Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Ranitzsch, Philipp [VerfasserIn]   i
 Kempf, Sebastian [VerfasserIn]   i
 Pabinger, Andreas [VerfasserIn]   i
 Pies, Christian [VerfasserIn]   i
 Porst, J. -P. [VerfasserIn]   i
 Schäfer, Stefan [VerfasserIn]   i
 Fleischmann, Andreas [VerfasserIn]   i
 Gastaldo, Loredana [VerfasserIn]   i
 Enss, Christian [VerfasserIn]   i
 Jang, Y. S. [VerfasserIn]   i
 Kim, I. H. [VerfasserIn]   i
 Kim, M. S. [VerfasserIn]   i
 Kim, Y. H. [VerfasserIn]   i
 Lee, J. S. [VerfasserIn]   i
 Lee, K. B. [VerfasserIn]   i
 Lee, M. K. [VerfasserIn]   i
 Lee, S. J. [VerfasserIn]   i
 Yoon, W. S. [VerfasserIn]   i
 Yuryev, Y. N. [VerfasserIn]   i
Titel:Development of cryogenic alpha spectrometers using metallic magnetic calorimeters
Verf.angabe:P.C. Ranitzsch, S. Kempf, A. Pabinger, C. Pies, J.-P. Porst, S. Schäfer, A. Fleischmann, L. Gastaldo, C. Enss, Y.S. Jang, I.H. Kim, M.S. Kim, Y.H. Kim, J.S. Lee, K.B. Lee, M.K. Lee, S.J. Lee, W.S. Yoon, Y.N. Yuryev
Jahr:2011
Umfang:3 S.
Fussnoten:Available online 23 November 2010 ; Gesehen am 12.09.2022
Titel Quelle:Enthalten in: Nuclear instruments & methods in physics research / A
Ort Quelle:Amsterdam : North-Holland Publ. Co., 1984
Jahr Quelle:2011
Band/Heft Quelle:652(2011), 1, Seite 299-301
ISSN Quelle:0168-9002
Abstract:Cryogenic particle detectors have recently been adopted in radiation detection and measurement because of their high energy resolution. Many of these detectors have demonstrated energy resolutions better than the theoretical limit of semiconductor detectors. We report the development of a micro-fabricated magnetic calorimeter coupled to a large-area particle absorber. It is based on a planar, 1mm2 large paramagnetic temperature sensor made of sputtered Au:Er, which covers a superconducting meander-shaped pickup coil coupled to a low-noise dc-SQUID to monitor the magnetization of the sensor. A piece of gold foil of 2.5×2.5×0.07mm3 was glued to the Au:Er film to serve as an absorber for incident alpha particles. The detector performance was investigated with an 241Am source. The signal size comparison for alpha and gamma peaks with a large difference in energy demonstrated that the detector had good linear behavior. An energy resolution of 2.83±0.05keV in FWHM was obtained for 5.5MeV alpha particles.
DOI:doi:10.1016/j.nima.2010.11.066
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag: https://doi.org/10.1016/j.nima.2010.11.066
 Volltext: https://www.sciencedirect.com/science/article/pii/S016890021002557X
 DOI: https://doi.org/10.1016/j.nima.2010.11.066
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Alpha spectrometry
 Cryogenic detector
 Metallic magnetic calorimeter
K10plus-PPN:1816416185
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68963313   QR-Code

zum Seitenanfang