Abstract
Background and objectives
We compared ureteral anastomosis using a laser and intraluminal albumin stent with both conventional suturing and laser soldering techniques.Study design/materials and methods
Twelve pigs underwent bilateral ureteral anastomoses (N = 24) using one of the three anastomotic methods: (1) laser welding with intraluminal albumin stent (N = 11); (2) with albumin solder (N = 8); and (3) conventional suturing (N = 5). Operative parameters, leakage rate, intrapelvic perfusion pressure, urography, and histology of the anastomoses were examined.Results
Operative time for ureteral anastomosis in the stent and solder groups were significantly shorter than the suture group (means 370 seconds and 360 vs. 710 seconds, both P = 0.02). Leakage rate of the anastomoses was lower in the stent group (9%, 1/11) as compared to the solder group (25%, 2/8). The Whitaker test showed that the intrapelvic perfusion pressure elevated gradually after anastomosis and significantly increased at 4 weeks postoperatively in all three methods. Various degrees of hydronephrosis were also noticed in three groups after 4 weeks of surgery.Conclusions
Use of the intraluminal albumin stent increased the reliability of laser welding for ureteral anastomosis. The clinical significance of using this technique should be investigated further.Full text links
Read article at publisher's site: https://doi.org/10.1002/lsm.10164
Citations & impact
Impact metrics
Citations of article over time
Article citations
Therapeutic applications of lasers in urology: an update.
Expert Rev Med Devices, 3(1):81-94, 01 Jan 2006
Cited by: 21 articles | PMID: 16359255
Review
Intraluminal laser light source and external solder: in vivo evaluation of a new technique for microvascular anastomosis.
Lasers Surg Med, 35(4):312-316, 01 Jan 2004
Cited by: 18 articles | PMID: 15493022
Laser-assisted end-to-end vascular anastomosis of elastin heterograft to carotid artery with an albumin stent in vivo.
Photomed Laser Surg, 22(4):298-302, 01 Aug 2004
Cited by: 4 articles | PMID: 15345171
Laser-assisted vascular end to end anastomosis of elastin heterograft to carotid artery with an albumin stent: a preliminary in vivo study.
Lasers Surg Med, 35(3):201-205, 01 Jan 2004
Cited by: 12 articles | PMID: 15389735
Laser literature watch.
J Clin Laser Med Surg, 21(6):391-400, 01 Dec 2003
Cited by: 1 article | PMID: 14709226
Similar Articles
To arrive at the top five similar articles we use a word-weighted algorithm to compare words from the Title and Abstract of each citation.
Intraluminal albumin stent assisted laser welding for ureteral anastomosis.
Lasers Surg Med, 31(4):225-229, 01 Jan 2002
Cited by: 3 articles | PMID: 12355565
In vitro large diameter bowel anastomosis using a temperature controlled laser tissue soldering system and albumin stent.
Lasers Surg Med, 41(7):504-508, 01 Sep 2009
Cited by: 11 articles | PMID: 19670327
Intraluminal laser light source and external solder: in vivo evaluation of a new technique for microvascular anastomosis.
Lasers Surg Med, 35(4):312-316, 01 Jan 2004
Cited by: 18 articles | PMID: 15493022
Laser welding--suitable for vascular anastomosis?
Thorac Cardiovasc Surg, 42(6):333-336, 01 Dec 1994
Cited by: 4 articles | PMID: 7534952
Review