucl-ex

    The J-PET detector -- a tool for precision studies of ortho-positronium decays

    Authors: K. Dulski, S. D. Bass, J. Chhokar, N. Chug, C. Curceanu, E. Czerwiński, M. Dadgar, J. Gajewski, A. Gajos, M. Gorgol, R. Del Grande, B. C. Hiesmayr, B. Jasińska, K. Kacprzak, Ł. Kapłon, H. Karimi, D. Kisielewska, K. Klimaszewski, P. Kopka, G. Korcyl, P. Kowalski, T. Kozik, N. Krawczyk, W. Krzemień, E. Kubicz , et al. (19 additional authors not shown)

    Abstract: The J-PET tomograph is constructed from plastic scintillator strips arranged axially in concentric cylindrical layers. It enables investigations of positronium decays by measurement of the time, position, polarization and energy deposited by photons in the scintillators, in contrast to studies conducted so far with crystal and semiconductor based detection systems where the key selection of events… ▽ More

    Submitted 25 May, 2021; v1 submitted 9 June, 2020; originally announced June 2020.

    Comments: 12 pages, 7 figures

  3. arXiv:1809.05175  [pdf, other

    physics.ins-det nucl-ex

    Commissioning of the J-PET detector in view of the positron annihilation lifetime spectroscopy

    Authors: K. Dulski, C. Curceanu, E. Czerwiński, A. Gajos, M. Gorgol, N. Gupta-Sharma, B. C. Hiesmayr, B. Jasińska, K. Kacprzak Ł. Kapłon, D. Kisielewska, K. Klimaszewski, G. Korcyl, P. Kowalski, N. Krawczyk, W. Krzemień, T. Kozik, E. Kubicz, M. Mohammed, Sz. Niedźwiecki, M. Pałka, M. Pawlik-Niedźwiecka, L. Raczyński, J. Raj, K. Rakoczy, Z. Rudy , et al. (8 additional authors not shown)

    Abstract: The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET device built from plastic scintillators. It is a multi-purpose detector designed for medical imaging and for studies of properties of positronium atoms in porous matter and in living organisms. In this article we report on the commissioning of the J-PET detector in view of studies of positronium decays. We present results of ana… ▽ More

    Submitted 12 September, 2018; originally announced September 2018.

    Comments: 5 pages, 2 figures

  4. arXiv:1710.05611  [pdf, other

    physics.ins-det nucl-ex

    Analysis procedure of the positronium lifetime spectra for the J-PET detector

    Authors: K. Dulski, B. Zgardzinska, P. Bialas, C. Curceanu E. Czerwinski, A. Gajos, B. Głowacz, M. Gorgol, B. C. Hiesmayr, B. Jasinska, D. Kisielewska-Kaminska, G. Korcyl, P. Kowalski, T. Kozik, N. Krawczyk, W. Krzemiez, E. Kubicz, M. Mohammed, M. Pawlik-Niedzwiecka, S. Niedzwiecki, M. Palka, L. Raczynski, J. Raj, Z. Rudy, N. G. Sharma, S. Sharma , et al. (8 additional authors not shown)

    Abstract: Positron Annihilation Lifetime Spectroscopy (PALS) has shown to be a powerful tool to study the nanostructures of porous materials. Positron Emissions Tomography (PET) are devices allowing imaging of metabolic processes e.g. in human bodies. A newly developed device, the J-PET (Jagiellonian PET), will allow PALS in addition to imaging, thus combining both analyses providing new methods for physics… ▽ More

    Submitted 16 October, 2017; originally announced October 2017.

    Comments: 4 figures, 8 pages

  5. arXiv:1710.05598  [pdf, other

    physics.ins-det nucl-ex

    Time calibration of the J-PET detector

    Authors: M. Skurzok, M. Silarski, D. Alfs, P. Bialas, Shivani, C. Curceanu, E. Czerwinski, K. Dulski, A. Gajos, B. Glowacz, M. Gorgol, B. C. Hiesmayr, B. Jasinska, D. Kisielewska-Kaminska, G. Korcyl, P. Kowalski, T. Kozik, N. Krawczyk, W. Krzemien, E. Kubicz, M. Mohammed, M. Pawlik-Niedzwiecka, S. Niedzwiecki, M. Palka, L. Raczynski , et al. (10 additional authors not shown)

    Abstract: The Jagiellonian Positron Emission Tomograph (J-PET) project carried out in the Institute of Physics of the Jagiellonian University is focused on construction and tests of the first prototype of PET scanner for medical diagnostic which allows for the simultaneous 3D imaging of the whole human body using organic scintillators. The J-PET prototype consists of 192 scintillator strips forming three cy… ▽ More

    Submitted 16 October, 2017; originally announced October 2017.

    Comments: Accepted to publish in Acta Phys. Pol. A

  6. arXiv:1602.07528  [pdf, other

    physics.ins-det nucl-ex

    Trilateration-based reconstruction of ortho-positronium decays into three photons with the J-PET detector

    Authors: A. Gajos, D. Kamińska, E. Czerwiński, D. Alfs, T. Bednarski, P. Białas, B. Głowacz, M. Gorgol, B. Jasińska, Ł. Kapłon, G. Korcyl, P. Kowalski, T. Kozik, W. Krzemień, E. Kubicz, M. Mohammed, Sz. Niedźwiecki, M. Pałka, M. Pawlik-Niedźwiecka, L. Raczyński, Z. Rudy, O. Rundel, N. G. Sharma, M. Silarski, A. Słomski , et al. (6 additional authors not shown)

    Abstract: This work reports on a new reconstruction algorithm allowing to reconstruct the decays of ortho-positronium atoms into three photons using the places and times of photons recorded in the detector. The method is based on trilateration and allows for a simultaneous reconstruction of both location and time of the decay. Results of resolution tests of the new reconstruction in the J-PET detector based… ▽ More

    Submitted 24 February, 2016; originally announced February 2016.

    Comments: 18 pages, 5 figures. Accepted for publication in Nuclear Instrumentation and Methods in Physics Research A

  7. arXiv:1602.05376  [pdf

    nucl-ex physics.ins-det

    Determination of the 3γfraction from positron annihilation in mesoporous materials for symmetry violation experiment with J-PET scanner

    Authors: B. Jasińska, M. Gorgol, M. Wiertel, R. Zaleski, D. Alfs, T. Bednarski, P. Białas, E. Czerwiński, K. Dulski, A. Gajos, B. Głowacz, D. Kamińska, Ł. Kapłon, G. Korcyl, P. Kowalski, T. Kozik, W. Krzemień, E. Kubicz, M. Mohammed, Sz. Niedźwiecki, M. Pałka, L. Raczyński, Z. Rudy, O. Rundel, N. G. Sharma , et al. (8 additional authors not shown)

    Abstract: Various mesoporous materials were investigated to choose the best material for experiments requiring high yield of long-lived positronium. We found that the fraction of 3γannihilation determined using γ-ray energy spectra and positron annihilation lifetime spectra (PAL) changed from 20% to 25%. The 3gamma fraction and o-Ps formation probability in the polymer XAD-4 is found to be the largest. Elem… ▽ More

    Submitted 17 February, 2016; originally announced February 2016.

    Comments: 12 pages, 2 figures

  8. arXiv:1602.05226  [pdf, other

    nucl-ex physics.ins-det

    Potential of the J-PET detector for studies of discrete symmetries in decays of positronium atom - a purely leptonic system

    Authors: P. Moskal, D. Alfs, T. Bednarski, P. Białas, E. Czerwiński, C. Curceanu, A. Gajos, B. Głowacz, M. Gorgol, B. C. Hiesmayr, B. Jasińska, D. Kamińska, G. Korcyl, P. Kowalski, T. Kozik, W. Krzemień, N. Krawczyk, E. Kubicz, M. Mohammed, Sz. Niedźwieckia, M. Pawlik-Niedźwiecka, L. Raczyński, Z. Rudy, M. Silarski, A. Wieczorek , et al. (2 additional authors not shown)

    Abstract: The Jagiellonian Positron Emission Tomograph (J-PET) was constructed as a prototype of the cost-effective scanner for the simultaneous metabolic imaging of the whole human body. Being optimized for the detection of photons from the electron-positron annihilation with high time- and high angular-resolution, it constitutes a multi-purpose detector providing new opportunities for studying the decays… ▽ More

    Submitted 16 February, 2016; originally announced February 2016.

    Comments: 27 pages, 6 figures

    Journal ref: Acta Phys.Polon. B47 (2016) 509