Abstract
Pulsed laser damage density measurements obtained with diverse facilities are difficult to compare, due to the interplay of numerous parameters, such as beam area and pulse geometry, which, in operational large beam conditions, are very different from laboratory measurements. This discrepancy could have a significant impact; if so, one could not even pretend that laser damage density control is a real measurement process. In this paper, this concern is addressed. Tests with large beams of centimeter size on a high-power laser facility have beam performed according to a parametric study and are compared to small beam laboratory tests. It is shown that laser damage densities obtained with large and small beams are equal, within calculated error bars.
© 2011 Optical Society of America
Full Article | PDF ArticleMore Like This
Matthieu Veinhard, Odile Bonville, Stéphane Bouillet, Roger Courchinoux, Romain Parreault, Jean-Yves Natoli, and Laurent Lamaignère
Appl. Opt. 59(31) 9643-9651 (2020)
Laurent Lamaignère, Kévin Gaudfrin, Thierry Donval, Jeanyves Natoli, Jean-Michel Sajer, Denis Penninckx, Roger Courchinoux, and Romain Diaz
Opt. Express 26(9) 11744-11755 (2018)
Bertrand Bertussi, Philippe Cormont, Stéphanie Palmier, Philippe Legros, and Jean-Luc Rullier
Opt. Express 17(14) 11469-11479 (2009)