Página principal > CERN Experiments > LHC Experiments > ATLAS > ATLAS Preprints > Induced radioactivity in ATLAS cavern measured by MPX detector network |
Published Articles | |
Title | Induced radioactivity in ATLAS cavern measured by MPX detector network |
Author(s) | Campbell, M (CERN) ; Heijne, E (IEAP CTU, Prague ; CERN) ; Leroy, C (Montreal U.) ; Nessi, M (CERN) ; Pospisil, S (IEAP CTU, Prague) ; Solc, J (IEAP CTU, Prague ; Czech Metrology Inst., Brno) ; Suk, M (IEAP CTU, Prague) ; Turecek, D (IEAP CTU, Prague ; CESNET, Praha) ; Vykydal, Z (IEAP CTU, Prague ; Czech Metrology Inst., Brno) |
Publication | 2019 |
Number of pages | 13 |
In: | JINST 14 (2019) P03010 |
DOI | 10.1088/1748-0221/14/03/P03010 |
Subject category | Detectors and Experimental Techniques |
Accelerator/Facility, Experiment | CERN LHC ; ATLAS |
Abstract | An application of the use of MPX detectors for the measurement of induced radioactivity in the Large Hadron Collider (LHC) experiment environment is presented. The sixteen ATLAS-MPX detectors measured the associated photon ambient dose equivalent rate (H$^*$(10) rate) in ATLAS due to the LHC operation. It is presented that in 2010 the average H$^*$(10) rate determined with all MPX detectors varies around 0.015 μSv/h in the ATLAS cavern. In 2013, roughly after 50 days from the end of high luminosity physics runs, the highest H$^*$(10) rate measured with the MPX detectors has reached 14.9 μSv/h (in inner detector region). All the other dedicated MPX detectors measured H$^*$(10) rate which reached the value up to 1.3 μSv/h, depending on the MPX detector. |
Copyright/License | publication: © 2019 CERN (License: CC-BY-3.0) |