CERN Accelerating science

CERN Document Server 20 records found  1 - 10next  jump to record: Search took 0.77 seconds. 
1.
The very forward CASTOR calorimeter of the CMS experiment / CMS Collaboration
The physics motivation, detector design, triggers, calibration, alignment, simulation, and overall performance of the very forward CASTOR calorimeter of the CMS experiment are reviewed. The CASTOR Cherenkov sampling calorimeter is located very close to the LHC beam line, at a radial distance of about 1 cm from the beam pipe, and at 14.4 m from the CMS interaction point, covering the pseudorapidity range of $-6.6 < \eta < -5.2$. [...]
arXiv:2011.01185; CMS-PRF-18-002; CERN-EP-2020-180; CMS-PRF-18-002; CERN-EP-2020-180; CMS-PRF-18-002-003.- Geneva : CERN, 2021-02-08 - 65 p. - Published in : JINST 16 (2021) P02010 Fulltext: 2011.01185 - PDF; fermilab-pub-20-696-cms-scd - PDF; Fulltext from Publisher: PDF; External link: Fermilab Library Server
2.
Development of the optical system for the SST-1M telescope of the Cherenkov Telescope Array observatory / Seweryn, K. ; Bilnik, W. (AGH-UST, Cracow) ; Błocki, J. (Cracow, INP) ; Bogacz, L. (Jagiellonian U.) ; Bulik, T. (Warsaw U. Observ.) ; Cadoux, F. (Geneva U.) ; Christov, A. (Geneva U.) ; Chruślińska, M. ; Curyło, M. (Cracow, INP) ; della Volpe, D. (INFN, Naples ; Naples U.) et al. /for the CTA Consortium
The prototype of a Davies-Cotton small size telescope (SST-1M) has been designed and developed by a consortium of Polish and Swiss institutions and proposed for the Cherenkov Telescope Array (CTA) observatory. The main purpose of the optical system is to focus the Cherenkov light emitted by extensive air showers in the atmosphere onto the focal plane detectors. [...]
arXiv:1508.06795.- SISSA, 2015-07-13 - 7 p. - Published in : PoS ICRC2015 (2016) 998 Fulltext: 1508.06795 - PDF; PoS(ICRC2015)998 - PDF; Preprint: PDF; Published version from PoS: PDF; External link: PoS server
In : 34th International Cosmic Ray Conference, The Hague, The Netherlands, 30 Jul - 6 Aug 2015, pp.998
3.
Camera calibration strategy of the SST-1M prototype of the Cherenokov Telescope Array / Prandini, E (INFN, Padua ; Padua U.) ; Heller, M. (CERN) ; Lyard, E. (Geneva U.) ; Schioppa, E. jr. ; Neronov, A. (ISDC, Versoix) ; Bilnik, W. ; Błocki, J. (Cracow, INP) ; Bogacz, L. (Bielefeld U. ; Jagiellonian U.) ; Bulik, T. (Warsaw U.) ; Cadoux, F. (Geneva U.) et al.
The SST-1M telescope is one of the prototypes under construction proposed to be part of the future Cherenkov Telescope Array. [...]
arXiv:1508.06397.
- 2015.
Preprint
4.
The CMS experiment at the CERN LHC / CMS Collaboration
2008 - 361 p. - Published in : JINST 3 (2008) S08004 SISSA/IOP Open Access article: PDF;
In : The CERN Large Hadron Collider - Please contact the library if you need to access this document.
5.
CMS Physics : Technical Design Report Volume 2: Physics Performance / Bayatian, G L
CERN-LHCC-2006-021 CMS-TDR-8-2. - Geneva : CERN, 2007. - 669 p. (Technical design report. CMS ; 8.2)


10.1088/0954-3899/34/6/S01
6.
CMS Physics : Technical Design Report Volume 1: Detector Performance and Software / Bayatian, G L
CERN-LHCC-2006-001 CMS-TDR-8-1. - Geneva : CERN, 2006. - 521 p. (Technical design report. CMS ; 8.1)

7.
First results from the PHOBOS experiment at RHIC / Wuosmaa, A H ; Back, B B ; Baker, M D ; Barton, D S ; Basilev, S N ; Bates, B D ; Baum, R ; Betts, R R ; Bialas, A ; Bindel, R et al.
2000
In : 16th International Conference on the Application of Accelerators in Research and Industry, Denton, TX, USA, 1 - 5 Nov 2000, pp.231-234
8.
The LHCb Inner Tracker cooling balcony and plate: Design and Material selection studies / Bösiger, K (Zurich U.) ; Lehner, F (Zurich U.) ; Michalowski, J (Cracow, INP ) ; Siegler, M (Zurich U.) ; Steiner, S (Zurich U.) ; Stodulski, M (Cracow, INP ) ; Zychowski, P (Cracow, INP )
This internal note presents the design and the specifications for the cooling balconies and cooling plate of the LHCb Inner Tracker silicon detector. We describe the material R&D; programme, which has been carried out in order to identify appropriate material candidates. [...]
LHCb-2002-061.- Geneva : CERN, 2002 - 18 p. Inner Tracker Access to fulltext document: PS.GZ; Fulltext: PDF;
9.
The mechanical design and support for the CASTOR calorimeter for ALICE / Bartke, Jerzy ; Blocki, J ; Mavromanolakis, G ; Panagiotou, A D ; Zychowski, P /ALICE Collaboration
The calorimeter is a structure built out of two sections (left and right), each of them consisting of four modules connected together at each corner through bolted plates, as can be seen in the general view (see Fig.1) and in the front view of the calorimeter (see Fig.2)..
ALICE-INT-1998-46; CERN-ALICE-INT-1998-46.- Geneva : CERN, 1998 Fulltext: PS.GZ;
10.
LHCb trigger system : Technical Design Report / LHCb Collaboration
CERN-LHCC-2003-031 ; LHCb-TDR-10.
- Geneva : CERN, 2003. - 92 p. (Technical design report. LHCb ; 10)
LHCb TDR home page - Access to fulltext document

CERN Document Server : 20 records found   1 - 10next  jump to record:
See also: similar author names
5 Zychowski, P.
24 Żychowski, P
5 Żychowski, P.
1 Żychowski, Paweł
Interested in being notified about new results for this query?
Set up a personal email alert or subscribe to the RSS feed.
Haven't found what you were looking for? Try your search on other servers:
Zychowski, P in Amazon
Zychowski, P in CERN EDMS
Zychowski, P in CERN Intranet
Zychowski, P in CiteSeer
Zychowski, P in Google Books
Zychowski, P in Google Scholar
Zychowski, P in Google Web
Zychowski, P in IEC
Zychowski, P in IHS
Zychowski, P in INSPIRE
Zychowski, P in ISO
Zychowski, P in KISS Books/Journals
Zychowski, P in KISS Preprints
Zychowski, P in NEBIS
Zychowski, P in SLAC Library Catalog
Zychowski, P in Scirus