Pointer SA-A (Auto) Series Autoclave

Pointer series are pressure control autoclaves, have two


versions; the “Auto” Pointer version (SA-A), which is fully
automated once a session is started.

Reliable Sterilization Partner


Pointer SA-A (Auto) Series
Features
Autoclave
Pointer SA-A (Auto) Series
n Independent steam generator
n Wide range of usage
n Low water indication (Optional)
n Stainless steel chamber jacket, door support and steam generator
n Double wall chamber design
n Pre-heating program
n Cylindrical chamber volume: 100, 143, 196, 350 (L)

Reliable Sterilization Partner


Pointer SA-A (Auto) Series
Pointer SA-A (Auto) Series External View
Autoclave C

Pointer-SA-A (Cylindrical chamber) 1. Pressure Gauge of Chamber


3 4
1 2. Solenoid Valve Between Chamber & Jacket
2 5
A Temp. of Chamber B Door Handle 6 3. Safety Valve
4. Pressure Gauge of Jacket
5. Exhaust Solenoid Valve of Jacket
6. Emergency Valve

C D Exhaust Solenoid Valve of Chamber D


A Manual Water Fill Inlet

Add Water Valve

Control Panel

Boilwater Exhaust Valve

Reliable Sterilization Partner


Pointer SA-A (Auto) Series
Pointer SA-A (Auto) Series Control Panel
Autoclave
Heating Lamp Sterilization Lamp

Water Level Lamp Dry Lamp

Power Lamp Complete Lamp

Over Heat Lamp

Sterilization Timer Dry Timer

Start Switch

Reliable Sterilization Partner


Pointer SA-A (Auto) Series
Certifications
Autoclave
Sturdy is manufactured in compliance with the following directives and standards:

n 93/42/EEC
n Class IIB (European Directive for Medical Devices)
n 2014/68/EU (Pressure Equipment Directive)
n EN 285 (Large Steam Sterilizers),
n EN 13060 (Small Steam Sterilizers)
n EN 61010-1/-2-040 (Safety Requirements for Electrical Equipment for Measurement
n Control And Laboratory Use – Part 1 and Part 2)
n EN 61326-1 (Electrical Equipment for Measurement
n Control And Laboratory Use – EMC Requirements – Part 1: General Requirements)
n ISO 13485 (Quality Management/Certification)

Reliable Sterilization Partner


Pointer SA-A (Auto) Series
Pointer SA-A (Auto) Series Specifications
Autoclave
SPEC/Model NO. SA-400A SA-450A SA-500A SA-600A
Chamber Capacity (L) 100 143 196 350
Chamber Size
400 x 800 450 x 900 500 x 1000 610 x 1200
Diam x Depth (mm)
Overall Dimensions
630 x 1520 x 1070 670 x 1650 x 1250 670 x 1650 x 1290 800 x 1700 x 1475
W x H x D (mm)
Voltage (V) 230 / 380 (Mono / Tri phase)
Heater (KW) 7 9 12
Water Fill * Piped
Chamber Type Cylindrical
Pressure Option (bar) 0.9-2.1
Selectable Sterilization Timer 0-60 min.
Selectable Dry Timer 0-60 min.
Digital Printer N/A
6-Point Temp Sensor Recorder N/A
1-Point Temp Sensor Recorder N/A
Liquid O
* "Manual"- Water must be added manually. Manual water fill with optional piping.

Reliable Sterilization Partner


Pointer SA-A (Auto) Series
Pointer SA-A (Auto) Series Specifications
Autoclave
SPEC/Model NO. SA-400A SA-450A SA-500A SA-600A
Temperature Indicator Gauge
Pressure Indicator *2 Gauge
Progress Indicator (bar or lights) S
Power Indicator S
Pressure Auto Lock O
Reset N/A
Standby *3 N/A
Program Selector N/A
Pre-Vacuum N/A
Post Dry Vacuum O
Water Pump O
Note: "S" - Standard configuration. "O" - Optional configuration.
*2 "Gauge" - Includes both Jacket and Chamber pressure gauges.
*3 "Standby" - Allows the Big Autoclave to maintain jacket temperatures betweeen sterilization sessions.

Other notes:
- Standard Chamber / Jacket / Door / Housing are made of Stainless Steel#304. #316 Stainless steel optionally avaiable for Chamber / Jacket / Door.
- Heater material is Stainless Steel #316.
- Standard Accessories: Tray*1, Glass Viewer Tube * 2
- Optional Accessories: Trolley / Plate Set / Basket
- Sturdy also offers customized sizes up to 2000 L.

Reliable Sterilization Partner


Pointer SA-A (Auto) Series
Comparison Table - Floor Stand Series Feature Comparison

Model NO.
Autoclave
HP SAT SAP Pointer-Auto Pointer-Manual
Specification
Mechanical Pressure Control
Control System Digital Temp. PLC Control Mechanical Pressure Control
Optional: (T) for Digital Temp. Control
Program for selection
Yes N/A
Wrapped/Unwrapped/Liquid
Air Removal Vacuum Pump Gravity
Pre-Vacuum Function Yes N/A
Post(Dry)-Vacuum Function Yes Optional (V) N/A
Dry function Yes (Auto) Yes (Manual)
Printer & USB storage Yes N/A
1-point temp. recorder N/A Yes Optional (X) N/A
6-point temp. recorder N/A Optional (Y) N/A
Double Door Optional (D) N/A
Fill water system* Manual
Auto Manual
(Water pressure 2 bar required) Optional (B) for auto
Chamber/Jacket
Gauge / LCD Display Gauge
Pressure display
Stand-by Switch Yes N/A
Emergency/Reset Switch Yes N/A
Add-Water Pump Optional (W) Optional (BW) N/A
Water level Protection Yes Optional (L)
Pressure door auto-lock Yes Optional (K)

Option Codes (e.g. Optional (V)) listed in the table above are only reference codes used by other documentation.

Reliable Sterilization Partner


Pointer SA-A (Auto) Series
Option Codes
Autoclave
Option Codes (e.g. Optional (V)) listed in the table above are only reference codes used by other documentation.
B: AUTO-ADD WATER PLUMBING (WATER PRESSURE OF 2 BARS REQUIRED)
D: DOUBLE DOOR DEVICE
K: PRESSURE DOOR AUTO-LOCK DEVICE
L: WATER LEVEL CONTROLLER (LOW WATER INDICATOR)
T: DIGITAL DISPLAYED TEMP. CONTROLLER
V: DRY VACUUM PUMP
W: ADD WATER PUMP
X: 1-POINT TEMP. RECORDER
Y: 6-POINT TEMP. RECORDER