CERN Accelerating science

CERN Document Server 268 Datensätze gefunden  1 - 10nächsteEnde  gehen zum Datensatz: Die Suche hat 1.52 Sekunden gedauert. 
1.
PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging / Kallitsopoulou, A. (IRFU, Saclay) ; Aleksan, R. (IRFU, Saclay) ; Angelis, Y. (Aristotle U., Thessaloniki) ; Aune, S. (IRFU, Saclay) ; Bortfeldt, J. (Munich U.) ; Brunbauer, F. (CERN) ; Brunoldi, M. (Pavia U. ; INFN, Pavia) ; Chatzianagnostou, E. (Aristotle U., Thessaloniki) ; Datta, J. (SUNY, Stony Brook) ; Desforge, D. (IRFU, Saclay) et al.
The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged particles in ionization gaps by using extreme UV Cherenkov light emitted in a crystal, detected by a Micromegas photodetector with an appropriate photocathode. [...]
arXiv:2411.02532.- 2024-10-16 - 4 p. Fulltext: PDF;
2.
Neutron imaging with Micromegas detectors with optical readout / Cools, A (IRFU, Saclay) ; Aune, S (IRFU, Saclay) ; Brunbauer, F M (CERN) ; Benoit, T (IRFU, Saclay) ; Corsi, A (IRFU, Saclay) ; Ferrer-Ribas, E (IRFU, Saclay) ; Iguaz, F J (SOLEIL, Saint-Aubin) ; Mazoin, C (IRFU, Saclay) ; Oliveri, E (CERN) ; Papaevangelou, T (IRFU, Saclay) et al.
Optical readout of Micromegas gaseous detectors has been achieved by implementing a Micromegas detector on a glass substrate with a glass anode and a CMOS camera. Efficient X-ray radio-graphy has been demonstrated due to the integrated imaging approach inherent to optical readout. [...]
2023 - 4 p. - Published in : EPJ Web Conf. 288 (2023) 07009 Fulltext: PDF;
In : Advancements in Nuclear Instrumentation Measurement Methods and their Applications (ANIMMA 2023), Lucca, Italy, 12 - 16 Jun 2023, pp.07009
3.
Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors / Lisowska, M. (CERN ; IRFU, Saclay) ; Aleksan, R. (IRFU, Saclay) ; Angelis, Y. (Aristotle U., Thessaloniki) ; Aune, S. (IRFU, Saclay) ; Bortfeldt, J. (Munich U.) ; Brunbauer, F. (CERN) ; Brunoldi, M. (Pavia U. ; INFN, Pavia) ; Chatzianagnostou, E. (Aristotle U., Thessaloniki) ; Datta, J. (SUNY, Stony Brook) ; Dehmelt, K. (Jefferson Lab) et al.
The PICOSEC Micromegas detector is a~precise-timing gaseous detector based on a~Cherenkov radiator coupled with a~semi-transparent photocathode and a~Micromegas amplifying structure, targeting a~time resolution of tens of picoseconds for minimum ionising particles. Initial single-pad prototypes have demonstrated a~time resolution below 25 ps, prompting ongoing developments to adapt the concept for High Energy Physics applications, where sub-nanosecond precision is essential for event separation, improved track reconstruction and particle identification. [...]
arXiv:2407.09953.- 2024-12-10 - 9 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 1072 (2025) 170151 Fulltext: 2407.09953 - PDF; 1732afb3515e2b936d222cb357afcde6 - PDF; External link: Fermilab Library Server
4.
A Novel Diamond-like Carbon based photocathode for PICOSEC Micromegas detectors / Wang, X. (USTC, Hefei ; Hefei, CUST) ; Aleksan, R. (IRFU, Saclay) ; Angelis, Y. (Aristotle U., Thessaloniki) ; Bortfeldt, J. (LMU Munich (main)) ; Brunbauer, F. (CERN) ; Brunoldi, M. (Pavia U. ; INFN, Pavia) ; Chatzianagnostou, E. (Aristotle U., Thessaloniki) ; Datta, J. (Stony Brook U.) ; Degmelt, K. (Jefferson Lab) ; Fanourakis, G. (Democritos Nucl. Res. Ctr.) et al.
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. [...]
arXiv:2406.08712.- 2024-08-12 - 15 p. - Published in : JINST 19 (2024) P08010 Fulltext: 806956891d4956950d85abdbaee8cf0d - PDF; 2406.08712 - PDF; Fulltext from Publisher: PDF; External link: Fermilab Library Server
5.
Observation of strong wavelength-shifting in the argon-tetrafluoromethane system / Amedo, P. (Santiago de Compostela U., IGFAE) ; González-Díaz, D. (Santiago de Compostela U., IGFAE) ; Brunbauer, F.M. (CERN) ; Fernández-Posada, D.J. (Santiago de Compostela U., IGFAE) ; Oliveri, E. (CERN) ; Ropelewski, L. (CERN)
We report the scintillation spectra of Ar-CF$_4$ mixtures in the range 210-800~nm, obtained under X-ray irradiation for various pressures (1-5~bar) and concentrations (0-100%). [...]
arXiv:2306.09919.
- 27 p.
Fulltext
6.
Transforming a rare event search into a not-so-rare event search in real-time with deep learning-based object detection / MIGDAL Collaboration
Deep learning-based object detection algorithms enable the simultaneous classification and localization of any number of objects in image data. [...]
arXiv:2406.07538.
- 24.
Fulltext
7.
Single channel PICOSEC Micromegas detector with improved time resolution / Utrobicic, A. (Boskovic Inst., Zagreb) ; Aleksan, R. (IRFU, Saclay) ; Angelis, Y. (Aristotle U., Thessaloniki) ; Bortfeldt, J. (Munich U.) ; Brunbauer, F. (CERN) ; Brunoldi, M. (Pavia U. ; INFN, Pavia) ; Chatzianagnostou, E. (Aristotle U., Thessaloniki) ; Datta, J. (SUNY, Stony Brook) ; Dehmelt, K. (Jefferson Lab) ; Fanourakis, G. (American Coll. of Greece) et al.
This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving stability, reducing noise, and ensuring signal integrity to optimize timing performance. [...]
arXiv:2406.05657; FERMILAB-PUB-24-0499-CMS-V.- 2024-12-16 - 29 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 1072 (2025) 170127 Fulltext: 2406.05657 - PDF; 9799b01fc06dbef84710538b6ae3d6d9 - PDF; External link: Fermilab Library Server
8.
Spatial resolution improvements with finer-pitch GEMs / Flöthner, K.J. (CERN ; Bonn U., HISKP) ; Scharenberg, L. (CERN) ; Brask, A. (Aarhus U. (main) ; CERN) ; Brunbauer, F. (CERN) ; Garcia, F. (Helsinki Inst. of Phys.) ; Janssens, D. (CERN) ; Ketzer, B. (Bonn U., HISKP) ; Lisowska, M. (CERN ; U. Paris-Saclay) ; Muller, H. (CERN ; Bonn U.) ; Oliveri, E. (CERN) et al.
Gas Electron Multipliers (GEMs) are used in many particle physics experiments, employing their 'standard' configuration with amplification holes of 140 um pitch in a hexagonal pattern. However, the collection of the charge cloud from the primary ionisation electrons from the drift region of the detector into the GEM holes affects the position information from the initial interacting particle. [...]
arXiv:2406.05836.- 2024-07-24 - 11 p. - Published in : JINST 19 (2024) P07027 Fulltext: 2406.05836 - PDF; document - PDF;
9.
Annual Report 2023 and Phase-I Closeout / Aglieri Rinella, Gianluca
This report summarises the activities of the CERN strategic R&D programme on technologies for future experiments during the year 2023, and highlights the achievements of the programme during its first phase 2020-2023..
CERN-EP-RDET-2024-001 - 208.

10.
Characterisation of resistive MPGDs with 2D readout / Scharenberg, L. (CERN) ; Brunbauer, F. (CERN) ; Danielsson, H. (CERN) ; Fang, Z. (CUST, SKLPDE ; Hefei, CUST) ; Flöthner, K.J. (CERN ; Bonn U., HISKP) ; Garcia, F. (Helsinki Inst. of Phys.) ; Janssens, D. (CERN ; Brussels U., IIHE ; Vrije U., Brussels) ; Lisowska, M. (CERN ; U. Paris-Saclay) ; Liu, J. (CUST, SKLPDE ; Hefei, CUST) ; Lyu, Y. (CUST, SKLPDE ; Hefei, CUST) et al.
Micro-Pattern Gaseous Detectors (MPGDs) with resistive anode planes provide intrinsic discharge robustness while maintaining good spatial and time resolutions. Typically read out with 1D strips or pad structures, here the characterisation results of resistive anode plane MPGDs with 2D strip readout are presented. [...]
arXiv:2402.03899.- 2024-05-21 - 13 p. - Published in : JINST 19 (2024) P05053 Fulltext: document - PDF; 2402.03899 - PDF;

CERN Document Server : 268 Datensätze gefunden   1 - 10nächsteEnde  gehen zum Datensatz:
Sehen Sie auch: ähnliche Autornamen
69 Ropelewski, L
139 Ropelewski, Leszek
Sind Sie interessiert über neue Ergebnisse zu dieser Suchabfrage informiert zu werden?
Definieren Sie eine persönliche E-Mail-Benachrichtigung oder abonnieren Sie den RSS Feed.
Haben Sie nicht gefunden was Sie suchten? Versuchen Sie Ihre Suche auf anderen Servern:
Ropelewski, L. in Amazon
Ropelewski, L. in CERN EDMS
Ropelewski, L. in CERN Intranet
Ropelewski, L. in CiteSeer
Ropelewski, L. in Google Books
Ropelewski, L. in Google Scholar
Ropelewski, L. in Google Web
Ropelewski, L. in IEC
Ropelewski, L. in IHS
Ropelewski, L. in INSPIRE
Ropelewski, L. in ISO
Ropelewski, L. in KISS Books/Journals
Ropelewski, L. in KISS Preprints
Ropelewski, L. in NEBIS
Ropelewski, L. in SLAC Library Catalog
Ropelewski, L. in Scirus