Installation and User Manual: Gyrofocus
Installation and User Manual: Gyrofocus
Installation and User Manual: Gyrofocus
Installation and
User Manual
1. Technical Data 2
2. PRE-Installation 3
3. INSTALLATION 5
4. Operation 11
5. TestING 12
Oblica
200 Argyle St
Fitzroy VIC 3065
03 9416 0400
1. Technical Data
Weight and dimensions:
Firebox diameter 1250mm
Firebox weight 92Kg
Flue diameter 219mm
Flue weight 16Kg/meter
Standard bracket weight 20Kg
External flue kit Triple skin 200/250/300mm
FLUE
ø219 mm
FIREBOX
ø1250 mm
500 mm
Caution:
Using components or parts other than those provided by the manufacturer or modifying the specification of components
may result in inferior or unsafe operation. If such action is necessary, consult the manufacturer in the first instance.
Warning:
• The appliance and flue-system must be installed in accordance with AS/NZS 2918 and the
relevant building code or codes.
• Any modification of the appliance that has not been approved in writing by the testing authority
will be in breach of the approval granted for compliance with AS/NZS 4013.
• Once the flue has been installed and approved by a professional installer, the flue must not be
modified in any way.
520
100
700
520
100
700
Non Combustible
Non Combustible
Combustible
Combustible
100 100 FIXED 480
FIXE
FULLY ROTATINGFULLY
700ROTATING 700
Non Combustible Combustible Combustible
520
100
700
Non Combustible
Combustible
100 700mm minimum
FULLY ROTATING 700 clearance is required if the rotation
FIXED 480
2.2 Clearance from glass
of the GyroFocus is locked at 120˚ or 90˚ away from the
500mm minimum
Glassclearance is required from normal
Glass wall. Locking the GyroFocus so that the opening is fixed
(frameless or aluminium frame)
(frameless or aluminium frame)
non-combustible glass. is an option available on purchase.
(frameless or aluminium
500
700Glass
Glass
500 500
Non Combustible
Glass
Combustible
Combustible
500
CHINAMAN HAT
(Anti-Down-Draft device)
RUBBER FLASHING
Insulative pad
250
CEILING FLANGE
150
12
SUSPENSION BRACKET
40
CONNECTOR
The top of the flue must be 400mm higher than the highest point of the roof. Alternatively, there must be a
minimum distance of 8 meters from any higher section of roof.
–> 40 cm >
–8m
> 40
– cm
–> 40 cm
–> 40 cm >
–8m
> 40
– cm
–> 40 cm
>
–8m
–> 120
Flat roof installation (less than 5˚ cm
pitch)
–> 120 cm >
– 120 cm
The top of the flue must be 1200mm above the roofline. Alternatively, there must be a minimum distance of
8 meters from any higher section of roof.
>
–8m
–> 120 cm
Grab Screw
2. Engage the firebox with the bolt bearings as per the diagram below.
Washers
ø21/40
ep. 3mm
Bearing holder
ø13/27
M12 nuts
Combustible 300mm
Combustible 300mm Combustible 300mm
Combustible 300mm Insulative board (20mm) floor (eg. timber)
floor (eg. timber) Insulative board (20mm) floor (eg. timber)
floor (eg. timber) + non combustible finish
+ non combustible finish
Joist
Joist
Combustible
Combustible 300mm
300mm Insulativeboard
board(20mm)
(20mm)
floor (eg.
(eg. timber)
timber) Insulative
floor ++ non
noncombustible
combustiblefinish
finish
Joist
Joist
Combustible 300mm
floor (eg. timber) Non combustible finish
(eg.tiles)
Concrete
TOP VIEW
300mm
FIREBOX
Floor protector /
non combustible finish
IMPORTANT:
• Misuse may lead to unhealthy and environmentally harmful emissions and will void any warranty or guarantee.
• The maximum load capacity for the GyroFocus is 20kg of wood.
• Burning only seasoned hardwood helps to protect the environment and lower emissions.
For details of a wood supplier in your area please call our office on 03 9416 0400 or email [email protected].
Warning:
• Do not use flammable liquids or aerosols to start or rekindle the fire.
• Do not use flammable liquids or aerosols in the vicinity of the fireplace when operating.
• Do not store fuel within prescribed installation clearance distances.
• The use of some types of preservative-treated woods as a fuel can be hazardous.