CERN Accélérateur de science

CERN Document Server 6 notices trouvées  La recherche a duré 0.84 secondes. 
1.
Generating a highly uniform magnetic field inside the magnetically shielded room of the n2EDM experiment / Abel, C. (Sussex U.) ; Ayres, N.J. (Zurich, ETH) ; Ban, G. (LPC, Caen) ; Bison, G. (PSI, Villigen) ; Bodek, K. (Jagiellonian U.) ; Bondar, V. (Zurich, ETH) ; Bouillaud, T. (LPSC, Grenoble) ; Bowles, D.C. (Kentucky U.) ; Caratsch, G.L. (PSI, Villigen ; Zurich, ETH) ; Chanel, E. (Bern U.) et al.
We present a coil system designed to generate a highly uniform magnetic field for the n2EDM experiment at the Paul Scherrer Institute. It consists of a main $B_0$ coil and a set of auxiliary coils mounted on a cubic structure with a side length of 273 cm, inside a large magnetically shielded room (MSR). [...]
arXiv:2410.07914.- 2025-02-20 - 19 p. - Published in : Eur. Phys. J. C 85 (2025) 202 Fulltext: Publication - PDF; 2410.07914 - PDF;
2.
Demonstration of the light collection stability of a PEN-based wavelength shifting reflector in a tonne scale liquid argon detector / Gupta, V. (Amsterdam U. ; NIKHEF, Amsterdam) ; Araujo, G.R. (Zurich U.) ; Babicz, M. (Zurich U.) ; Baudis, L. (Zurich U.) ; Chiu, P.-J. (Zurich U.) ; Choudhary, S. (Warsaw, Copernicus Astron. Ctr.) ; Goldbrunner, M. (Munich, Tech. U.) ; Hamer, A. (Edinburgh U.) ; Kuźniak, M. (Warsaw, Copernicus Astron. Ctr.) ; Kuźwa, M. (Warsaw, Copernicus Astron. Ctr.) et al.
Liquid argon detectors rely on wavelength shifters for efficient detection of scintillation light. The current standard is tetraphenyl butadiene (TPB), but it is challenging to instrument on a large scale. [...]
arXiv:2411.17934.- 2025-05-27 - 10 p. - Published in : JINST 20 (2025) C05033 Fulltext: 2411.17934 - PDF; document - PDF;
In : Light Detection in Noble Elements 2024, São Paulo, Brazil, 26 - 28 Aug 2024, pp.C05033
3.
Measurement of the Permanent Electric Dipole Moment of the Neutron / Abel, C. (Sussex U.) ; Afach, S. (PSI, Villigen ; Zurich, ETH) ; Ayres, N.J. (Sussex U. ; Zurich, ETH) ; Baker, C.A. (Rutherford) ; Ban, G. (Caen U.) ; Bison, G. (PSI, Villigen) ; Bodek, K. (Jagiellonian U.) ; Bondar, V. (PSI, Villigen ; Zurich, ETH ; Leuven U.) ; Burghoff, M. (Berlin, Phys. Tech. Bund.) ; Chanel, E. (U. Bern, AEC) et al.
We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey's method of separated oscillating magnetic fields with ultracold neutrons (UCN). Our measurement stands in the long history of EDM experiments probing physics violating time reversal invariance. [...]
arXiv:2001.11966.- 2020-02-29 - 7 p. - Published in : Phys. Rev. Lett. 124 (2020) 081803 Article from SCOAP3: PDF; Fulltext: PDF;
4.
Optically pumped Cs magnetometers enabling a high-sensitivity search for the neutron electric dipole moment / Abel, C. (Sussex U.) ; Afach, S. (PSI, Villigen ; Zurich, ETH) ; Ayres, N.J. (Sussex U. ; Zurich, ETH) ; Ban, G. (Caen U.) ; Bison, G. (PSI, Villigen) ; Bodek, K. (Jagiellonian U.) ; Bondar, V. (PSI, Villigen ; Zurich, ETH ; Leuven U.) ; Chanel, E. (U. Bern, AEC) ; Chiu, P.-J (PSI, Villigen ; Zurich, ETH) ; Crawford, C.B. (Kentucky U.) et al.
An array of sixteen laser-pumped scalar Cs magnetometers was part of the neutron electric dipole moment (nEDM) experiment taking data at the Paul Scherrer Institute in 2015 and 2016. It was deployed to measure the gradients of the experiment's magnetic field and to monitor their temporal evolution. [...]
arXiv:1912.04631.- 2020-05-12 - 17 p. - Published in : Phys. Rev. A 101 (2020) 053419 Fulltext: PDF;
5.
Data blinding for the nEDM experiment at PSI / Ayres, N.J. (Zurich, ETH ; Sussex U.) ; Ban, G. (Caen U.) ; Bison, G. (PSI, Villigen) ; Bodek, K. (Jagiellonian U.) ; Bondar, V. (Zurich, ETH ; PSI, Villigen ; Leuven U.) ; Chanel, E. (U. Bern, AEC) ; Chiu, P.J. (PSI, Villigen ; Zurich, ETH) ; Crawford, C.B. (Kentucky U.) ; Daum, M. (PSI, Villigen) ; Emmenegger, S. (Zurich, ETH) et al.
Psychological bias towards, or away from, a prior measurement or a theory prediction is an intrinsic threat to any data analysis. While various methods can be used to avoid the bias, e.g. [...]
arXiv:1912.09244.- 2021-04-28 - 13 p. - Published in : Eur. Phys. J. A Fulltext: PDF; Fulltext from Publisher: PDF;
6.
ProtoDUNE-DP---PROTOtype for the Deep Underground Neutrino Experiment - Dual Phase detector (Electrostatic Simulations and Performance Studies) / Chiu, Pin-Jung
In search of answers to the biggest missing puzzle in the field of neutrino physics, large- scale Liquid Argon Time Projection Chambers (LAr-TPCs) have been postulated to be the most attractive instruments for next generation neutrino observations [...]
CERN-THESIS-2017-150 - 80.


10.3929/ethz-b-000185858

Voir aussi: noms d'auteurs similaires
1 Chiu, P
3 Chiu, P C
1 Chiu, P J
1 Chiu, P T
1 Chiu, P W
3 Chiu, P.
1 Chiu, P.-J
3 Chiu, P.-J.
1 Chiu, Peggy
1 Chiu, Pin-Jung
1 Chiu, Pin-Yi
Vous désirez être averti des nouveaux résultats pour cette recherche?
Abonnez-vous à une alerte email personnalisée ou inscrivez-vous via le flux RSS.
Vous n'avez pas trouvé ce que vous avez cherché? Essayez votre requête sur d'autres serveurs:
Chiu, P.J. dans Amazon
Chiu, P.J. dans CERN EDMS
Chiu, P.J. dans CERN Intranet
Chiu, P.J. dans CiteSeer
Chiu, P.J. dans Google Books
Chiu, P.J. dans Google Scholar
Chiu, P.J. dans Google Web
Chiu, P.J. dans IEC
Chiu, P.J. dans IHS
Chiu, P.J. dans INSPIRE
Chiu, P.J. dans ISO
Chiu, P.J. dans KISS Books/Journals
Chiu, P.J. dans KISS Preprints
Chiu, P.J. dans NEBIS
Chiu, P.J. dans SLAC Library Catalog
Chiu, P.J. dans Scirus