CERN Accelerating science

Published Articles
Title Comparative Measurement and Characterisation of Three Cryogenic Current Comparators Based on Low-Temperature Superconductors
Author(s) Tympel, Volker (Helmholtz Inst., Jena) ; De Gersem, Herbert (Darmstadt, Tech. Hochsch.) ; Fernandes, Miguel (Cockcroft Inst. Accel. Sci. Tech. ; CERN ; U. Liverpool (main)) ; Golm, Jessica (U. Jena (main)) ; Haider, David (Darmstadt, GSI) ; Kurian, Febin (Darmstadt, GSI) ; Marsic, Nicolas (Darmstadt, Tech. Hochsch.) ; Müller, Wolfgang (Darmstadt, Tech. Hochsch.) ; Neubert, Ralf (U. Jena (main) ; TLS, Tautenburg) ; Schmelz, Matthias (Inst. Photonic Tech., Jena) ; Schmidl, Frank (U. Jena (main)) ; Schwickert, Marcus (Darmstadt, GSI) ; Seidel, Paul (U. Jena (main)) ; Sieber, Thomas (Darmstadt, GSI) ; Stöhlker, Thomas (Helmholtz Inst., Jena ; Darmstadt, GSI) ; Stolz, Ronny (Inst. Photonic Tech., Jena) ; Tan, Jocelyn (CERN) ; Welsch, Carsten (Cockcroft Inst. Accel. Sci. Tech. ; U. Liverpool (main)) ; Zakosarenko, Vyacheslav (Jena U.)
Publication JACoW, 2019
Number of pages 4
In: 7th International Beam Instrumentation Conference, Shanghai, China, 9 - 13 Sep, 2018, pp.MOPC06
DOI 10.18429/JACoW-IBIC2018-MOPC06
Subject category Accelerators and Storage Rings
Abstract A Cryogenic Current Comparator (CCC) is a non-destructive, metrological-traceable charged particle beam intensity measurement system for the nano-ampere range. Using superconducting shielding and coils, low temperature Superconducting Quantum Interference Devices (SQUIDs) and highly permeable flux-concentrators, the CCC can operate in the frequency range from DC to several kHz or hundreds of kHz depending on the requirement of the application. Also, the white noise level can be optimized down to 2 pA/sqrt(Hz) at 2.16 K. This work compares three different Pb- and Nb-based CCC-sensors developed at the Institute of Solid State Physics and Leibniz Institute of Photonic Technology at Jena, Germany: CERN-Nb-CCC, optimized for applica-tion at CERN Antiproton Decelerator (AD) in 2015 with a free inner diameter of 185 mm; GSI-Pb-CCC, designed for GSI-Darmstadt with a free inner diameter of 145 mm, 1996 completed, 2014 upgraded; GSI-Nb-CCC-XD, de-signed for the GSI/FAIR-project with a free inner diame-ter of 250 mm, 2017 completed. The results of noise, small-signal, slew-rate, and drift measurements done 2015 and 2018 in the Cryo-Detector Lab at the University of Jena are presented here.
Copyright/License publication: © 2018-2024 Authors (License: CC-BY-3.0)

Corresponding record in: Inspire


 Record creato 2020-04-26, modificato l'ultima volta il 2020-05-03


Published fulltext:
Scarica documento
PDF