CERN Accelerating science

Article
Title Calibration of the LHC Diamond beam loss monitors for LHC Run 3
Author(s) Morales Vigo, Sara (CERN ; Cockcroft Inst. Accel. Sci. Tech.) ; Salvachua, Belen (CERN) ; Welsch, Carsten (Cockcroft Inst. Accel. Sci. Tech.) ; Zamantzas, Christos (CERN) ; Calvo Giraldo, Eva (CERN) ; Martinez Samblas, Javier (CERN) ; Wolfenden, Joseph (Cockcroft Inst. Accel. Sci. Tech.) ; Gonzalez-Berges, Manuel (CERN)
Publication 2023
Number of pages 4
In: JACoW IPAC 2023 (2023) THPL085
In: 14th International Particle Accelerator Conference (IPAC 2023), Venice, Italy, 7 - 12 May 2023, pp.THPL085
DOI 10.18429/JACoW-IPAC2023-THPL085
Subject category Accelerators and Storage Rings
Abstract A set of twelve Polycrystalline Chemical Vapour Deposition (pCVD) diamond detectors are installed in the beam injection, extraction and betatron collimation areas of the Large Hadron Collider (LHC) as fast beam loss monitoring detectors. Their high-radiation tolerance and time resolution in the order of a few ns makes them an ideal candidate to monitor bunch-by-bunch losses in the LHC beams, which have a nominal bunch separation of 25 ns. Considering their location in some of the most critical areas for beam loss studies, a signal-to-lost-particle calibration of these detectors provides a useful insight of the various LHC bunch-by-bunch beam loss mechanisms. This contribution shows the principle of the calibration of the LHC diamond Beam Loss Monitors (dBLMs) as well as a description of the machine tests run to study and perform this calibration.
Copyright/License CC-BY-4.0

Corresponding record in: Inspire


 Registre creat el 2024-01-12, darrera modificació el 2024-01-12


Text complet:
Descarregar el text complet
PDF