High harmonic generation
High-harmonic generation (HHG) is a non-linear process during which a target (gas, plasma, solid or liquid sample) is illuminated by an intense laser pulse. Under such conditions, the sample will emit the high order harmonics of the generation beam (above the fifth harmonic). Due to the coherent nature of the process, high-harmonics generation is a prerequisite of attosecond physics.
Perturbative harmonic generation
[edit]Perturbative harmonic generation is a process whereby laser light of frequency ω and photon energy ħω can be used to generate new frequencies of light. The newly generated frequencies are integer multiples nω of the original light's frequency. This process was first discovered in 1961 by Franken et al.,[1] using a ruby laser, with crystalline quartz as the nonlinear medium.
Harmonic generation in dielectric solids is well understood and extensively used in modern laser physics (see second-harmonic generation). In 1967 New et al. observed the first third harmonic generation in a gas.[2] In monatomic gases it is only possible to produce odd numbered harmonics for reasons of symmetry. Harmonic generation in the perturbative (weak field) regime is characterised by rapidly decreasing efficiency with increasing harmonic order.[3] This behaviour can be understood by considering an atom absorbing n photons then emitting a single high energy photon. The probability of absorbing n photons decreases as n increases, explaining the rapid decrease in the initial harmonic intensities.
Development
[edit]The first high harmonic generation was observed in 1977 in interaction of intense CO2 laser pulses with plasma generated from solid targets.[4] HHG in gases, far more widespread in application today, was first observed by McPherson and colleagues in 1987,[5] and later by Ferray et al. in 1988,[6] with surprising results: the high harmonics were found to decrease in intensity at low orders, as expected, but then were observed to form a plateau, with the intensity of the harmonics remaining approximately constant over many orders.[7] Plateau harmonics spanning hundreds of eV have been measured which extend into the soft X-ray regime.[8] This plateau ends abruptly at a position called the high harmonic cut-off.
Properties
[edit]High harmonics have a number of interesting properties. They are a tunable table-top source of XUV/soft X-rays, synchronised with the driving laser and produced with the same repetition rate. The harmonic cut-off varies linearly with increasing laser intensity up until the saturation intensity Isat where harmonic generation stops.[9] The saturation intensity can be increased by changing the atomic species to lighter noble gases but these have a lower conversion efficiency so there is a balance to be found depending on the photon energies required.
High harmonic generation strongly depends on the driving laser field and as a result the harmonics have similar temporal and spatial coherence properties.[10] High harmonics are often generated with pulse durations shorter than that of the driving laser.[11] This is due to the nonlinearity of the generation process, phase matching and ionization. Often harmonics are only produced in a very small temporal window when the phase matching condition is met. Depletion of the generating media due to ionization also means that harmonic generation is mainly confined to the leading edge of the driving pulse.[12]
High harmonics are emitted co-linearly with the driving laser and can have a very tight angular confinement, sometimes with less divergence than that of the fundamental field and near Gaussian beam profiles.[13]
Semi-classical approach
[edit]The maximum photon energy producible with high harmonic generation is given by the cut-off of the harmonic plateau. This can be calculated classically by examining the maximum energy the ionized electron can gain in the electric field of the laser. The cut-off energy is given by:[14]
where Up is the ponderomotive energy from the laser field and Ip is the ionization potential.
This cut-off energy is derived from a semi-classical calculation, often called the three-step model. The electron is initially treated quantum mechanically as it tunnel ionizes from the parent atom, but its subsequent dynamics are treated classically. The electron is assumed to be born into the vacuum with zero initial velocity, and to be subsequently accelerated by the laser beam's electric field.
Half an optical cycle after ionization, the electron will reverse direction as the electric field changes sign, and will accelerate back towards the parent nucleus. Upon return to the parent nucleus it can then emit bremsstrahlung-like radiation during a recombination process with the atom as it returns to its ground state. This description has become known as the recollisional model of high harmonic generation.[15]
Since the frequency of the emitted radiation depends on both the kinetic energy and on the ionization potential, the different frequencies are emitted at different recombination times (i.e. the emitted pulse is chirped). Furthermore, for every frequency, there are two corresponding recombination times. We refer to these two trajectories as the short trajectory (which are emitted first), and the long trajectory.
In the semiclassical picture, HHG will only occur if the driving laser field is linearly polarised. Ellipticity on the laser beam causes the returning electron to miss the parent nucleus. Quantum mechanically, the overlap of the returning electron wavepacket with the nuclear wavepacket is reduced. This has been observed experimentally, where the intensity of harmonics decreases rapidly with increasing ellipticity.[16] Another effect which limits the intensity of the driving laser is the Lorentz force. At intensities above 1016 W·cm−2 the magnetic component of the laser pulse, which is ignored in weak field optics, can become strong enough to deflect the returning electron. This will cause it to "miss" the parent nucleus and hence prevent HHG.
Phase matching
[edit]As in every nonlinear process, phase matching plays an important role in high harmonic generation in the gas phase. In free-focusing geometry, the four causes of wavevector mismatch are: neutral dispersion, plasma dispersion, Gouy phase, and dipole phase.[17][18]
The neutral dispersion is caused by the atoms while the plasma dispersion is due to the ions, and the two have opposite signs. The Gouy phase is due to wavefront phase jump close to the focus, and varies along it. Finally the dipole phase arises from the atomic response in the HHG process.[19] When using a gas jet geometry, the optimal conditions for generating high harmonics emitted from short trajectories are obtained when the generating gas is located after the focus, while generation of high harmonics from long trajectory can be obtained off-axis when the generating gas is located before the focus.[20]
Furthermore, the implementation of loose focusing geometry for the driving field enables a higher number of emitters and photons to contribute to the generation process and thus, enhance the harmonic yield.[21] When using a gas jet geometry, focusing the laser into the Mach disk can increase the efficiency of harmonic generation.[22]
More generally, in the X-ray spectral region, materials have a refractive index that is very close to 1. To balance the phase mismatch, , we need to find such parameters in the high dimensional space that will effectively make the combined refractive index at the driving laser wavelength nearly 1.
In order to achieve intensity levels that can distort an atom's binding potential, it is necessary to focus the driving laser beam. This introduces dispersion terms affecting the phase mismatch, depending on the specific geometry (such as plane wave propagation, free focusing, hollow core waveguide, etc.). Additionally, during the high harmonic generation process, electrons are accelerated, and some of them return to their parent ion, resulting in X-ray bursts. However, the majority of these electrons do not return and instead contribute to dispersion for the co-propagating waves. The returning electrons carry phase due to processes like ionization, recombination, and propagation. Furthermore, the ionized atoms can influence the refractive index of the medium, providing another source of dispersion.
The phase mismatch (> 0 phase velocity of the laser is faster than that of the X-rays) can be represented as:
where is the neutral atoms contribution, is the contribution from ions (when neutrals are ionized, this term can be still sufficiently large in the UV[23]), is the plasma contribution, is the free focusing geometry, plane-wave of waveguiding geometry, is the phase accumulated by the electron during the time it spends away from the atom, etc. Each term has a specific sign which allows balancing the mismatch at a particular time and frequency.
The contribution from the electrons scales quadratically with the wavelength: , while the contribution from atoms scales inversely with wavelength: . Thus at long IR wavelengths, the term is quite large per electron, while the term is quite small and close to one. To phase-match the process of HHG, very high pressures and low ionization levels are required, thus giving a large number of emitters.[24] In the opposite UV spectral range, the term is large because of the closely located UV resonances, and in addition, the term is small. To phase-match the process, low pressures are needed. Moreover, in the UV, very high ionization levels can be tolerated (much larger than 100%). This gives HHG photon energy scalability with the intensity of the driving UV laser.[23] Plain-wave geometry or loose focusing geometry allows highly collinear phase matching and maximum flux extraction at the driving wavelengths where the term is small. The generation of High-order harmonics in waveguide allows propagation with characteristics close to those of plane wave propagation.[25] Such geometries benefit, especially X-ray spectra generated by IR beams, where long interaction volumes are needed for optimal power extraction. In such geometries, spectra extending to 1.6 keV, have been generated.[24] For UV-VIS driven high harmonics, the waveguide term is small, and the phase-matching picture resembles the plane-wave geometry. In such geometries, narrow bandwidth harmonics extending to the carbon edge (300 eV) have been generated.[23]
See also
[edit]- Attosecond physics
- Nonlinear optics
- Photoionization
- Resonant high harmonic generation from laser ablated plasma plumes
References
[edit]- ^ P. A. Franken, A. E. Hill, C. W. Peters, and G. Weinreich, Phys. Rev. Lett. 7, 118 (1961).
- ^ New, G. H. C.; Ward, J. F. (1967). "Optical Third-Harmonic Generation in Gases". Phys. Rev. Lett. 19 (10): 556–559. Bibcode:1967PhRvL..19..556N. doi:10.1103/physrevlett.19.556.
- ^ J. Wildenauer, Journal of Applied Physics 62, 41 (1987).
- ^ Burnett, N. H.; et al. (1977). "Harmonic generation in CO2 laser target interaction". Appl. Phys. Lett. 31 (3): 172–174. Bibcode:1977ApPhL..31..172B. doi:10.1063/1.89628.
- ^ McPherson, A.; et al. (1987). "Studies of multiphoton production of vacuum-ultraviolet radiation in the rare gases". JOSA B. 4 (4): 595. Bibcode:1987JOSAB...4..595M. doi:10.1364/JOSAB.4.000595.
- ^ Ferray, M.; et al. (1988). "Multiple-harmonic conversion of 1064 nm radiation in rare gases". Journal of Physics B: Atomic, Molecular and Optical Physics. 21 (3): L31. Bibcode:1988JPhB...21L..31F. doi:10.1088/0953-4075/21/3/001. S2CID 250827054.
- ^ Li, X. F.; L'Huillier, A.; Ferray, M.; Lompre, L. A.; Mainfray, G. (1989). "Multiple-harmonic generation in rare gases at high laser intensity". Physical Review A. 39 (11): 5751–5761. Bibcode:1989PhRvA..39.5751L. doi:10.1103/physreva.39.5751. PMID 9901157.
- ^ Seres, J.; et al. (2005). "Laser technology: Source of coherent kiloelectronvolt X-rays". Nature. 433 (7026): 596. Bibcode:2005Natur.433..596S. doi:10.1038/433596a. PMID 15703738. S2CID 4425428.
- ^ Brabec, T.; Krausz, F. (2000). "Intense few-cycle laser fields: Frontiers of nonlinear optics". Reviews of Modern Physics. 72 (2): 545–591. Bibcode:2000RvMP...72..545B. doi:10.1103/revmodphys.72.545.
- ^ L'Huillier, A.; Schafer, K. J.; Kulander, K. C. (1991). "Theoretical aspects of intense field harmonic generation". Journal of Physics B: Atomic, Molecular and Optical Physics. 24 (15): 3315–3341. Bibcode:1991JPhB...24.3315L. doi:10.1088/0953-4075/24/15/004. S2CID 250751106.
- ^ Streaking of 43-attosecond soft-X-ray pulses generated by a passively CEP-stable mid-infrared, https://doi.org/10.1364/OE.25.027506
- ^ Schafer, K. J.; Kulander, K. C. (1997). "High Harmonic Generation from Ultrafast Pump Lasers". Physical Review Letters. 78 (4): 638–641. Bibcode:1997PhRvL..78..638S. doi:10.1103/physrevlett.78.638.
- ^ Tisch, J. W. G.; et al. (1994). "Angularly resolved high-order harmonic generation in helium". Physical Review A. 49 (1): R28–R31. Bibcode:1994PhRvA..49...28T. doi:10.1103/physreva.49.r28. PMID 9910285.
- ^ Krause, Jeffrey L.; Schafer, Kenneth J.; Kulander, Kenneth C. (1992). "High-order harmonic generation from atoms and ions in the high intensity regime". Physical Review Letters. 68 (24): 3535–3538. Bibcode:1992PhRvL..68.3535K. doi:10.1103/PhysRevLett.68.3535. PMID 10045729.
- ^ Corkum, P. B. (1993). "Plasma perspective on strong field multiphoton ionization". Physical Review Letters. 71 (13): 1994–1997. Bibcode:1993PhRvL..71.1994C. doi:10.1103/physrevlett.71.1994. PMID 10054556. S2CID 29947935.
- ^ Dietrich, P.; Burnett, N. H.; Ivanov, M.; Corkum, P. B. (1994). "High-harmonic generation and correlated two-electron multiphoton ionization with elliptically polarized light". Physical Review A. 50 (5): R3585–R3588. Bibcode:1994PhRvA..50.3585D. doi:10.1103/physreva.50.r3585. PMID 9911439.
- ^ Altucci, C.; Starczewski, T.; Mevel, E.; Wahlström, C.-G.; Carré, B.; L'Huillier, A. (1996). "Influence of atomic density in high-order harmonic generation". J. Opt. Soc. Am. B. 13 (1): 148–156. Bibcode:1996JOSAB..13..148A. doi:10.1364/JOSAB.13.000148.
- ^ Pascal, Salieres; L'Huillier, Anne; Lewenstein, Maciej (1995). "Coherence control of high-order harmonics" (PDF). Physical Review Letters. 74 (19): 3776–3779. Bibcode:1995PhRvL..74.3776S. doi:10.1103/physrevlett.74.3776. PMID 10058294. S2CID 35091499.
- ^ Lewenstein, Maciej; Salieres, Pascal; L'huillier, Anne (1995). "Phase of the atomic polarization in high-order harmonic generation". Physical Review A. 52 (6): 4747–4754. Bibcode:1995PhRvA..52.4747L. doi:10.1103/physreva.52.4747. PMID 9912816.
- ^ Balcou, Philippe; Salieres, Pascal; L'Huillier, Anne; Lewenstein, Maciej (1997). "Generalized phase-matching conditions for high harmonics: The role of field-gradient forces". Physical Review A. 55 (4): 3204–3210. Bibcode:1997PhRvA..55.3204B. doi:10.1103/PhysRevA.55.3204.
- ^ Takahashi, E.; Nabekawa, Y.; Midorikawa, K. (2002). "Generation of 10-uj coherent extreme-ultraviolet light by use of high-order harmonics". Optics Letters. 27 (21): 1920–1922. Bibcode:2002OptL...27.1920T. doi:10.1364/OL.27.001920. PMID 18033402.
- ^ Grant-Jacob, James; Mills, Ben; Butcher, Tom; Chapman, Richard; Brocklesby, William; Frey, Jeremy (2011). "Gas jet structure influence on high harmonic generation" (PDF). Optics Express. 19 (10): 9801–9806. Bibcode:2011OExpr..19.9801G. doi:10.1364/OE.19.009801. PMID 21643236.
- ^ a b c Popmintchev, D.; Hernández-García, C.; Dollar, F.; Mancuso, C. A.; Peng, P.-C.; Barwick, B.; Gorman, T. T.; Alonso-Mori, R.; Ališauskas, S.; Andriukaitis, G.; Baltuška, A.; Bostedt, C.; Chen, M.-C.; Dakovski, G. L.; Durfee, C. G.; Eckert, S.; Fan, T.-M.; Ferguson, W. R.; Frischkorn, C. G.; et al. (2015). "Ultraviolet surprise: Efficient soft x-ray high-harmonic generation in multiply ionized plasmas". Science. 350 (6265): 1225–1231. Bibcode:2015Sci...350.1225P. doi:10.1126/science.aac9755. hdl:10366/147088. PMID 26785483. S2CID 2342988.
- ^ a b Popmintchev, T.; Chen, M.-C.; Popmintchev, D.; Arpin, P.; Brown, S.; Alisauskas, S.; Andriukaitis, G.; Balciunas, T.; Mücke, O. D.; Pugzlys, A.; Baltuska, A.; Shim, B.; Schrauth, S. E.; Gaeta, A.; Hernández-García, C.; Plaja, L.; Becker, A.; Jaron-Becker, A.; Murnane, M. M.; et al. (2012). "Bright coherent ultrahigh harmonics in the keV x-ray regime from mid-infrared femtosecond lasers". Science. 336 (6086): 1287–1291. arXiv:2403.19535. Bibcode:2012Sci...336.1287P. doi:10.1126/science.1218497. hdl:10366/147089. PMID 22679093. S2CID 24628513.
- ^ Rundquist, A.; Durfee, C. G.; Chang, Z.; Herne, C.; Backus, S.; Murnane, M. M.; Kapteyn, H. C. (1998). "Phase-matched generation of coherent soft X-rays". Science. 280 (5368): 1412–1415. arXiv:2403.19636. Bibcode:1998Sci...280.1412R. doi:10.1126/science.280.5368.1412. PMID 9603725.