A wireless accelerometer node for reliable and valid measurement of lumbar accelerations during treadmill running

Sports Biomech. 2016;15(1):11-22. doi: 10.1080/14763141.2015.1123760. Epub 2016 Feb 2.

Abstract

This study investigated the reliability of a wireless accelerometer and its agreement with optical motion capture for the measurement of root mean square (RMS) acceleration during running. RMS acceleration provides a whole-body metric of movement mechanics and economy. Fifteen healthy college-age participants performed treadmill running for two 60-s trials at 2.22, 2.78, and 3.33 m/s and one trial of 150 s (five 30-s epochs) at 2.78 m/s. We assessed between-trial and within-trial reliability, and agreement in each axis between a trunk-mounted wireless accelerometer and a reflective marker on the accelerometer measured by optical motion capture. Intraclass correlations assessing between-trial repeatability were 0.89-0.97, depending on the axis, and intraclass correlations assessing within-trial repeatability were 0.99-1.00. Bland-Altman analyses assessing agreement indicated mean difference values between -0.03 and 0.03 g, depending on the axis. Anterio-posterior acceleration had the greatest limits of agreement (LOA) (±0.12 g) and vertical acceleration had the smallest LOA (±0.03 g). For measuring RMS acceleration of the trunk, this wireless accelerometer node provides repeatable and valid measurement compared with the standard laboratory method of optical motion capture.

Keywords: Optical motion capture; agreement; root mean square.

MeSH terms

  • Accelerometry / instrumentation*
  • Adult
  • Equipment Design
  • Exercise Test
  • Female
  • Gait / physiology
  • Humans
  • Lumbosacral Region / physiology*
  • Male
  • Movement / physiology
  • Reproducibility of Results
  • Running / physiology*
  • Young Adult