Abstract 


Aim

To investigate the impact of different spectral Doppler criteria on the proportion of high-grade ICA stenosis in patients undergoing carotid artery duplex scanning.

Material and methods

Duplex scans of 4,548 internal carotid arteries (ICA) in 2,349 patients were retrospectively analyzed. The following different criteria were applied for each scan for definition of ICA stenosis > or = 70%: Criteria I=ICA peak systolic velocity (PSV) > 130 cm/sec and ICA end-diastolic (EDV) > 100 cm/sec, Criteria II=PSV ICA/common carotid artery (CCA) ratio > 4, Criteria III=ICA PSV > or = 230 cm/sec, Criteria IV=ICA PSV > 230 cm/sec and/or ICA EDV > or = 100 cm/sec and/or PSV ICA/CCA ratio > or = 3.2.

Results

The frequency of detecting a > or = 70% ICA stenosis with criteria I, II, III, and IV were 5.5%, 6.8%, 8.4%, and 9.6%, respectively (p < 0.05).

Conclusion

The use of various duplex criteria significantly affected the number of scans receiving a diagnosis of ICA stenosis of > or = 70%.

References 


Articles referenced by this article (27)


Show 10 more references (10 of 27)

Citations & impact 


Impact metrics

Jump to Citations

Citations of article over time

Smart citations by scite.ai
Smart citations by scite.ai include citation statements extracted from the full text of the citing article. The number of the statements may be higher than the number of citations provided by EuropePMC if one paper cites another multiple times or lower if scite has not yet processed some of the citing articles.
Explore citation contexts and check if this article has been supported or disputed.
https://scite.ai/reports/10.1177/000331970205300307

Supporting
Mentioning
Contrasting
0
5
0

Article citations