-
Intelligent Blockage Prediction and Proactive Handover for Seamless Connectivity in Vision-Aided 5G/6G UDNs
Authors:
Mohammad Al-Quraan,
Ahsan Khan,
Lina Mohjazi,
Anthony Centeno,
Ahmed Zoha,
Muhammad Ali Imran
Abstract:
The upsurge in wireless devices and real-time service demands force the move to a higher frequency spectrum. Millimetre-wave (mmWave) and terahertz (THz) bands combined with the beamforming technology offer significant performance enhancements for ultra-dense networks (UDNs). Unfortunately, shrinking cell coverage and severe penetration loss experienced at higher spectrum render mobility managemen…
▽ More
The upsurge in wireless devices and real-time service demands force the move to a higher frequency spectrum. Millimetre-wave (mmWave) and terahertz (THz) bands combined with the beamforming technology offer significant performance enhancements for ultra-dense networks (UDNs). Unfortunately, shrinking cell coverage and severe penetration loss experienced at higher spectrum render mobility management a critical issue in UDNs, especially optimizing beam blockages and frequent handover (HO). Mobility management challenges have become prevalent in city centres and urban areas. To address this, we propose a novel mechanism driven by exploiting wireless signals and on-road surveillance systems to intelligently predict possible blockages in advance and perform timely HO. This paper employs computer vision (CV) to determine obstacles and users' location and speed. In addition, this study introduces a new HO event, called block event {BLK}, defined by the presence of a blocking object and a user moving towards the blocked area. Moreover, the multivariate regression technique predicts the remaining time until the user reaches the blocked area, hence determining best HO decision. Compared to typical wireless networks without blockage prediction, simulation results show that our BLK detection and PHO algorithm achieves 40\% improvement in maintaining user connectivity and the required quality of experience (QoE).
△ Less
Submitted 21 February, 2022;
originally announced March 2022.
-
A Model-Agnostic Method for PMU Data Recovery Using Optimal Singular Value Thresholding
Authors:
Shuchismita Biswas,
Virgilio A. Centeno
Abstract:
This paper presents a fast model-agnostic method for recovering noisy Phasor Measurement Unit (PMU) datastreams with missing entries. The measurements are first transformed into a Page matrix, and the original signals are reconstructed using low-rank matrix estimation based on optimal singular value thresholding. Two variations of the recovery algorithm are shown- a) an offline block-processing me…
▽ More
This paper presents a fast model-agnostic method for recovering noisy Phasor Measurement Unit (PMU) datastreams with missing entries. The measurements are first transformed into a Page matrix, and the original signals are reconstructed using low-rank matrix estimation based on optimal singular value thresholding. Two variations of the recovery algorithm are shown- a) an offline block-processing method for imputing past measurements, and b) an online method for predicting future measurements. Information within a PMU channel (temporal correlation) as well as from different PMUchannels in a network (spatial correlation) are utilized to recover degraded data. The proposed method is fast and needs no explicit knowledge of the underlying system model or measurement noise distribution. The performance of the recovery algorithms is illustrated using simulated measurements from the IEEE 39-bus test system as well as real measurements from an anonymized U.S. electric utility. Extensive numeric tests show that the original signals can be accurately recovered in the presence of additive noise, consecutive data drop as well as simultaneous data erasure across multiple PMU channels.
△ Less
Submitted 6 August, 2021;
originally announced August 2021.
-
All-Digital FPGA-based DAC with None or Few External Components
Authors:
Luis E. Rueda G.,
Edward Silva,
Andres Centeno,
Elkim Roa
Abstract:
One of the many limitations with the mixed-signal design is physically testing circuit ideas. While it is easier to test digital circuits with FPGAs, this can not be done usually with mixed-signal circuits. Although some FPGAs have built-in analog-to-digital and digital-to-analog converters, regular commercial FPGAs development boards and low-cost FPGAs lack built-in data converters. Here we intro…
▽ More
One of the many limitations with the mixed-signal design is physically testing circuit ideas. While it is easier to test digital circuits with FPGAs, this can not be done usually with mixed-signal circuits. Although some FPGAs have built-in analog-to-digital and digital-to-analog converters, regular commercial FPGAs development boards and low-cost FPGAs lack built-in data converters. Here we introduce an all-digital FPGA-based DAC, which is one of the main blocks to enable mixed-signal experiments. The DAC can be synthesized entirely in an FPGA and does not require the use of external components. Furthermore, and to extend its range of applications, a discussion regarding the proposed DAC's problems and possible solutions is presented. Experimental demonstration of a 4-bit and a 5-bit DAC corroborate the theoretical analysis developed in this work. This work also suggests a scheme which includes few external resistors to improve the linearity (DNL$\leq$0.25LSB and an INL$\leq$0.5LSB), and the power consumption (5X improvement over the standalone configuration).
△ Less
Submitted 2 August, 2020;
originally announced August 2020.
-
Towards Critical Clearing Time Sensitivity for DAE Systems with Singularity
Authors:
Chetan Mishra,
Chen Wang,
Xin Xu,
Virgilio A. Centeno
Abstract:
Standard power system models are parameter dependent differential-algebraic equation (DAE) type. Following a transient event, voltage collapse can occur as a bifurcation of the transient load flow solutions which is marked by the system trajectory reaching a singular surface in state space where the voltage causality is lost. If a fault is expected to cause voltage collapse, preventive control dec…
▽ More
Standard power system models are parameter dependent differential-algebraic equation (DAE) type. Following a transient event, voltage collapse can occur as a bifurcation of the transient load flow solutions which is marked by the system trajectory reaching a singular surface in state space where the voltage causality is lost. If a fault is expected to cause voltage collapse, preventive control decisions such as changes in AVR settings need to be taken in order to get enhance the system stability. In this regard, the knowledge of sensitivity of critical clearing time (CCT) to controllable system parameters can be of great help. The quasi-stability boundary of DAE systems is more complicated than ODE systems where in addition to unstable equilibrium points (UEP) and periodic orbits, singularity plays an important role making the problem challenging. The stability boundary is then made up of a number of dynamically distinct components. In the present work, we derive the expression for CCT sensitivity for the phenomenon where the critical fault-on trajectory intersects the singular surface itself which is one such component forming the stability boundary. The results are illustrated for a small test system in order to gain visual insights.
△ Less
Submitted 20 February, 2020;
originally announced February 2020.
-
Low Voltage Ride Through (LVRT) Constrained Transient Stability Assessment Using Lyapunov Functions Family Method
Authors:
Chen Wang,
Chetan Mishra,
Virgilio A. Centeno
Abstract:
Growing penetration of renewable generation in power systems brings more challenges in transient stability assessment using direct methods. One of the reasons is the inability to assess the risk of instability brought by tripping of a large amount of RGs due to violation of their ride through curves. In this paper, a scalable approach is proposed based on the Lyapunov functions family to estimate…
▽ More
Growing penetration of renewable generation in power systems brings more challenges in transient stability assessment using direct methods. One of the reasons is the inability to assess the risk of instability brought by tripping of a large amount of RGs due to violation of their ride through curves. In this paper, a scalable approach is proposed based on the Lyapunov functions family to estimate the stability region under ride through constraints. An inner polytopic approximation to the feasibility region is proposed to convexify the overall problem. The acquired constrained stability region estimate helps capture trajectories that trigger undesirable tripping of renewable generation. A 2-machine system is used to visualize its effectiveness.
△ Less
Submitted 3 February, 2020;
originally announced February 2020.
-
Adaptive LVRT Settings Adjustment for Enhancing Voltage Security of Renewable-Rich Electric Grids
Authors:
Chen Wang,
Chetan Mishra,
Reetam Sen Biswas,
Anamitra Pal,
Virgilio A. Centeno
Abstract:
Inverter based renewable generation (RG), especially at the distribution level, is supposed to trip offline during an islanding situation. However, islanding detection is done by comparing the voltage and frequency measurements at the point of common coupling (PCC), with limits defined in the form of ride-through curves. Current practice is to use the same limit throughout the year independent of…
▽ More
Inverter based renewable generation (RG), especially at the distribution level, is supposed to trip offline during an islanding situation. However, islanding detection is done by comparing the voltage and frequency measurements at the point of common coupling (PCC), with limits defined in the form of ride-through curves. Current practice is to use the same limit throughout the year independent of the operating conditions. This could result in the tripping of RG at times when the system is already weak, thereby posing a threat to voltage security by heavily limiting the load margin (LM). Conversely, heavily relaxing these limits would result in scenarios where the generation does not go offline even during an islanding situation. The proposed methodology focuses on optimizing low-voltage ride-through (LVRT) settings at selective RGs as a preventive control for maintaining a desired steady-state voltage stability margin while not sacrificing dependability during islanding. The proposed process is a multi-stage approach, in which at each stage, a subset of estimated poor-quality solutions is screened out based on various sensitivities. A full continuation power flow (CPFLOW) is only run at the beginning and in the last stage on a handful of remaining candidate solutions, thereby cutting down heavily on the computation time. The effectiveness of the approach is demonstrated on the IEEE 9-bus system.
△ Less
Submitted 25 January, 2020;
originally announced January 2020.
-
Transmission Lines Positive Sequence Parameters Estimation and Instrument Transformers Calibration Based on PMU Measurement Error Model
Authors:
Chen Wang,
Virgilio A. Centeno,
Kevin D. Jones,
Duotong Yang
Abstract:
Phasor Measurement Unit measurement data have been widely used in nowadays power system applications both in steady state and dynamic analysis. The performance of these applications running in utilities' energy management system depends heavily on an accurate positive sequence power system model. However, it is impractical to find this accurate model with transmission line parameters calculated di…
▽ More
Phasor Measurement Unit measurement data have been widely used in nowadays power system applications both in steady state and dynamic analysis. The performance of these applications running in utilities' energy management system depends heavily on an accurate positive sequence power system model. However, it is impractical to find this accurate model with transmission line parameters calculated directly with the PMU measurements due to ratio errors brought by instrument transformers and communication errors brought by PMUs. Therefore, a methodology is proposed in this paper to estimate the actual transmission lines parameters throughout the whole system and, at the same time, calibrate the corresponding instrument transformers. A PMU positive sequence measurement error model is proposed targeting at the aforementioned errors, which is applicable to both transposed and un-transposed transmission lines. A single line parameters estimation method is designed based on Least Squares Estimation and this error model. This method requires only one set of reference measurements and the accuracy can be propagated throughout the whole network along with the topology acquired by the introduced Edge-based Breadth-first Search algorithm. The IEEE 118-bus system and the Texas 2000-bus system are used to demonstrate the effectiveness and efficiency of the proposed method. The potential for deployment in reality is also discussed.
△ Less
Submitted 4 November, 2019;
originally announced November 2019.
-
Critical Clearing Time Sensitivity for Inequality Constrained Systems
Authors:
Chetan Mishra,
Anamitra Pal,
Virgilio A. Centeno
Abstract:
From a stability perspective, a renewable generation (RG)-rich power system is a constrained system. As the quasistability boundary of a constrained system is structurally very different from that of an unconstrained system, finding the sensitivity of critical clearing time (CCT) to change in system parameters is very beneficial for a constrained power system, especially for planning/revising cons…
▽ More
From a stability perspective, a renewable generation (RG)-rich power system is a constrained system. As the quasistability boundary of a constrained system is structurally very different from that of an unconstrained system, finding the sensitivity of critical clearing time (CCT) to change in system parameters is very beneficial for a constrained power system, especially for planning/revising constraints arising from system protection settings. In this paper, we derive the first order sensitivity of a constrained power system using trajectory sensitivities of fault-on and post-fault trajectories. The results for the test system demonstrate the dependence between ability to meet angle and frequency constraints, and change in power system parameters such as operating conditions and inertia.
△ Less
Submitted 23 February, 2019;
originally announced February 2019.
-
Transient Stability Assessment of Cascade Tripping of Renewable Sources Using SOS
Authors:
Chetan Mishra,
James S. Thorp,
Anamitra Pal,
Virgilio A. Centeno
Abstract:
There has been significant increase in penetration of renewable generation (RG) sources all over the world. Localized concentration of many such generators could initiate a cascade tripping sequence that might threaten the stability of the entire system. Understanding the impact of cascade tripping process would help the system planner identify trip sequences that must be blocked in order to incre…
▽ More
There has been significant increase in penetration of renewable generation (RG) sources all over the world. Localized concentration of many such generators could initiate a cascade tripping sequence that might threaten the stability of the entire system. Understanding the impact of cascade tripping process would help the system planner identify trip sequences that must be blocked in order to increase stability. In this work, we attempt to understand the consequences of cascade tripping mechanism through a Lyapunov approach. A conservative definition for the stability region (SR) along with its estimation for a given cascading sequence using sum of squares (SOS) programming is proposed. Finally, a simple probabilistic definition of the SR is used to visualize the risk of instability and understand the impact of blocking trip sequences. A 3-machine system with significant RG penetration is used to demonstrate the idea.
△ Less
Submitted 12 February, 2018;
originally announced February 2018.