Artykuły naukowe
Przeglądaj według
Najnowsze pozycje
-
Stiffness and pre-stretching estimation from indentation test of hyperelastic membrane
(Elsevier, 2024)Obtaining precise data on the mechanical properties of soft materials, often in the form of thin, pre-tensioned membranes, is crucial, especially when conventional testing methods have limited applicability. The article ... -
Optical Bubble Microflow Meter for Continuous Measurements in a Closed System
(MDPI, 2024)This paper describes the design, operation and test results of a simple microprocessor-based device for measuring slow liquid flows. The device uses a module of 30 digital optical sensors to track the movement of a single ... -
Effect of Low-Temperature Oxygen Plasma Treatment of Titanium Alloy Surface on Tannic Acid Coating Deposition
(MDPI, 2024)In this study, the effect of low-temperature oxygen plasma treatment with various powers of a titanium alloy surface on the structural and morphological properties of a substrate and the deposition of a tannic acid coating ... -
Towards the First Generation of Biomimetic Fixation for Resurfacing Arthroplasty Endoprostheses
(MDPI, 2024)This paper presents advances in designs of resurfacing arthroplasty endoprostheses that occurred through their historical generations. The critical characteristics of contemporary generation hip resurfacing arthroplasty ... -
Bone Density Micro-CT Assessment during Embedding of the Innovative Multi-Spiked Connecting Scaffold in Periarticular Bone to Elaborate a Validated Numerical Model for Designing Biomimetic Fixation of Resurfacing Endoprostheses
(MDPI, 2021)Our team has been working for some time on designing a new kind of biomimetic fixation of resurfacing endoprostheses, in which the innovative multi-spiked connecting scaffold (MSC-Scaffold) that mimics the natural interface ... -
Subchondral Bone Relative Area and Density in Human Osteoarthritic Femoral Heads Assessed with Micro-CT before and after Mechanical Embedding of the Innovative Multi-Spiked Connecting Scaffold for Resurfacing THA Endoprostheses: A Pilot Study
(MDPI, 2021)The multi-spiked connecting scaffold (MSC-Scaffold) prototype is the essential innovation in the fixation of components of resurfacing total hip arthroplasty (THRA) endoprostheses in the subchondral trabecular bone. We ... -
Native Osseous CaP Biomineral Coating on a Biomimetic Multi-Spiked Connecting Scaffold Prototype for Cementless Resurfacing Arthroplasty Achieved by Combined Electrochemical Deposition
(MDPI, 2019)The multi-spiked connecting scaffold (MSC-Scaffold) prototype with spikes mimicking the interdigitations of articular subchondral bone is an essential innovation in surgically initiated fixation of resurfacing arthroplasty ... -
First Biomimetic Fixation for Resurfacing Arthroplasty: Investigation in Swine of a Prototype Partial Knee Endoprosthesis
(HIndawi, 2019)Resurfacing hip and knee endoprostheses are generally embedded in shallow, prepared areas in the bone and secured with cement. Massive cement penetration into periarticular bone, although it provides sufficient primary ... -
Structural-Geometric Functionalization of the Additively Manufactured Prototype of Biomimetic Multispiked Connecting Ti-Alloy Scaffold for Entirely Noncemented Resurfacing Arthroplasty Endoprostheses
(Hindawi, 2017)The multispiked connecting scaffold (MSC-Scaffold) prototype, inspired by the biological system of anchorage of the articular cartilage in the periarticular trabecular bone by means of subchondral bone interdigitations, ... -
Biomimetic Multispiked Connecting Ti-Alloy Scaffold Prototype for Entirely-Cementless Resurfacing Arthroplasty Endoprostheses-Exemplary Results of Implantation of the Ca-P Surface-Modified Scaffold Prototypes in Animal Model and Osteoblast Culture Evaluation
(MDPI, 2016)We present here - designed, manufactured, and tested by our research team-the Ti-alloy prototype of the multispiked connecting scaffold (MSC-Scaffold) interfacing the components of resurfacing arthroplasty (RA) endoprostheses ... -
Preliminary Results of Implantation in Animal Model and Osteoblast Culture Evaluation of Prototypes of Biomimetic Multispiked Connecting Scaffold for Noncemented Stemless Resurfacing Hip Arthroplasty Endoprostheses
(2013)We present the new fixation method for RHA (resurfacing hip arthroplasty) endoprostheses by means of the biomimetic multispiked connecting scaffold (MSC-Scaffold). Such connecting scaffold can generate new type of RHA ... -
Computer Aided Stereometric Evaluation of Porostructuralosteoconductive Properties of Intra-Osseous Implant Porous Coatings
(Polish Academy of Sciences Committee on Metrology and Scientific Instrumentation, 2013)The proper interaction of bone tissue – the natural porous biomaterial – with a porous coated intra-osseous implant is conditioned, among others, by the implant porous coating poroaccessibility for bone tissue adaptive ... -
Traditional Versus Mechatronic Toys in Children with Autism Spectrum Disorders
(2017)Functional and developmental outcomes in children (both healthy and with developmental disorders) can be significantly improved thanks to use of appropriate toys. There is need for new generation of toys providing ... -
Structural-Geometric Functionalization of the Additively Manufactured Prototype of Biomimetic Multispiked Connecting Ti-Alloy Scaffold for Entirely Noncemented Resurfacing Arthroplasty Endoprostheses
(2017)The multispiked connecting scaffold (MSC-Scaffold) prototype, inspired by the biological system of anchorage of the articular cartilage in the periarticular trabecular bone by means of subchondral bone interdigitations, ... -
Simulation of Diffusion Flows in Two-Phase Multilayered Stochastically Nonhomogeneous Bodies with Non-Uniform Distribution of Inclusions
(2015)Admixture diffusion flows are investigated in two-phase randomly nonhomogeneous multilayered strips with non-uniform distributions of inclusions. Cases where the most probable disposition of layered inclusions is located ... -
Mathematical Modeling of Random Diffusion Flows in Two-Phase Multilayered Stochastically Nonhomogeneous Bodies
(2015)An approach for studying stochastical diffusion flows of admixture particles in bodies of multiphase randomly nonhomogeneous structures is proposed, according to which initial-boundary value problems of diffusion are ... -
Construction of the solution of the thermal-convective drying problem for porous solids in drying plants
(2015)In this paper the approximate solutions of the one-dimensional linear mathematical model of porous bodies drying are obtained, which makes it possible to establish the temperature of the phase transition for arbitrary ... -
Timing belts in glass processing systems
(2013)Paper present main problems connected with exploitation of timing belts in fast growing production and processing systems. Mechatronics systems in glass production are the fastest developed field of application of ... -
Motion Analysis of Timing Belt Used in Control Systems
(2013)The paper presents the results of measurements and analyzes gear timing belts, used in control systems. Many of the design features of timing belt determines its usefulness in such systems. Knowledge of technical parameters ... -
Modification of Joints in Polymer Timing Belts
(2015)Teeth deformation measurements in the connection area indicate that each method of welded joint improvement, decreases deformation and thus improves power transfer capacity of joined belts. In the selected study it means ...