Hlavná stránka > CMS Collection > CMS Preprints > Commissioning of the CMS Cryogenic System After Final Installation in the Underground Cavern |
Article | |
Report number | CERN-ATS-2010-014 |
Title | Commissioning of the CMS Cryogenic System After Final Installation in the Underground Cavern |
Author(s) | Dupont, T (CERN) ; Courty, J C (Air Liquide, Sassenage) ; Perinic, G (CERN) |
Publication | 2010 |
Imprint | 04 Jan 2010 |
Number of pages | 9 |
In: | AIP Conf. Proc. 1218 (2010) 3-10 |
In: | Cryogenic Engineering Conference and International Cryogenic Materials Conference, Tucson, AR, USA, 28 Jun - 2 Jul 2009, pp.3-10 |
DOI | 10.1063/1.3422381 |
Subject category | Accelerators and Storage Rings |
Accelerator/Facility, Experiment | CERN LHC ; CMS |
Abstract | After having served for the surface tests of the Compact Muon Solenoid (CMS) magnet, the cold box and ancillaries of the CMS helium refrigerator have been dismantled, moved and re-installed in the USC55 cavern in 2007. The full re-commissioning in the cavern has been followed by several tests of the refrigerator to confirm its nominal performance before it was used for the magnet and detector tests in 2008. During these tests the safety modes of the refrigeration system have been tested and improved. After a nine-year project both, the magnet and the refrigeration system are now ready for the CMS operation. |