CERN Accelerating science

Article
Title Multigap Resistive Plate Chamber read out by 1×1cm2 pads with the NINO ASIC
Author(s) Liu, Z (CERN ; World Lab., Geneva) ; Kim, D W (Gangneung-Wonju Natl. U.) ; Williams, M C S (CERN ; Gangneung-Wonju Natl. U. ; INFN, Bologna ; Bologna U.) ; Zichichi, A (CERN ; INFN, Bologna ; Bologna U. ; Enrico Fermi Ctr., Rome) ; Zuyeuski, R (World Lab., Geneva ; Enrico Fermi Ctr., Rome)
Publication 2019
Number of pages 4
In: Nucl. Instrum. Methods Phys. Res., A 920 (2019) 115-118
DOI 10.1016/j.nima.2018.12.043
Subject category Detectors and Experimental Techniques
Abstract The Multigap Resistive Plate Chamber (MRPC) is a possible candidate for the Semi-Digital Hadronic Calorimeter (SDHCAL). Two 4.5×20cm2 active area MRPCs have been built to study the time resolution using the NINO ASIC as front-end electronics. The granularity of the active area is provided by a 4 × 16 array of 1×1cm2 pick-up pads. Two different designs have been used for the two chambers: a six gas gap MRPC (6-gap MRPC) with a 220μm gap size and a ten gas gap MRPC (10-gap MRPC) with a 160μm gap size. An efficiency of 95% and 97% has been reached respectively. A time resolution of 50 ps for the 6-gap MRPC and 30 ps for the 10-gap MRPC has been achieved. The multiplicity study of this two MRPCs shows that a large fraction of the single hit is recorded in the events (71% for 6-gap MRPC and 64% for 10-gap MRPC).
Copyright/License publication: © 2018 The Authors (License: CC-BY-4.0)

Corresponding record in: Inspire


 Datensatz erzeugt am 2019-03-05, letzte Änderung am 2022-08-10


Fulltext from Publisher:
Volltext herunterladen
PDF