210-87-Pr-Pid-00003 - 01 - Piping and Instrumentation Diagram Riser Platform Rt2 Closed Drain System

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

CLASSIFICATION : INTERNAL

1 2 3 4 5 6 7 8 9 10 11 12

GENERAL NOTES:
ITEM 210-V8701 ITEM 210-P8701 ITEM 210-P8702 1. REFER TO DRAWING NO. 200-20-PR-PID-00001 TO 00024 FOR STANDARD
SERVICE CLOSED DRAIN DRUM SERVICE CLOSED DRAIN TRANSFER PUMP SERVICE CLOSED DRAIN PUMP (FUTURE) PIPING AND INSTRUMENTATION DETAILS.
2. PERSONAL PROTECTION BARRIER (CAGE TYPE) TO BE PROVIDED FOR
ID, mm x LENGTH T/T, mm 1300 x 3000 OPERATING FLOW, m³/hr 6.200 01 OPERATING FLOW, m³/hr 4.73 PIPING LOCATED WITHIN 0.8 M HORIZONTALLY AND 2 M VERTICALLY
ABOVE NORMAL WALKWAY WORK AREA.
DESIGN PRESSURE, barg FULL VACUUM / 6.9 RATED FLOW, m³/hr 6.200 RATED FLOW, m³/hr 4.73 01
3. ALL MANUAL VALVE TAGS, SPECTACLE BLIND TAGS, BLIND AND SPACER
A
DESIGN TEMPERATURE, °C -29 / 94 INLET TEMPERATURE (MIN / MAX), °C 6 / 85 INLET TEMPERATURE (MIN / MAX), °C 6 / 85 TAGS SHALL BE PREFIXED WITH PLANT CODE 210 UNLESS SPECIFIED. A
OPER PRESSURE, barg 0.001 / 0.014 SG @ T&P (MIN / MAX) 0.780 / 1.018 SG @ T&P (MIN / MAX) 0.73 / 1.02 4. INSTRUMENT TAG NUMBER FOR NON-PACKAGE ITEM REGISTERED IN TMS
OPER TEMPERATURE, °C 6 / 85 VAPOR PRESSURE @ T&P, bara 0.010 / 1.010 VAPOR PRESSURE @ T&P, bara 0.01 / 1.01 (TAG MANAGEMENT SYSTEM) WILL UTILIZE PACKAGE ID OF "0” RATHER
-29 94 1 : 200 MATERIAL ALLOY 625 VISCOSITY @ T&P (MIN / MAX), cP 0.52 / 1.46 VISCOSITY @ T&P (MIN / MAX), cP 0.52 / 1.46 THAN A SPACE IN BETWEEN UNIT NUMBER AND SEQUENCE NUMBER.
DR210870001-4(A25B)2(85) 85 SLOPE
TRIM DR210870050(A34A)2(85) RATED DIFFERENTIAL PRESSURE, bar 4.7 RATED DIFFERENTIAL PRESSURE, bar 136.4
9669 210-87-PR-PID-00004 01
6.9 REMARKS DRIVER , kW 5.5 01 DRIVER , kW 75.00 01
FROM CLOSED DRAIN 01 MATERIAL ALLOY 625 MATERIAL ALLOY 625 NOTES:
HEADER 1. CLOSED DRAIN DRUM HIGH HIGH LIQUID LEVEL WILL TRIP OPEN DRAIN
VENT TO REMARKS REMARKS
TANK OIL PUMP (210-P8704).
SAFE LOCATION 210SP
2. A FLANGE CONNECTION WITH FULLY RATED BLIND LOCATED AT BOAT
NOTE-24 01 LANDING FOR CLOSED DRAIN DRUM DRAINING DURING MAINTENANCE.
87 03C
01 3. DELETED.
2" 4. PUMP 210-P8701 TO BE TRIPPED BASED ON HGH HIGH LIQUID
-29 94 1 : 200 SF210870029-2(A34A)2(85) 1 : 200
QV870066 -89 100
01 LEVEL OF CLOSED DRAIN DRUM RT-2.
DR210870002-4(A25B)2(85) 85 SLOPE SLOPE
85 SF210870019-2(A34A)2(85)
1304 210-87-PR-PID-00004 9774 210-87-PR-PID-00001 5. DELETED.
6.9 6.9 6. PURGE / FLUSHING CONNECTION.
FROM CLOSED DRAIN LO FB TO LP FLARE HEADER

SLOPE
HEADER 0.75" NC 7. THE PURPOSE OF CLOSED DRAIN DRUM IS TO COLLECT HYDROCARBON

1 : 200
B CONDENSATE FROM TOPSIDE PIPING AND PIG LAUNCHER / B
Vv870013 RECEIVER AFTER DEPRESSURIZATION.
8. SDV IS NORMALLY CLOSED LOGIC SHALL BE ESTABLISHED SO THAT SDV
-29 85 01 WILL OPEN 10 SECONDS BEFORE PUMP START AND CLOSED ON PUMP
OW210870008-2(A1E)N 49 1 : 200

QV870068
8433 210-87-PR-PID-00005 01 NOTE-20 STOP AFTER 5 SECONDS TIME DELAY.
LC SLOPE DR210870034-3(A34A)2(85)
NO POCKET 6.9 9. LIQUID FROM CLOSED DRAIN TO BE ROUTED TO EXISTING

2"
FROM OPEN DRAIN TANK FB
CLOSED DRAIN SYSTEM. WHEN CLOSED DRAIN PUMP IS INSTALLED,
OIL PUMP (210-P8704) NOTE-20 LIQUID CAN BE ROUTED TO PRODUCTION HEADER FOR FLEXIBITLITY.

NOTE-22
210SP 210UZ

3"x2"
10. DELETED.

DR210870020-3(A34A)2(85)
87 03N 210PG 87 301 11. DELETED.
01 12. LOGIC TO BE CONFIGURED SUCH THAT CLOSED DRAIN PUMP (210-P8702)
51 033

DR210870035-2(A34A)2(85)
01 CAN ONLY BE STARTED AFTER CLOSED DRAIN TRANSFER PUMP
SB8706

SB8707

SB8708

SB8709
Vv870009
(210-P8701) IS RUNNING.(TO BE FINALIZED DURING FUTURE DEVELOPMENT)
01

NOTE-21
DETAIL #2

RS
2" NC 13. LOGIC TO BE CONFIGURED SUCH THAT THE CLOSED DRAIN PUMP
2"-300# 210SDV (210-P8702) WILL BE TRIPPED IF CLOSED DRAIN TRANSFER PUMP
K1A N2 01 +
(210-P8701) IS TRIPPED.(TO BE FINALIZED DURING FUTURE DEVELOPMENT)
DETAIL #9 K2A N9 N1 N5 N6 N10 N8 49 041
2"-300# 2"-300# -29 94 14. DELETED.
C 210LT 210LG DR210870058-2(A25B)2(85) 85 DR210870059-2(A25B)2(85) 15. DIAPHRAGM RUPTURE DETECTION. C
1030 210-23-PR-PID-00007 16. CLOSED DRAIN DRUM IS SLOPPED ACROSS THE WIDTH TO
50 008 50 008 01 210-V8701 6.9
01 01 FC FV TO RT CLOSED DRAIN IMPROVE COMPLETE DRAINAGE. NOZZLE N3 SHALL BE
CLOSED DRAIN DRUM

1 : 200
SLOPE
HHLL : 1130 mm TSO HEADER LOCATED AT THE LOWEST POINT OF DRUM SLOPE.
DETAIL #12C

DR210870039-3(A25B)2(85)
HLL : 795 mm M1 NOTE-7 01 PSET = 6.60 barg 01 NOTE-9 17. DRAIN CONNECTION TO BE EQUIPPED WITH A LIQUID SEAL AND DRAIN
210LT LLL : 550 mm 24" 3" LO CHECK VALVE BOX WILL BE PROVIDED WITH MESH AT THE DRAIN POINT.

94
01
49 008 LLLL : 400 mm QV870067 FB FAILURE 18. DRAIN LINES SHOULD DRAIN BY GRAVITY TO THE CLOSED DRAIN DRUM
NO POCKETS.

6.9
49
0.75"
2" 210PSV 19. HIGH AND LOW TEMPERATURE PREVENTS START OF 210-P8701 AND
2" Vv870014
+
QV870059

-29
VX870010 2"-300# 2"-300# 2"-300# 51 043 210-P8702.
NOTE-6

N7 K2B K1B N11 NC 20. TIE-IN POINT PROVISION FOR FUTURE CLOSED DRAIN PUMP AND
210UZ 210UZ
210YA FUTURE PSV CONNECTION. IT SHALL BE PROVIDED WITH FULLY
87 305 87 301 LC N4
0.75" 2" 0.75" RATED BLIND FLANGE.
MM

1 : 200
150

NC NOTE-16 N3 QV870054 LO 49 055


NOTE-1 Vv870024 SLOPE
Vv870010 21. THE PRELIMINARY DESIGN CONFIGURATION IS SHOWN FOR FUTURE
SB8710 SCOPE. DETAILED DESIGN FOR FUTURE SCOPE SHALL BE FINALIZED
DR210870038-2(A25B)N QV870055 NC BY COMPANY FUTURE PROJECT AS APPLICABLE.
2" NC 210RODR
01 BLOCKED OUTLET
FREE DRAINING

1"
+
RUNNING 22. VALVE 210-QV870068 TO BE "LO" ONLY IF RT LP FLARE KO DRUM 01

1 : 200
210LAHH 210LALL 51 020 01

SLOPE
01 PSET = 233.70 barg 01 (RT-V-8402) UNDER MAINTENANCE OR INSPECTION.
210TT 210UZ 210YZ49 055 210XL
D 49 008 49 008 23. PU CLOSED DRAIN TANK (PT-V8714) HIGH LIQUID LEVEL ALARM D

QV870063
50 055 A

94
50 022 NC RUNNING LO 210PSV (LAH-5171) STOPS RT-2 CLOSED DRAIN TRANSFER PUMP (210-P8701)
SB8711

FB LOCAL/ +

2"
NC 51 044 TO PREVENT PU PROCESS SHUTDOWN DUE TO HIGH-HIGH LIQUID
2" 01

6.9
85
-29 94 210YA 210XL 0.75" REMOTE 3" LEVEL (LSHH-5171) TRIP IN CLOSED DRAIN TANK (PT-V8714).
01 85 DR210870003-3(A25B)2(85) 49 052 50 052 A QV870060
Vv870011 210XL 24. VENT LOCATION SHALL COMPLY WITH REQUIREMENT IN VENT

-29

FV
6.9

QV870064
H REGISTER (DOC. NO. 200-20-SH-LIS-00006).
NOTE-19 210TI FV 210UZ NC 50 055 B
LO 01
QV870051

01 3" LO START LO

2"
50 022 FB 1" 87 301 NC FB

DR210870005-2(A25B)2(85)
L 0.75"
LOW POINT

210HS
210UZ TRIP HOLDS:

DR210870060-2(A25B)2(85)
210UZ Vv870008 210PAHH 210PALL
50 055 A
01 DETAIL #8 NC 87 302 87 306 49 010 49 010 1. DELETED.
3" LO 2. DELETED.
FB STOP

NOTE-21
PC 3. DELETED. 01

210YZ49 052
210HS

DR210870032-2(F25B)2(85)
H 4. DELETED.

SLOPE
DCS 03 210PI
H ON/OFF START 210HS 50 055 B 5. DELETED.
210LIC I
50 021 0.75" 01 6. DELETED.
50 008 50 052 A 01 L
QV870061 210PI H 210UZ 210UZ 7. DELETED.
FREE DRAINING

L DR210870061-0.75(A25B)2(85) PULSATION
E QV 1 210UZ 50 020 8. DELETED. E
H 87 " DAMPENER
210HS STOP

NOTE-21
210PDI 210PDT 210SP 00 LOCAL/REMOTE 9. DELETED.
52 NC 10. DELETED.
50 019 50 019 50 052 B NOTE-12, 13

SLOPE
87 04B 210XL
M PULSATION
M 210PI HH

QV870062
NC 50 052 B 210PG 210PT 210PT 210PT 210PT
LO DAMPENER

2"
01 51 035 50 021 49P055 49P055 50 020 49 010
NOTE-12, 13 LOW POINT
DR210870004-2(A25B)2(85)
NOTE-15
STOP NOTE-23 2" 2" 2"
1958 49450-PT-PR-4128 2"x1" VX870009 QV870058 QV870057
3"x2" N1 N2 1" RS 01
LAH-5171 FROM PU CLOSED 8407 210-23-PR-PID-00003
DRAIN TANK (RT-V8714) RS 2" N3 NOTE-20 RS RS
0.75" LOW POINT LC LO FB TO PRODUCTION
NOTE-23 01 NOTE-17
0.75" FB 1" 0.75" NC MANIFOLD NOTE-9
01 DR210870003-3(A25B)2(85) N4 NC 01 NC DR210870031-2(F25B)2(85)
QV870053 QV870056 210-P8702
Vv870007 NOTE-21
210-P8701 -29 94
CLOSED DRAIN PUMP (FUTURE)
CLOSED DRAIN TRANSFER PUMP 01
85 DR210870043-0.75(A25B)2(85) DWG NO. TITLE
F
F 6.9 01 DR210870030-2(F25B)2(85) REFERENCE DRAWINGS
FV NOTE-21 01
DR210870042-0.75(A25B)2(85) 2" 01 APPROVED FOR CONSTRUCTION GP WA FA 13/04/23
NOTE-20 MIN.
-29 94 -29 94 QV870065
DR210870028-2(A25B)2(85) 00 APPROVED FOR CONSTRUCTION GP WA FA 07/04/22
85 85 DR210870928-2(A25B)2(85)
NOTE-2 ISSUED FOR APPROVAL
6.9 6.9 C GP WA FA 04/02/22
FV 1"x0.75" FV NC
B ISSUED FOR HAZOP GP WA FA 11/11/21
0.75" NC
A ISSUED FOR REVIEW GP WA FA 09/07/21
01 Vv870012
NO. DESCRIPTION BY CHKD APVD DATE
01
REVISIONS
1"x0.75"

DATE DRN DSGND CHKD APVD APVD


FREE DRAINING DR210870027-1(A25B)2(85) PROJECT TITLE :
210-97-PR-PID-00001 2243
210PC-23 DR210870063-0.75(A25B)2(85) FROM EG FLUSHING EPC for North Field Production G
BLEED
G SYSTEM Sustainability Offshore & Pipelines Project
DR210870044-1(A25B)2(85) FREE DRAINING DR210870049-1(A25B)2(85)
210-87-PR-PID-00007 2186
DRAIN COLLECTION
Qatargas Operating Company Ltd.
HEADER - DRAIN DECK THIS DOCUMENT IS PROPERTY OF QATARGAS. THIS DRAWING OR MATERIAL DESCRIBED THEREON MAY NOT BE COPIED
OR DISCLOSED IN ANY FORM OR MEDIUM TO THIRD PARTIES, OR USED FOR OTHER THAN THE PURPOSE FOR WHICH
QATARGAS IT HAS BEEN PROVIDED, IN WHOLE OR IN PART IN ANY MANNER EXCEPT AS EXPRESSLY PERMITTED BY QATARGAS.

CONSULTANT / CONTRACTOR :

01
CLOSED DRAIN DRUM CURBED AREA
Saipem S.p.A.
NOTE-17 CONTRACTOR DRAWING NO. : 033727-G-D-12-SPM-PR-D-00110-0001
01 1 : 100
SLOPE OW210870055-2(A1E)N
1607 210-87-PR-PID-00002 TITLE :
TO BOAT LANDING PIPING AND INSTRUMENTATION DIAGRAM
RISER PLATFORM RT2
H CLOSED DRAIN SYSTEM H
6 85 1 : 100

49 SLOPE OW210870023-2(A1E)N
8764 210-87-PR-PID-00002
3.5 SCALE : NTS PROJECT NO. : LTC/C/NFP/4382/19
TO BOAT LANDING
PROJECT DRAWING NO. SHT SIZE REVISION

033727 210-87-PR-PID-00003 0001 A1 01

1 2 3 4 5 8 9 10 11 12