Examining Mycofiltration Efficacy in A First Order Stream
Examining Mycofiltration Efficacy in A First Order Stream
Examining Mycofiltration Efficacy in A First Order Stream
Spring 5-14-2021
Recommended Citation
Davis, Lacey J., "Examining Mycofiltration Efficacy in a First Order Stream." Thesis, Georgia State
University, 2021.
doi: https://doi.org/10.57709/22653283
This Thesis is brought to you for free and open access by the Department of Geosciences at ScholarWorks @
Georgia State University. It has been accepted for inclusion in Geosciences Theses by an authorized administrator
of ScholarWorks @ Georgia State University. For more information, please contact [email protected].
EXAMINING MYCOFILTRATION EFFICACY IN A FIRST ORDER STREAM
by
LACEY J. DAVIS
ABSTRACT
Bacterial contamination from sanitary and combined sewer overflows, leaking sewer
infrastructure, and stormwater runoff decreases urban surface water quality. This research
contamination in first-order urban streams, which has previously been demonstrated to work in
lab experiments. The objectives are: (1) establish the spatial distribution of E. coli in the Upper
South River watershed, and (2) evaluate the potential for Trametes versicolor fungal spawn to
decrease E. coli concentrations when accounting for short hydrologic retention and surface
water-groundwater interactions inherent in streams via a stream table experiment. The Trametes
versicolor mycofilter overall reduced concentrations of E. coli, but no more than was reduced by
stream sediments alone. These findings suggest the usefulness of mycofiltration may be limited
by decreased contact time or hyporheic flow paths that bypass the mycelium installation.
by
LACEY J. DAVIS
Master of Science
2021
Copyright by
Lacey Jon Davis
2021
EXAMINING MYCOFILTRATION EFFICACY IN A FIRST ORDER STREAM
by
LACEY J. DAVIS
Christine Stauber
May 2021
iv
DEDICATION
I dedicate this thesis to my grandparents, Sherry and Larry Binenfeld, for their
unconditional love, and confidence in me. I would like to also dedicate this work to my mother,
Laura Elaine Binenfeld Negelow Davis Aven, and my sister, Laina Rachel Davis, who are my
ACKNOWLEDGEMENTS
I would like to first acknowledge my thesis advisor, Dr. Sarah Ledford, for her consistent
support, guidance, and confidence in me. I would also like to acknowledge my committee, Dr.
Richard Milligan and Dr. Christine Stauber, for their contributions to the expansion and
refinement of this thesis. Additionally, I would like to thank Dr. Christy Visaggi for her
friends: Maggie, Eleanor, Margaret, Sara Ann, Natalie, and my sweetheart, Mara, whose
enduring love provides me the bearings to navigate this ever-changing world. I love you all very
TABLE OF CONTENTS
ACKNOWLEDGEMENTS ........................................................................................................ V
1 INTRODUCTION............................................................................................................. 1
1.1.1 Overview of SSOs and CSOs in the Upper South River ......................................... 4
2 BACKGROUND ............................................................................................................. 15
3 METHODS ...................................................................................................................... 21
4 RESULTS ........................................................................................................................ 33
5.2 Conclusion................................................................................................................... 44
REFERENCES ....................................................................................................................... 46
viii
LIST OF TABLES
Table 7 E. coli and Total Coliform data for each sample site....................................................... 35
LIST OF FIGURES
Figure 2. Headwaters of the Upper South River are a milky white color due to leachate from a
historical cotton processing plant and is designated a class 1 hazardous waste site........... 4
Figure 3 GA EPD's Watershed Protections Branch Monitoring Stations on the Upper South River
Figure 12 E. coli concentrations in the Upper South River (Note: Because the Tift Site was
Figure 13 E. coli concentrations every hour for the experiment with bleached sediment and E.
coli-free inflow. Error bars indicate the standard deviation of three outflow samples taken
Figure 14 E. coli concentrations every hour for the experiment with bleached sediment and E.
Figure 15 E. coli concentrations every hour during the experiment with E. coli-spiked input
water but no mycelium. Triplicate samples were collected of the initial inflow
Figure 16 E. coli concentrations every hour during the experiment with E. coli-spiked input
water but no mycelium on a Log10 scale. Triplicate samples were collected of the initial
Figure 17 With Turkey Tail (Trametes versicolor) mycelium. Triplicates were collected of the
input concentrations, shown at time 0, with the standard deviation shown in the error
bars. ................................................................................................................................... 40
Figure 18 With Turkey Tail (Trametes versicolor) mycelium on a Log10 scale. Triplicates were
1 INTRODUCTION
Urbanization poses threats to the integrity of water quality throughout the United States
primarily due to increased impervious surfaces and associated stormwater runoff, decrease in
(Alder, 2013; Burns et al., 2005; Gaffield et al., 2003). Various research has shown that
impervious surfaces not only increase flood peaks and runoff volume, but also transmit bacterial
and chemical pollutants into surface waters at rapid rates (Fig. 1; DeWalle and Swistock, 2000;
Coupling climate change issues with continued population growth exacerbates already
mounting urban water quality issues through the United States, and in particular, in the rapidly
expanding metro Atlanta area (DeWalle and Swistock, 2000; EPD, 2008; Gaffield et al., 2003).
By 2050, population growth in the city of Atlanta is anticipated to almost double (Jeong et al.
2018). Dekalb County, in southeastern metro Atlanta is expecting a population increase of 22%
by the year 2040 (ARC, 2015). This escalated population growth will add strain to an already
aging water infrastructure system and be exacerbated by increased frequency and intensity of
precipitation events likely contributing to increased stormwater runoff, sanitary sewer overflows
(SSOs) and decreased water quality in the coming years (EPD, 2008). Conservative climate
change predictions expect an overall increase of precipitation in certain areas across the United
States (Jeong et al., 2018). Evidence is already being seen, with Dekalb County experiencing its
the third wettest year in 30 years in 2020, with over 60 inches of precipitation (Champion, 2020).
More than 6,000 streams across Georgia are considered impaired and do not meet current
water quality standards (EPD, 2008). Numerous contaminants ranging from heavy metals,
increased sediment loads, and pesticides and fertilizers threaten water quality in the Atlanta area,
2
but bacterial contamination in surface water is the largest water quality issue to manage in
Georgia (EPA, 2004; GAAS, 2014). According to the Georgia Environmental Protection
Division, over half of stream impairments in Georgia’s surface waters are caused by bacterial
contamination caused by Escherichia coli and Total Coliform (EPD, 2008). These bacteria are a
naturally occurring part of human and animal digestive systems and found in both human and
animal waste (EPA, 2004). They enter urban waterways through leaking sewer infrastructure,
SSOs, combined sewer overflows (CSOs), and stormwater runoff (EPA, 2004; GAAS, 2014).
Although the consequences of bacterial contamination on water quality are well researched, they
remain a significant source of water quality degradation throughout the United States and the
metro Atlanta area and continue to pose numerous human health risks (EPA, 2016; Walsh et al.,
2005). Understanding ways to remove bacterial contamination from urban streams is required to
improve stream health and access to recreation for citizens. This thesis presents the results of an
investigation into the effectiveness of mycofiltration for E. coli removal in a first-order Piedmont
stream as well as the past and current E. coli contamination in the Upper South River.
The South River is located on Muscogee Creek Indigenous Peoples land (NLD, 2020)
and is part of the Upper Ocmulgee River Basin. Today, the South River provides drinking water
supplies to Clayton, Henry and Rockdale Counties (SRWA, 2020; USGS, 2020). It originates in
highly urbanized South Atlanta (Figure 2) and flows southeast through DeKalb, Fulton, Jasper,
Newton, Rockdale, and Clayton counties until it converges with the Alcovy River and the
Yellow River draining into Lake Jackson (ARK, 2020; SRWA, 2020; USGS, 2020). The outlet
of Lake Jackson marks the beginning of the Ocmulgee River which continues to flow southeast
until it merges into the Oconee River (ARK, 2020; SRWA, 2020; USGS, 2020). Finally, the
Oconee River joins the Altamaha River which continues eastward ultimately draining into the
Atlantic Ocean (ARK, 2020; SRWA, 2020; USGS, 2020). Overall, the South River watershed
contains about 60 tributaries and is comprised of land use ranging from agricultural, residential,
commercial, and industrial (Scott, 2014; USGS, 2020). The Upper South River has an extensive
history and continued issues with bacterial contamination as a result of failed regulatory
enforcement and failing infrastructure (Mitchell, 2019; SRWA, 2020; USACE, 2012). This
section aims to (1) provide an overview of Combined Sewer Overflows (CSOs) and Sanitary
Sewer Overflows (SSOs) in Dekalb County, and (2) frame the following mycofiltration lab
Figure 2. Headwaters of the Upper South River are a milky white color due to leachate
from a historical cotton processing plant and is designated a class 1 hazardous waste site.
In urban areas, storm sewers and sanitary sewers are the primary categories of sewer
systems (EPA, 2004; EPA, 2016). Storm sewer systems carry stormwater runoff directly into
surface waters, while sanitary sewer systems are responsible for transporting untreated sewage
(domestic, commercial and industrial) to wastewater treatment facilities for treatment (EPA,
2004; EPA, 2016; USGS, 2020). Sanitary sewers can be further categorized as separate or
combined. The City of Atlanta has historically operated with numerous combined sewer systems
(CSS) which- unlike separate sewer systems (SSS) are constructed to carry stormwater runoff
and sewage in one combined piping system, and are designed to overflow during the highest
precipitation events as a preventative measure against pipe breakage (Borden, 2015; SRWA,
5
2020). During high precipitation events (and subsequent high stormwater collection) CSS can
result in CSOs and subsequent high concentration of E. coli may enter the surface water (EPA,
2004). Due to the 1,925 CSOs that occurred between 1988-1991 in the South River and
Chattahoochee River, the City of Atlanta was required to eliminate CSOs through the Georgia
Water Control Act (Borden, 2015). However, the Custer Ave CSO facility and the Intrenchment
Creek Water Quality Control Facility remain on the South River and continue to threaten water
In contrast, Sanitary Sewer Overflows (SSOs) generally result from fats, oil, and grease
clogs, aging Wastewater Collection Transmission System (WCTS) and resulting high stormwater
intrusion (the infiltration of precipitation through damaged sewer infrastructure), root intrusion,
lack of maintenance, and population growth (USDC, 2010; CRK, 2014; DWM, 2015; EPA,
2016). Unlike the City of Atlanta, Dekalb County only has SSS and therefore only experiences
SSOs. Between the years 2006 and 2010, Dekalb County experienced at least 2,846 SSOs
(USDC, 2010) and 836 raw sewage spills directly into Snapfinger Creek, and other tributaries to
Both CSOs and SSOs result in the discharge of untreated sewage, wastewater, and
stormwater directly into surface water (Borden, 2015; CRK, 2014; EPA, 2004; EPA, 2016).
Because of this, CSOs and SSOs pose risks to public health and water quality, and both are
considered point source discharges regulated by the EPA and EPD through the Clean Water Act
(CWA) and associated National Pollutant Discharge Elimination Permits (NPDES) permits
(EPA, 2004; EPA, 2016). SSOs and CSOs cause numerous and varied environmental impacts
such as decreases in dissolved oxygen and resulting decrease in aquatic abundance and diversity,
6
excessive nutrient loads and resulting eutrophic conditions, and entanglement or digestion of
Water quality in the United States is primarily regulated by the CWA (Borden, 2015;
EPA, 2016; Pennington and Cech, 2010). The CWA was signed into law in 1972 to provide a
regulation of pollutant discharges in surface and groundwater throughout the United States
(Borden, 2015; Pennington and Cech, 2010). Essentially, the CWA states that a point source
pollutant can only be discharged into a waterway with the use of permit, and this is enforced by
the EPA and EPD through the use of NPDES permits (Borden, 2015; Doyle, 2012). Although
NPDES permits specify the quantity and type of pollutants allowed for discharge in surface and
groundwater, (Doyle, 2012; Martinez, 2016; Pennington and Cech, 2010), Dekalb County has
continuously failed to meet these requirements and thus violated the CWA (USDC, 2010).
As a result of years of noncompliance with the federal CWA and the GA Water Quality
Control Act, primarily due to excessive sewage spills, the EPA filed a lawsuit against Dekalb
County in 2010 (USDC, 2010). This lawsuit resulted in the agreement of a settlement by way of
a consent decree between Dekalb County, the EPA, and EPD (EPA, 2015; USDC, 2010).
Specific violations charged to Dekalb County include the “illegal discharges of untreated
sewage” and failure “to operate and maintain the collection and transmission systems of its
treatment works” (EPA, 2017). The resulting 2011 consent decree demanded that Dekalb County
repair and update its WCTS in the South River, Snapfinger Creek and Peachtree Creek in order
to reduce its annual SSOs and CSOs within nine years as well as pay almost $900,000 in civil
According to the consent decree, 64% of the Dekalb County’s WCTS infrastructure is
between 25-50 years old and in need of replacement (USCD, 2010). Dekalb County Department
7
of Watershed Management (DWM) has developed a rehabilitation plan to limit SSOs (DWM,
2015). Intended rehabilitation methods include techniques such as “cured-in-place line pipe, pipe
bursting, manhole lining, manhole replacement, manhole height adjustment, manhole ring and
cover replacement, manhole frame sealing, open cut pipe replacement, point repairs, manhole
raising, manhole ring and cover replacement, and service lateral rehabilitation” (DWM, 2015).
These rehabilitation methods are intended to reduce pollutants as required by the consent decree
yearly as follows: “Total Suspended Solids (TSS) reduced by 9,743 pounds, Biological Oxygen
Demand (BOD) reduced by 9,424 pounds, Chemical Oxygen Demand (COD) reduced by 22,133
pounds, Total Nitrogen reduced by 1,437 pounds, Total Phosphorous reduced by 272 pounds”
(EPA, 2015). These improvements to Dekalb County’s WCTS are estimated to cost over $1
billion (News Release, 2020). Although the consent decree requires repairment of one-third of
Dekalb County’s sewer infrastructure, it does stipulate repair for the remaining sections despite
The consent decree expired on June 20th, 2020; however, Dekalb County had failed to
meet the requirements of the consent decree by this date (SRWA, 2020). In fact, in 2017, 6.4
million gallons of untreated sewage spilled into Snapfinger Creek, the largest SSO in 11 years,
and within the first 9 months of 2020, Dekalb County SSOs had already resulted in over 2
million gallons of untreated sewage pouring into the Upper South River (DWM, 2020; Niesse,
2017). Due to an inability to meet the initial deadline, in October 2020, the EPA, EPD, and US
Department of Justice extended the consent decree (News Release, 2020). The new, extended
consent decree prioritizes about 100 locations in the WCTS, requires Dekalb County to increase
its reporting to the EPD and EPA, and to pay over $1 million in civil penalties to the United
States and the State of Georgia (News Release, 2020). In response to this inability to make
8
substantial change in decreasing SSOs since 2011, the SRWA filed a citizen lawsuit stating that
Dekalb County remains in violation of the CWA and NPDES permits (Mindock, 2020).
However, the lawsuit was dismissed in court by U.S. District Judge Steven D. Grimberg because
according to the court, the EPA and EPD extension of the consent decree settles the case
(Mindock, 2020).
Although the Georgia Environmental Protection Division (EPD) has monitoring locations
on the Upper South River and its tributaries (Figure 3), consistent Total Coliform monitoring is
lacking. The most recent report (2014) on the Upper South River highlights segments that do not
meet Total Coliform bacteria total maximum daily load (TMDL). TMDL is defined as the
amount of pollutant a body of water can legally contain according to the CWA and is calculated
where WLAs are the total amount of point source waste allocated, LAs are the total
amount of nonpoint source waste load allocated, and MOS refers to the margin of safety (Scott,
2014). Table 1 lists stream segments in the Upper South River that exceed the TMDL and thus
Specific causes of stream impairment in these areas are attributed to stormwater runoff,
animal waste, SSOs and CSOs, Wastewater Treatment Facilities, and septic tank failures (Scott,
2014). Unfortunately, the steps towards improving water quality in the South River by the Metro
North Georgia Water Planning District (MNGWPD) such as the creation of a Stormwater
Management Plan (SWMP), public education programs, streambank stabilization and restoration,
and sewer infrastructure repair, have not been sufficient and current SSOs and CSOs remain a
significant and escalating problem for the South River (MNGWPD, 2009; Scott, 2014; SRWA,
2020). To supplement these findings and provide a more current picture of the issue, the South
River Watershed Alliance (SRWA) began a water quality monitoring program in 2019 with the
objective of obtaining consistent water quality data such as Total Coliform and E. coli.
According to the EPA, E. coli concentrations are used as standards for determining water
quality in regard to bacterial contamination and to protect the public from contact with harmful
bacteria during recreation and/or swimming (EPA, 2016; GAAS, 2014). E. coli standards for
Recreational Waters indicate that a designated swimming area must contain <235 (cfu/100mL),
<298 (cfu/100mL) in a moderate swimming area, <410 (cfu/100mL) in a light swimming area,
and <576 (cfu/100mL) in an infrequent swimming area (GAAS, 2014). Because the South River
is not designated for recreational use, the CWA does not necessitate the above E. coli
concentration standards to be met. The South River’s designated use classification is currently
“Fishing” which is the lowest classification for surface water and affords the lowest protection in
terms of pollutant levels (SRWA, 2020). The SRWA has been working to shift the South River’s
designation to “Recreation” in order to force the EPD to implement improved water quality
standards (SRWA, 2020). And although, the state of Georgia has recognized that the need to
redraft the categories of surface water designated uses stating that “the designations for fishing
11
are not stringent enough for certain sensitive ecosystems” (EPD, 2004) no progress has been
made to execute these changes. Because the South River is unofficially utilized by residents for
recreation and fishing, higher water quality is imperative to minimize public health threats.
Although policies such as the CWA coupled with modern water treatment technologies
have enabled the majority of the U.S. population access to pathogen free water for consumption
and food production, Total Coliform and E. coli concentrations in surface water regularly exceed
safe standards (Gaffield et al., 2003). CSOs and SSOs in particular threaten public health by
exposure to untreated sewage and subsequent intestinal parasites, viruses and bacteria (EPA,
2004). Additionally, CSO and SSO consequences are exacerbated during precipitation events by
an influx of other pollutants via stormwater runoff into surface water (EPA, 2004). As discussed
preciously, bacterial contamination is the leading cause of stream impairment in the United
States and impaired segments may pose significant public health concerns (EPA, 2004).
Research indicates that nonpoint source pollution, and stormwater runoff in particular,
increases the public’s exposure to bacterial contamination and propensity for acute or chronic
illness and are directly related to increased concentrations of E. coli, Total Coliform, Giardia,
and Cryptospondium pathogens in surface water (Gaffield et al., 2003). E. coli in particular poses
problematic public health risks due to antibiotic resistance of numerous strains (Pini and Geddes,
2020). Accurate data regarding the quantity of illness related to waterborne diseases remains
elusive due to the fact that the majority of cases are unreported due to the difficulty in accurate
diagnosis; however, acute cases of waterborne illness caused by the recreational use of
bacterially contaminated water include “ear and eye discharges, skin rashes, and gastrointestinal
problems” (Gaffield et al., 2003). Immunocompromised people, children, people who are
12
pregnant, and elderly people remain the most vulnerable to serious illness as a result of such
pathogens (Gaffield et al., 2003). Additionally, the increased temperatures and increased
precipitation rates associated with climate change are likely to increase surface waterborne
illnesses which result from the recreational use of bacterially contaminated water (Gaffield et al.,
2003).
fungi for contaminant removal from water. Mycoremediation is a technique used to remove a
range of pollutants from soil and/or water (Cotter, 2014; Kulshreshtha et al., 2014). The prefix
‘myco’ refers to fungi and ‘-remediation’, in general, refers to the process of cleaning or
correcting (Cotter, 2014). Research has shown mycelium are capable of removing a variety of
chemical, heavy metal, and bacterial contaminants from terrestrial and aquatic environments
(Taylor and Stamets, 2014). Although it is a relatively new area of research, mycofiltration has
been used for remediation of polluted water due to industrial agricultural practices, animal
husbandry, and certain industrial manufacturing sites, as well as from stormwater runoff and
failing sewer systems (Cotter, 2014; Pini and Geddes, 2020; Singh, 2006; Stamets et al., 2013;
Taylor et al., 2015). Mycofiltration installations vary in scale, medium, and contaminant removal
and although mycofiltration is typically used post contamination, it can be used preventatively in
Best management practices (BMP) and green infrastructure may reduce the quantity of
infiltration and groundwater recharge; however, they may not completely remove the
contamination (Gaffield et al., 2003; Martinez, 2016). BMPs range in scale from high impact
13
infrastructures such as sand filtration, wetlands, and retention ponds, to low impact practices
such as household rainwater collection units, swales, and green roofs (DWM, 2018).
Mycoremediation may be a useful addition to the above BMPs due to its relative low cost and
minimal impact. Additionally, research has estimated that mycoremediation may be a more
affordable alternative to current wastewater treatment operations that utilize bacteria and/or
sterilization because mycoremediation (excluding biosorption) does not create byproducts (Molla
failed government regulatory enforcement and failure to improve Dekalb County’s sewer
infrastructure, but there has been limited research that considers the impact of hydrology on its
effect. As has been well observed in remediation of nutrient contamination by streams (Craig et
al., 2008; Hall et al., 2009; Bernhardt et al., 2017), the time-scale of interaction between the
remediation media and contaminants may be key in understanding the efficacy of the approach.
However, when this is accounted for, mycofiltration may be an appropriate approach for small
order urban streams. Small scale stream restoration techniques founded in environmental equity
2016). Because environmental restoration can lead to environmental injustice, in particular green
exclusion of economically vulnerable and marginalized residents (Gould and Lewis, 2016), it is
14
imperative that mycoremediation research balances attainable restoration goals with community
needs while centering community involvement (Doyle and Shields, 2012; Walsh et al., 2005). In
particular, mycoremediation may contribute to increased visibility of the water quality issues
facing the Upper South River and bolster the SRWA’s argument for improved water quality
designation.
This research will specifically answer the questions (1) How effective is Escherichia coli
(E. coli) removal from surface water when interacting with Trametes vericolor fungal spawn for
short periods of time in a laboratory representation of a first-order stream? and (2) Will
statistically significant decreases in E. coli concentrations occur when accounting for hydrologic
interactions? Initially, I hypothesized that the presence of Trametes vericolor would reduce E.
coli contamination linearly, even when the natural flowpaths and retention times of streams were
considered.
This research consisted of a lab-based experiment and field based research which
the Upper South River and evaluate the feasibility of a prototype for future mycofiltration
installations within the Upper South River Watershed. The lab-based experiment utilized a
stream table filled with sediment from Ripplewater Creek (a tributary of the Upper South River)
versicolor mycelium to mitigate E. coli concentrations in the surface water. Naturally occurring
E. coli from Ripplewater Creek was isolated, cultured, and routed through a flow rate variable
pump with deionized water at a constant rate through the stream table for 5 hours. A mycofilter
of Trametes vericolor fungal spawn and Quercus alba sawdust trimmings were deployed at one
section across the stream table, and samples were taken and analyzed with an IDEXX Quanti-
15
Tray System hourly. These results were compared to experiments where the E. coli-laced water
was run without the mycofilter. Additionally, I analyzed stream samples along the Upper South
River with the IDEXX Quanti-Tray System in order to determine spatial and temporal
installations because they help determine the best suited fungal species and substrate for the
contaminant and location, the quantity of mycofilters necessary for substantial contaminant
removal rates in relation to rate of discharge (Cotter, 2014). This study aims to provide data
applicable for future mycofiltration installations within in the Upper South River.
2 BACKGROUND
contaminants levels (Kapahi and Sachdeva, 2017; Rhodes, 2014); mycoremediation and
accomplished through a variety of mechanisms such as biosorption, where heavy metals get
heavy metals and concentrate them (Velásquez and Dussan, 2009), and biodegradation, the
(Kulshreshtha et al., 2014). It is important to note, that although biosorption (also known as
hyperacuumulation) has been shown to be an effective bioremediation tool, it does not degrade
the contaminant but merely transfers the contaminate to the fungi which then needs to be
properly disposed (Cotter, 2014; Kulshreshtha et. al, 2014). Research demonstrates that
biodegradation is the proposed mechanism for E. coli reduction through mycofiltration and this
16
benign substance and does not produce contaminated waste products (Kulshreshtha et al., 2014).
Additionally, although this research focuses on the use of mycelium to remove contamination,
past research has shown that live or dead mushrooms (the fruiting body of fungi) and even the
spent mushroom substrate can be used as for bioremediation (Kapahi and Sachdeva, 2017;
ways (Bhadouria et al., 2019; Cotter, 2014; Stamets, 2005). Mycelium have shown the ability to
interrupt cellular replication and degrade cell membranes (Cotter, 2014). Interestingly, they can
also change the pH of the surrounding environment thus making the area inhospitable to
microorganisms (Bhadouria et al., 2019; Cotter, 2014; Singh, 2006). Various chemical reactions
such as oxidation, reduction, biological degradation, and co-metabolic reactions are also
pathways towards degradation of contaminants (Bhadouria et al., 2019). Lastly, they may also
limit microbial growth by reducing nutrient availability in surrounding areas through species
exclusion, the taking up of physical space thus preventing growth of other organisms (Cotter,
2014; Singh, 2006). Mycelium are able to do all of the above through enzyme secretion, and they
can be highly effective because (unlike bacteria) they are not bound by cells and therefore they
do not require direct contact “with a compound in order to begin to degrade it” (Cotter, 2014).
This may be particularly useful in mycofiltration projects because the mycelium need only to be
in close (not direct) contact with the pathogen in order to digest it (Cotter, 2014).
Mycelium are the rooting body of fungi and are decomposers by their very nature (Cotter,
2014; Singh, 2006; Kulshreshtha, et al., 2008; Stamets, 2005). In natural systems, they secrete
17
enzymes which metabolize materials for consumption (Singh, 2006; Stamets, 2005).
Specifically, they manufacture peroxidase, cellulose, ligninase, and laccase enzymes which break
down the lignins and cellulose in woody material (Cotter, 2014; Singh, 2006; Rhodes, 2014;
Stamets, 2005). This decomposition results in humus which is a material full of more accessible
nutrients for other organisms to consume and provides an imperative role in the nutrient cycling
(Rhodes, 2013).
Mycelium can be broken down into two main groups: white rot and brown rot (Cotter,
2014; Stamets, 2005). The majority of literature regarding mycoremediation uses white rot fungi
and this is mainly due to their predication towards consuming lignin whereas brown rot fungi
generally break down cellulose (Cotter, 2014; Rhodes, 2014). White rot fungi use a variety of
enzymes and thus are able to break down and/or transform a variety of organic molecules. This
2014). Notable white rot fungal species include Pleurotus spp, Trametes versicolor, Ganoderma
lucidum (Cotter, 2014; Mir-Tutusaus et al., 2014). Certain fungi species have affinities with
temperature, substrate, biomass, and pH (Cotter, 2014; Kapahi and Sachdeva, 2017;
Various mushroom species and genera have been shown to sequester (biosorb) high
concentration of numerous heavy metals, in their mycelium as well as their fruiting bodies while
others have shown the ability to biodegrade heavy metals, hydrocarbons, and other chemical
pollutants (Kapahi and Sachdeva, 2017; Kulshreshtha et al., 2014). For example, the
18
extracellular enzymes that Pleurotus spp. (oyster mushroom) secrete have shown the ability to
degrade polymers (da Luz et al, 2013), crude oil (Olusola and Anslem, 2010) and sorb heavy
metals such as cadmium, copper, zinc, iron, lead, and nickel (Lamrood and Ralegankar, 2013;
Oyetayo et al., 2012; Tay et al., 2011). More specifically, certain species within the genus show
an affinity for certain heavy metal biosorption; for example, in previous research higher
cadmium uptake was exhibited in P. ostreatus versus higher mercury uptake by P. sajor-caju
(Kapahi and Sachdeva, 2017). A variety of other fungi species such as Lentinula edodes, Corolus
versicolor, Agaricus bisporus, Lactarius piperatus, Trametes versicolor and Fomes fasciatus
have shown degradation and biosorption of a variety of complex pollutants ranging from
Polycyclic aromatic hydrocarbons (PAHs) to a variety of heavy metals (Manna and Amutha,
Recent research has indicated that white rot fungi may be able to remediate
(Bhadouria et al., 2019; Hu et al., 2020). Trametes versicolor in particular was shown to degrade
Tutusaus et al., 2014). Additional research has shown that Trametes versicolor and other white
rot fungi have the ability to remediate certain micro pollutants which are not removed by current
WWTP operations (Álamo et al., 2018; Beltrán-Flores et al., 2020; Mir-Tutusaus et al, 2018).
ibuprofen, naproxen, salicylic acid), various antibiotics, psychiatric drugs, and endocrine
disruptors have been effectively removed or transformed from wastewater using T. versicolor
(Mir-Tutusaus et al., 2018). However, numerous limitations remain which prevent the use of
19
mycofiltration for wastewater treatment such as the need for nutrient addition to the system,
2018).
treatment plants, agricultural runoff, and stormwater retention ponds and runoff. Regardless of
the scale of the project, it is imperative to utilize the best fungal species for the contamination
(Cotter, 2014). Numerous species of fungi have shown antimicrobial properties; specifically,
Trametes versicolor (Cotter, 2014), Calvatia spp, Ganoderma spp., and Pleurotus spp (Cotter,
2014; Singh, 2006). Because this field of study is burgeoning, research remains limited;
however, field and lab studies which are foundational to the study of mycofiltration and show
Stamets (2005) details field and lab mycoremediation research in his book Mycelium
controlling bacteria contamination in surface water from agricultural runoff (Stamets, 2005). In
his field experiment, he inoculated Storpharia rugoso annulata mycelium into woodchip swales
downstream from his livestock pen and documented a 100% decrease in Total Coliform
concentrations in the effluent after one year despite an increase in livestock population (Stamets,
2005). His subsequent laboratory research (Stamets et al., 2013) with Washington State
University identified fungal species for mycofiltration, cultivation methods such as the
mycofiltration. This research identified Storpharia spp. as the preferred mycelium for
mycofiltration due to its rate of initial colonization and resilience under various environmental
20
stressors such as temperature and dehydration, and propensity at E. coli concentration reduction
(Stamets et al., 2013). Stamets et al. performed a series of single bucket tests wherein an E. coli
concentration of about 800 cfu/100mL per 30 L bucket, was percolated through a Storpharia spp.
mycelium mycofilter at a flow rate of 0.5L/min and 2.2 L/min (Stamets et al., 2013). The
mycofilters were filled with a 1:1 ratio of mycelium to large and small wood chips. Their results
indicated an E. coli reduction by about 20% at 0.5L/min flow rate and about a 14% reduction of
E. coli at the 2.2 L/min rate (Stamets et al., 2013) indicating that longer contact time between E.
coli and mycelium is necessary for efficacy. Overall, this research concluded that mycofiltration
(unlike other stormwater BMP) are capable of removing free-floating (not sediment-bound)
bacteria (Stamets et al., 2013). It is important to note, that while this research did percolate water
through the filter, it did not account for natural hydrologic conditions including hyporheic flow
the efficacy of Pleurotus ostreaus mycelium for E. coli reduction. Their research showed a 98%
reduction in E. coli concentrations after a three-week period, and importantly, indicated that
reduction increased after each subsequent week (Martinez, 2016). Thomas et al. (2015) also used
Storpharia rugoso annulata coupled with Pleurotus ostreatus, and Pleurotus ulmarius mycelium
inoculated alder mulch in bioretention cells in a human made wetland and compared those
bioretention cells with ones that only had alder mulch without mycelium inoculation. After a six-
month period, the control cells showed an E. coli reduction of 66%, and the mycelia-inoculated
cells produced an E. coli reduction of 90% (Thomas et al., 2015). The most recent research on
mycofiltration for bacterial removal focused on contact time related to E. coli removal and found
that mycelium are capable of E. coli removal up to 96 h after inoculation in a sterile lab
21
environment (Pini and Geddes, 2020). However, they note, that the efficacy of short term contact
and longer than 96 h contact is unknown (Pini and Geddes, 2020). Again, this research did not
account for hydrology; the lab inoculated and natural stream water were contained in receptacles
and did not flow as would occur in a natural stream environment (Pini and Geddes, 2020).
mycofiltration, Cotter (2014) found that while Storpharia spp may initially reduce bacterial
concentrations, long-term it may ultimately increase the bacterial concertation (Cotter, 2014).
mycoremediation in soil, Gulis and Suberkropp (2003)’s research has indicated that the enzymes
secreted by Pleurotus spp may be diluted in aquatic environments and could have limited
efficacy in mycofiltration applications. Trametes vericolor mycelia have been shown to have
antimicrobial activity in isolated laboratory studies against various bacteria including E. coli,
3 METHODS
collected to quantify the extent of E. coli contamination in the Upper South River. Sampling
locations on the Upper South River headwater, tributaries, and main stem stream segments were
identified, and all samples were obtained utilizing the Adopt a Stream Quality Assurance/Quality
Control (QA/QC) chemical and biological protocols. Each stream sample was taken at base flow,
at roughly the same time of day, and at the exact same location. Samples were analyzed at the
Chattahoochee Riverkeeper’s Neighborhood Water Watch water quality lab (CRK, 2014). Nine
22
total sample sites were located on the main stem of the Upper South River and its tributaries
(Figure 11).
Each site was chosen due to accessibility and relation to CSO and WWTP facilities. The
Tift site is located at the southern headwaters of the Upper South River. McDaniel is a tributary
to the South River and is located below the McDaniel Branch constructed wetlands near Arthur
Langford Park in SW Atlanta. SR-1 is located on the main stem of the Upper South River
adjacent to the Brownsmill Golf Course. CSO-1 is a tributary to the Upper South River and is
located upstream from Custer Combined Sewer Overflow Facility. CSO-2 is a tributary of the
Upper South River and is located downstream from Custer Combined Sewer Outflow Facility.
WWTF-1 is located on the main stem of the Upper South River upstream from the Snapfinger
Wastewater Treatment Facility. WWTF-2 is located on the main stem of the Upper South River
downstream from Snapfinger Treatment Facility. SR-2 is on the main stem of the Upper South
23
River as well at the Panola Shoals Trailhead. Lastly, Ripplewater is a tributary to the Upper
versicolor mycelium in E. coli removal from a first-order stream. A 2.5’ X 6’ stream table was
utilized to simulate a flowing stream. Sediment from Ripplewater Creek (tributary to the Upper
South River) was collected, placed in the bottom of the stream table at a 2-inch depth, and
bleached. A Geotech GeopumpTM Peristaltic DC pump was used to pump water at a constant rate
(5.2 +/- 0.28 mL/s) through the stream table. The first experiment was performed with only
deionized (DI) water to determine the baseline E. coli concentrations after sediment bleaching.
The second experiment ran DI water containing 615.85 +/- 154.72 MPN/100 mL E. coli. The
final experiment was performed with DI water containing 642.08 +/- 211.31 MPN/100mL E. coli
and one cross vein deployment of a mycofilter containing Trametes versicolor (T. versicolor)
mycelium. Each experimental setup was run three times and the system was sterilized with 10%
chlorinated DI water between runs to remove residual E. coli and subsequently flushed with 24 L
A 2.5’ X 6’ stream table was sterilized and placed on a worktable in Dr. Sarah H.
Ledford’s urban hydrology laboratory. A hydroponic filter was installed at the outflow end of the
stream table covered with landscaping fabric to mitigate sediment build up and prevent clogging
of the outflow. Ripplewater Creek sediment was collected from the streambed at 33°73'62.6" N,
-84°34'66.1" W and placed inside the steam table at a depth of 2 inches (Figure 5). Sediment was
typical of an urban piedmont streambed and consisted of a mixture of fine clay, sand, and silt
24
sediment, as well as gravel and pebbles. Pieces of broken glass, trash, and small decomposing
invertebrates were also present in the sediment. A 5-gallon bucket was placed at the head of the
stream table; a steady flow of DI water was pumped into the stream table with a Geotech
GeopumpTM Peristaltic DC pump and MasterflexTM ¼ inch ID tubing. A second 5-gallon bucket
was placed at the tail of the stream table to collect the outflow water (Figure 6). With time, a
channel formed in the sediment between the inflow and outflow points.
Sediment sterilization was achieved before each test by adding 10% bleach to 22L of DI
water and running through the system. This procedure was repeated until an initial sediment
sterilization was obtained and outflow water contained 0-3 MPN/100mL E. coli. After each
experiment, the sediment was re-sterilized until E. coli concentrations returned to low
Samples for E. coli isolation from Ripplewater Creek were collected in-situ and stored
procedures. Procedures included 1) labeling the Nasco Whirl-Pak sample bag with the current
time, date, and experiment, 2) wearing unpowered latex disposable gloves and taking samples
without touching the inside of the sample bag, 3) obtaining a minimum sample volume of
100mL, 4) placing the sample immediately in a refrigerator, 5) collecting the samples at mid-
stream, and 6) analyzing the sample within 6 hours of collection while maintaining a stable
E. coli from the sample water was isolated and cultured at GSU’s School of Public Health
in Dr. Lisa Casanova’s laboratory (Table 2, 3, 4, 5; Figure 7, 8). Cultured E. coli was stored at -
26
20 degrees C. After use, the E. coli contaminated water was neutralized with a 10% bleach
As discussed earlier, other species of mycelium such as Pleurotus spp. and Stropharia
versicolor mycelium was chosen for the experiments due to its ability to survive amid high
discharge rates (Cotter, 2014), which may be useful for in future field deployment. T. versicolor
29
cultivation is relatively simple because it colonizes on a variety of hardwood mediums and has
shown the ability to outcompete other fungi in its growth rate (Cotter, 2014). Untreated Quercus
alba sawdust trimmings were obtained from a local cabinet shop and stored in a cool, dry place
until needed. T. versicolor sawdust spawn (Cotter, 2014) was purchased from Mushroom
Mountain and kept refrigerated (38°F) until needed for incubation. The spawn is naturally white
in color (Figure 9) and has an acidic odor; no changes in coloration or odor were observed
Untreated burlap mycofilters were constructed (2” W X 14” L) based on Stamets’ (2005)
mycofilter design (Figure 10). The mycofilters were initially sterilized for 10 minutes in de-
chlorinated boiling water and then filled with a 2:1 ratio containing T. vericolor sawdust spawn
and sterilized Quercus alba sawdust weighing a total of 330.0 grams. Sawdust sterilization was
obtained by first vacuum sealing the sawdust and then placing in a 1100 W Sous Vide cooker at
178°F (Figure 11). The mycelium was then incubated at 75-85°F for 2-5 weeks in a sterilized 18-
gallon plastic bin. A heating lamp was used to guarantee consistent temperature and the
inoculated burlap mycofilters were placed in a lattice formation to allow for adequate air
circulation. Suggested incubation time for optimal mycelia efficacy is 2-5 weeks (Cotter, 2014;
Pini and Geddes, 2020). Daily misting with de-chlorinated water prevented the mycelium from
drying out. All equipment was sterilized beforehand with 190 proof Everclear. Latex gloves and
a face mask were worn while handling the mycelium, sawdust, and mycofilters.
30
A “spike” of E. coli was put into a bucket containing 12L DI water and stirred for 5
minutes to fully incorporate the E. coli, with a goal concentration of 1000MPN/100 mL. The
water in the bucket was then pumped through the stream table with the flow rate variable pump
for 5 hours, requiring 8 input buckets. Details of the dilution process and ratios displayed in
Table 6 and a sample was taken from each bucket to measure inflow E. coli concertation. Sample
water was pumped through the table at a rate of 5.2 +/- 0.28 mL/s, with the pump rate measured
at the beginning of each experiment. Water continuously flowed into 5 gallon buckets at the end
of the stream table. A sample was collected from outflow of the stream table before it entered the
lower buckets each hour for the length of the experiment. Buckets were sterilized with a 10%
Samples of the outflow were collected in Nasco Whirl-Pak and immediately placed in a
refrigerator at 4°C. Samples were prepared for the IDEXX Colilert-18 Quanti-tray system
analyzation by transferring 100mL of the sample into a 120mL sample vessels using a pipette.
Next, the IDEXX Colilert reagent powder was added to each sample and dissolved. This mixture
was then poured into Quanti-Tray/2000 and bubbles were allowed to settle. Finally, the Quanti-
Tray was sealed with the Quanti-Tray Sealer. Each sample was labeled with the date, sample
name, and dilution (no dilution was used). The sealed samples were then placed in an incubator
at 35°C for 18-22 hours. After incubation, the samples were removed and individually inspected
in natural light and using a UV-light. Results were read according to the IDEXX Coliler-18 test
Procedure (2017) and recorded on the back of the Quanti-Tray, in the lab notebook, and
ultimately onto a Microsoft Excel spreadsheet. The IDEXX Coliler-18 test is approved by the
EPA to monitor drinking water, surface water, ground water, and wastewater (CRK 2014,
IDEXX, 2017). The IDEXX Quanti-Tray using the Most Probable Number (MPN) statistical
throughout the experiment. Sterile latex gloves were worn at all times. Disinfecting wipes were
used to wipe down all surfaces. All materials that were used were disinfected with bleach and
wastewater from the experiment and sterilized with a 10% bleach solution before transmitting it
statistical significance of the results on the null hypothesis that the means of the data sets (E. coli
concentrations at the outflow with and without the T. versicolor) are the same and the alternative
hypothesis that they are different. If p<0.05 then the null hypothesis is rejected in favor of the
33
alternative, while if p>0.05, the null hypothesis is accepted (Helsel et al., 2020). These results
were calculated in Matlab using the anova1() function. In addition, the slope of the linear
regression of outflow E. coli concentrations through each experiment was tested for significance
using ANOVA in Excel. This was to test if E. coli concentrations decreased during each
4 RESULTS
Significantly high E. Coli levels were found in all sample sites, with samples collected on
nine dates. On average, 6.4 sites of the nine sampled were over the EPA limit for swimming of
235 cfu/100mL on any one sampling date. The McDaniel, CSO-2, and the Ripplewater sites
seem to have chronic contamination problems due to their consistently high E. coli
concentrations (Figure 12; Table 7). The highest concentrations were seen across all sites on
3/5/2020, where it had rained 1.52 in over 24 hours before sampling and 3.07 inches over 72
hours. This clearly indicates SSO spills and CSOs were likely prevalent during this large rain
event. Atlanta receives approximately 50 inches of rain per year, so this event represents 6% of
annual rain in three days. Interestingly, on this date, CSO-2, below the Custer Avenue CSO, was
the only site below the EPA limit likely due to primary treatment. This impact of stormflow on
E. coli contamination is supported by the samples from 10/17/19, which was after 0.52 inches of
rain over the prior 72 hours. On this date, all sites but CSO-1 were above the limit. CSO-1 is the
only site that routinely fell below the EPA limits. Even at baseflow, when 72-hour antecedent
34
precipitation was 0 in, any sites were above the standards but there was wide variability in the
Figure 12 E. coli concentrations in the Upper South River (Note: Because the Tift Site
was below the detection limit, it is not included in this figure.)
35
Table 7 E. coli and Total Coliform data for each sample site.
36
37
coli present in the Ripplewater creek sediment after sterilization of the sediment. As shown in
Figure 13 and 14, temporal variance occurred throughout each experiment (WOEC-1, WOEC-2,
and WOEC-3), but there were no statistically significant temporal trends. During this
Figure 13 E. coli concentrations every hour for the experiment with bleached sediment
and E. coli-free inflow. Error bars indicate the standard deviation of three outflow samples taken
at each timestep.
Figure 14 E. coli concentrations every hour for the experiment with bleached sediment
and E. coli-free inflow on a Log10 scale.
38
coli as well as observed natural changes in the E. coli concentrations due to metabolic processes
in the sediment alone, despite sediment bleaching. Figures 15 and 16 displays the results of the
second set of experiments wherein inputs of DI water spiked with E. coli (MPNs ranging from
(307.6 to 866.4) were pumped into the stream table system after which hourly samples were
obtained from the stream table output. Temporal variance was also observed throughout each
experiment in this subset. However, despite temporal variance, E. coli concentrations nominally
decreased compared to input concentrations by the end of each experiment. Variations through
time in E. coli concentrations here may be due in part by human error and/or IDEXX error.
Possible human error could have occurred during the determination of the titer concentration, in
handling the E. coli during transport and storage, and/or during the performance of the E. coli
dilutions.
Figure 15 E. coli concentrations every hour during the experiment with E. coli-spiked
input water but no mycelium. Triplicate samples were collected of the initial inflow
concentrations, which is shown at time 0 for each experiment.
39
Figure 16 E. coli concentrations every hour during the experiment with E. coli-spiked
input water but no mycelium on a Log10 scale. Triplicate samples were collected of the initial
inflow concentrations, which is shown at time 0 for each experiment.
In the final series of experiments (WTT-1,2,3), the Turkey Tail (T. versicolor) mycelium
was deployed in one cross section across the stream table (Figures 17, 18). Although overall the
output samples resulted in lower E. coli concentrations than the input, there was not a
statistically significant linear decline in concentration during any experiments. Calculating the
overall decrease in E. coli concentration from input to the end of the experiment shows no
difference in retention with the presence of the mycelium (Table 8, p=0.65). Although E. coli
removal was observed throughout various experiments overall, the removal of E. coli cannot be
contributed to the T. versicolor fungal spawn. However due to budget and time constraints, the
experiment was not performed more than 6 times total, thus limiting the statistical strengths of
these tests.
40
Figure 17 With Turkey Tail (Trametes versicolor) mycelium. Triplicates were collected
of the input concentrations, shown at time 0, with the standard deviation shown in the error bars.
Figure 18 With Turkey Tail (Trametes versicolor) mycelium on a Log10 scale. Triplicates
were collected of the input concentrations, shown at time 0.
*ANOVA analysis does not indicate a difference between average retention with mycelium and average
retention without mycelium. P=0.6
41
5.1 Discussion
The first objective of this study was to explore the effectiveness of mycofiltration in
decreasing E. coli concentrations during a short span of time (5 hours). Previous research
demonstrated E. coli removal success varying from 99.25% to 99.74% from Pleurotus ostreatus
(oyster mushroom) mycelium deployment for 48 to 96 hour durations (Pini and Geddes, 2020);
however, that research occurred on a shaker table where mycelium and contaminants could
interact continuously. In contrast, for actual field applications and to understand real-world
implications, hydrologic flow must be considered. Data produced from this research and
accounting for hyporheic flow paths, suggests that 4.5% more E. coli was removed with the T.
While these results are discouraging, they do not negate the potential for mycofiltration
efforts in longer term projects but merely suggest the limitations of mycofiltration for rapid
the efficacy of mycoremediation in field and lab applications (Kapahi and Sachdeva, 2017;
Kulshreshtha et al., 2014; Pini and Geddes, 2020; Stamets, 2005; Singh, 2006) and specifically
the use of T. versicolor as a good fit for mycoremediation (Álamo et al., 2018; Beltrán-Flores et
al., 2020; Cotter, 2014; Gebreyohannes et al., 2019; Hleba et al., 2014; Mir-Tutusaus et al.,
2014). Furthermore, this study was limited by the use of only one species of mycelium, only one
row of mycelium installation, and limited trials due to budget and time concerns. Additionally,
due to MPN statistical calculation methodology, the IDEXX Colilert-18 presents a potentially
The next objective of this study was to investigate effects of hydrology, specifically
discharge rate, on mycofiltration effectiveness and determine the significance of contact time
between E. coli contaminated water and the mycofilter. Research regarding contact time is
limited but thus far, overall data suggests that mycofiltration efficacy increases with an increase
in contact time. For example, E. coli removal increased after each subsequent week to 98% after
a total of three weeks immersed in a lab based pond setting (Martinez, 2016); however,
additional research has indicated a lower rate of reduction after 96 h immersed in a shaker table
with the highest rates at 48 h (Pini and Geddes, 2020). Lastly, increased discharge rate (likely
due to decreased contact time) has been shown to reduce mycofiltration efficacy (Stamets et al.,
2013). For example, research which did not account for hyporheic flow (but instead forced water
through the mycofilter) found a 20% reduction at 8.3 mL/s flow rate and a 14% reduction of E.
coli at the 36.7 mL/s rate with the use of Storpharia spp. mycofilter (Stamets et al., 2013). This
experiment follows that trend, showing a 28.8% reduction of E. coli at 5.2mL/s, although we
cannot differentiate the removal from natural sediment metabolism compared to the removal
from mycofiltration.
In a hypothetical field environment of a small order urban Piedmont stream, water could
be passing through the mycofilters at around 23 L/s discharge (average daily baseflow discharge
at USGS gage 02336030, North Fork of Peachtree, from July 1, 2019 to April 1, 2020) and after
high precipitation events the discharge rate, particularly in urban areas, could increase to 1773
L/s (highest mean daily discharge at that same gage for the same period). These considerations
are imperative to investigate in the laboratory before deployment in the field, and remain in
contrast to previous laboratory research which does not account for discharge (Pini and Geddes,
2020). While E. coli concentrations did decrease throughout the experiment when interacting
43
with T. versicolor mycelium at an average discharge rate of 5.2 +/- 0.28 mL/s, the results of this
study do not show statistically significant decreases that can be attributed to the mycofilter at
Differences in the response seen in these lab experiments to other published work highlight
multiple issues to be considered and addressed in future work. First, this experiment allowed for
hyporheic flow paths to form around the mycelium structure, a hydrologic flow path that is well-
known but has not been considered by other experiments. These hyporheic flow paths could
allow for water to move around the mycelium structure, depending on how they system is
installed, and decrease the interactions between contaminant and mycelium, especially
considering highly permeable systems. While hyporheic flow is well known for removing
zones, and increased residence times (Passeport et al.,2013), without the presences of mycelium
in the hyporheic zone, there is no benefit for E. coli remediation. Consideration of how to
address this issue will greatly improve the potential impact of future restoration approaches. This
includes considerations such as the potential effects of increasing the burlap barrier width or
including multiple burlap barriers along the stream table as well as the potential use of different
species of fungal spawn in future research. Secondly, mycelium deployment duration also plays
a pivotal role in E. coli reduction (Cotter, 2014). Highest rates of E. coli reduction have been
shown within a 48-hour period, but significant reduction rates continue up to 96 hours after
deployment (Pini and Geddes, 2020. This research stands in contrast to previous research
because the time frame of each experiment was significantly shorter (5 hours total). This
research has demonstrated that although E. coli reduction does begin within shorter time frames,
mycelium efficacy may not be significant for episodic bacterial contamination. While contact
44
time has been explored in past research, variation in E. coli concentrations remains largely
unexamined; however, E. coli input concentrations may also affect the efficacy of mycofiltration.
Of the six experiments during this research, E. coli inputs ranged in average from 472.95 to
873.3 MPN/100mL, other research utilized 800 cfu/100mL (Stamets et al., 2013). Additionally,
this research’s field data shows that E. coli concentrations in the Upper South River are
significantly higher and often exceed 1000 MPN/100mL (with a maximum concentration of
120,980 MPN/100mL observed) which may affect future field applications. Research utilizing
extremely high E. coli concentrations has yet to be explored, but may provide insight into future
mycofiltration efficacy.
5.2 Conclusion
of E. coli in flowing waters during short periods of time laboratory-scaled environment. The
findings of this study are that the T. versicolor mycofilter reduced concentrations of E. coli with
temporal variance throughout the experiments; however, results do not indicate any more
removal of E. coli from the water column compared to flow without the mycelium. These
streams may be limited by decreased contact time between contaminant and mycelium or
hyporheic flow paths that bypass the mycelium installation. According to this research, more
versicolor mycelium as well as to determine contact time. However, it must be noted that
mycoremediation is a burgeoning remediation method and has proven effective for heavy metal,
chemical, and bacterial removal from soils (Kapahi and Sachdeva, 2017; Kulshreshtha et al.,
2014; Singh, 2006). Additionally, it shows promise as a viable method for remediation of water
45
reservoirs, waste water treatment plants, and small scale surface water remediation installations
(Cotter, 2014; Martinez, 2016; Molla and Fakhru’l-Razi, 2012; Pini and Geddes, 2020; Singh,
2006). The usefulness of this technique once refined may be helpful in mitigating high bacterial
concentrations in small order urban streams resulting from increased precipitation events due to
climate change and continued coverage of impervious surfaces. This is important in light of the
lack of policy change and implementation to protect small order streams from consistent
degradation and limit human health exposure to high bacterial loads (Walsh and Ward, 2019).
46
REFERENCES
https://www.epa.gov/npdes/sanitary-sewer-overflows-ssos
United States Environmental Protection Agency. DeKalb County Clean Water Act Settlement.
2017. https://www.epa.gov/enforcement/dekalb-county-clean-water-act-settlement.
United States Geological Survey (USGS). USGS Water Resources Links for: 03070103 -
Upper Ocmulgee. https://water.usgs.gov/lookup/getwatershed?03070103/www/cgi-bin/
lookup/getwatershed (accessed February 29, 2020).
Velásquez, L.; Dussan, J. Biosorption and bioaccumulation of heavy metals on dead and living
biomass of Bacillus sphaericus. Journal of Hazardous Materials, 2009 167(1):713-716.
Walsh, Christopher J.; Roy, Allison H.; Feminella, Jack W.; Cottingham, Peter D.; Groffman,
Peter M.; Morgan II, Raymond P. The urban stream syndrome: current knowledge and
the search for a cure. Journal of the North American Benthological Society, 2005,
24, 706-723. doi: http://dx.doi.org/10.1899/04-028.1
Walsh, R. & Ward, A. Redefining Clean Water Regulations Reduces Protections for Wetlands
and Jurisdictional Uncertainty. Water, 2019. https://doi.org/10.3389/frwa.2019.00001
Retrieved from https://www.frontiersin.org/articles/10.3389/frwa.2019.00001/full