{{Short description|Electrical switch that opens and closes a circuit when a small amount of the liquid metal mercury connects metal electrodes to close the circuit}}
[[File:Mercury Switch without housing.jpg|thumb|A ''Single-Pole, Single-Throw'' (''SPST'') mercury switch on millimetre graph paper]]
[[File:Mercury Switch without housing.jpg|thumb|A ''Single-Pole, Single-Throw'' (''SPST'') mercury switch on millimetre graph paper]]
[[File:Mercury switch.jpg|thumb|Another mercury switch design]]
[[File:Mercury switch.jpg|thumb|Another mercury switch design]]


A '''mercury switch''' is an electrical [[switch]] that opens and closes a [[electrical circuit|circuit]] when a small amount of the liquid metal [[mercury (element)|mercury]] connects metal electrodes to close the circuit. There are several different basic designs (tilt, displacement, radial, etc.) but they all share the common design strength of non-eroding switch contacts.
A '''mercury switch''' is an electrical [[switch]] that opens and closes a [[electrical circuit|circuit]] when a small amount of the liquid metal [[mercury (element)|mercury]] connects metal electrodes to close the circuit. There are several different basic designs (tilt, displacement, radial, etc.) but they all share the common design strength of non-eroding switch contacts.


The most common is the ''mercury tilt switch''. It is in one state (open or closed) when tilted one direction with respect to horizontal, and the other state when tilted the other direction. This is what older style thermostats used to turn a heater or air conditioner on or off.
The most common is the ''mercury tilt switch''. It is in one state (open or closed) when tilted one direction with respect to horizontal, and the other state when tilted the other direction. This is what older style thermostats used to turn a heater or air conditioner on or off.


The ''mercury displacement switch'' uses a 'plunger' that dips into a pool of mercury, raising the level in the container to contact at least one electrode. This design is used in relays in industrial applications that need to switch high current loads frequently. These relays use electromagnetic coils to pull steel sleeves inside [[hermetically sealed]] containers.
The ''mercury displacement switch'' uses a 'plunger' that dips into a pool of mercury, raising the level in the container to contact at least one electrode. This design is used in relays in industrial applications that need to switch high current loads frequently. These relays use electromagnetic coils to pull steel sleeves inside [[hermetically sealed]] containers.


==Description==
==Description==
Mercury switches have one or more sets of [[electrical contact]]s in a sealed [[glass]] envelope that contains a small quantity of mercury. The envelope may also contain hydrogen at pressure, an [[inert gas]], or a vacuum. Gravity constantly pulls the drop of mercury to the lowest point in the envelope. When the switch is tilted in the appropriate direction, the mercury touches a set of contacts, thus completing an electrical circuit. Tilting the switch in the opposite direction moves the mercury away from that set of contacts, breaking that circuit.<ref>{{cite book |first=Jacob |last=Fraden |title=Handbook of Modern Sensors - Physics, Designs and Applications (3rd Edition)'' |publisher=Springer - Verlag |year=2004 |pages= 256-257 }}</ref> The switch may contain multiple sets of contacts, closing different sets at different angles, allowing, for example, single-pole, double-throw (''[[Changeover switch|SPDT]]'') operation.
Mercury switches have one or more sets of [[electrical contact]]s in a sealed [[glass]] envelope that contains a small quantity of mercury. The envelope may also contain hydrogen at pressure, an [[inert gas]], or a vacuum. Gravity constantly pulls the drop of mercury to the lowest point in the envelope. When the switch is tilted in the appropriate direction, the mercury touches a set of contacts, thus completing an electrical circuit. Tilting the switch in the opposite direction moves the mercury away from that set of contacts, breaking that circuit.<ref>{{cite book |first=Jacob |last=Fraden |title=Handbook of Modern Sensors - Physics, Designs and Applications (3rd Edition)'' |publisher=Springer - Verlag |year=2004 |pages= 256–257 }}</ref> The switch may contain multiple sets of contacts, closing different sets at different angles, allowing, for example, single-pole, double-throw (''[[Changeover switch|SPDT]]'') operation.


==Advantages==
==Advantages==
Line 19: Line 20:
* Sensitivity of the drop to gravity provides a unique sensing function, and lends itself to simple, low-force mechanisms for manual or automatic operation.
* Sensitivity of the drop to gravity provides a unique sensing function, and lends itself to simple, low-force mechanisms for manual or automatic operation.
* The switches are quiet, as no contacts abruptly snap together.
* The switches are quiet, as no contacts abruptly snap together.
* The mass of the moving mercury drop provides an [[Bistability|over center]] effect to avoid [[Switch#Contact_bounce|chattering]] as the switch tilts.
* The mass of the moving mercury drop provides an [[Bistability|over center]] effect to avoid [[Switch#Contact bounce|chattering]] as the switch tilts.
* The envelope can include contacts for two or more circuits.
* The envelope can include contacts for two or more circuits.


Line 28: Line 29:
* The mercury drop forms a common electrode, so circuits are not isolated from each other in a multi-pole switch.
* The mercury drop forms a common electrode, so circuits are not isolated from each other in a multi-pole switch.
* Their sensitivity to gravity may make them unsuitable in portable or mobile devices that can change orientation or vibrate.
* Their sensitivity to gravity may make them unsuitable in portable or mobile devices that can change orientation or vibrate.
* Mercury compounds are [[Mercury_(element)#Toxicity_and_safety|highly toxic]] and accumulate in any [[food chain]], so safety codes exclude mercury in many new designs.
* Mercury compounds are [[Mercury (element)#Toxicity and safety|highly toxic]] and accumulate in any [[food chain]], so safety codes exclude mercury in many new designs.


==Uses==
==Uses==
Line 39: Line 40:
===Fall alarms===
===Fall alarms===
Work performed in [[confined space]] (such as a welder inside a tank) raises special safety concerns. Tilt switches sound an alarm if a worker falls over.
Work performed in [[confined space]] (such as a welder inside a tank) raises special safety concerns. Tilt switches sound an alarm if a worker falls over.

===Aircraft attitude indicators/artificial horizons===
===Aircraft attitude indicators/artificial horizons===
Electrically driven attitude indicators typically use mercury switches to keep the gyro axis vertical. When the gyro is off vertical, mercury switches trigger torque motors that move the gyro position back to the correct position. (Air driven attitude indicators use a different operating principle.)
Electrically driven attitude indicators typically use mercury switches to keep the gyro axis vertical. When the gyro is off vertical, mercury switches trigger torque motors that move the gyro position back to the correct position. (Air driven attitude indicators use a different operating principle.)
Line 50: Line 51:


===Pressure switches===
===Pressure switches===
Some [[pressure switch]]es use a [[Bourdon tube]] and a mercury switch. The small force generated by the tube reliably operates the switch.
Some [[pressure switch]]es use a [[Bourdon tube]] and a mercury switch. The small force generated by the tube reliably operates the switch.


===Vending===
===Vending===
Line 78: Line 79:


==External links==
==External links==
{{Commonscat|Mercury switches}}
{{Commons category|Mercury switches}}
* [http://www.societyofrobots.com/sensors_mercury_switch.shtml How to Adapt a Mercury Switch for Robot Control]
* [http://www.societyofrobots.com/sensors_mercury_switch.shtml How to Adapt a Mercury Switch for Robot Control]


{{Switches}}
{{Switches}}

{{Authority control}}


{{DEFAULTSORT:Mercury Switch}}
{{DEFAULTSORT:Mercury Switch}}

Revision as of 01:36, 17 January 2021

A Single-Pole, Single-Throw (SPST) mercury switch on millimetre graph paper
Another mercury switch design

A mercury switch is an electrical switch that opens and closes a circuit when a small amount of the liquid metal mercury connects metal electrodes to close the circuit. There are several different basic designs (tilt, displacement, radial, etc.) but they all share the common design strength of non-eroding switch contacts.

The most common is the mercury tilt switch. It is in one state (open or closed) when tilted one direction with respect to horizontal, and the other state when tilted the other direction. This is what older style thermostats used to turn a heater or air conditioner on or off.

The mercury displacement switch uses a 'plunger' that dips into a pool of mercury, raising the level in the container to contact at least one electrode. This design is used in relays in industrial applications that need to switch high current loads frequently. These relays use electromagnetic coils to pull steel sleeves inside hermetically sealed containers.

Description

Mercury switches have one or more sets of electrical contacts in a sealed glass envelope that contains a small quantity of mercury. The envelope may also contain hydrogen at pressure, an inert gas, or a vacuum. Gravity constantly pulls the drop of mercury to the lowest point in the envelope. When the switch is tilted in the appropriate direction, the mercury touches a set of contacts, thus completing an electrical circuit. Tilting the switch in the opposite direction moves the mercury away from that set of contacts, breaking that circuit.[1] The switch may contain multiple sets of contacts, closing different sets at different angles, allowing, for example, single-pole, double-throw (SPDT) operation.

Advantages

Mercury switches offer several advantages over other switch types:

  • The contacts are enclosed, so oxidation of the contact points is impossible.
  • In hazardous locations, interrupting the circuit does not emit a spark that could ignite flammable gases.
  • Contacts stay clean, and even if an internal arc occurs, the contact surfaces renew on every operation, so they don't wear out.
  • Even a small drop of mercury has low resistance, so switches can carry useful amounts of current in a small size.[2]
  • Sensitivity of the drop to gravity provides a unique sensing function, and lends itself to simple, low-force mechanisms for manual or automatic operation.
  • The switches are quiet, as no contacts abruptly snap together.
  • The mass of the moving mercury drop provides an over center effect to avoid chattering as the switch tilts.
  • The envelope can include contacts for two or more circuits.

Disadvantages

Mercury switches have several disadvantages:

  • Their relatively slow operating rate (due to the inertia of the mercury drop) makes them unsuitable for applications that require many operating cycles per second.[3]
  • Glass envelopes and wire electrodes may be fragile and require flexible leads to prevent damage to the envelope.
  • The mercury drop forms a common electrode, so circuits are not isolated from each other in a multi-pole switch.
  • Their sensitivity to gravity may make them unsuitable in portable or mobile devices that can change orientation or vibrate.
  • Mercury compounds are highly toxic and accumulate in any food chain, so safety codes exclude mercury in many new designs.

Uses

Roll sensing

Tilt switches provide a rollover or tip over warning for applications like construction equipment and lift vehicles that operate in rugged terrain. There are several non-mercury types, but few are implemented due to sensitivity to shock and vibration, causing false tripping. However, devices resistant to shock and vibration do exist.

Automotive uses

Automobile manufacturers once used mercury switches for lighting controls (for example, trunk lid lights), ride control, and anti-lock braking systems. Scrapped automobiles can leak mercury to the environment if these switches are not properly removed. Since 2003, new American-built cars no longer use mercury switches.[4][5]

Fall alarms

Work performed in confined space (such as a welder inside a tank) raises special safety concerns. Tilt switches sound an alarm if a worker falls over.

Aircraft attitude indicators/artificial horizons

Electrically driven attitude indicators typically use mercury switches to keep the gyro axis vertical. When the gyro is off vertical, mercury switches trigger torque motors that move the gyro position back to the correct position. (Air driven attitude indicators use a different operating principle.)

Thermostats

Mercury switches were once common in bimetal thermostats. The weight of the movable mercury drop provided some hysteresis by a degree of over-center action. The bimetal spring had to move further to overcome the weight of the mercury, tending to hold it in the open or closed position. The mercury also provided positive on-off switching, and could withstand millions of cycles without contact degradation.

Doorbells

Some old doorbells, for example, the Soviet ZM-1U4, use mercury switches as current interrupters.

Pressure switches

Some pressure switches use a Bourdon tube and a mercury switch. The small force generated by the tube reliably operates the switch.

Vending

Mercury switches are still used in electro-mechanical systems where physical orientation of actuators or rotors is a factor. They are also commonly used in vending machines for tilt alarms that detect when someone tries to rock or tilt the machine to make it vend a product.

Bombs

A tilt switch can trigger a bomb.[6][7] Mercury tilt switches can be found in some bomb and landmine fuzes, typically in the form of anti-handling devices, for example, a variant of the VS-50 mine.

Toxicity

Since mercury is a poisonous heavy metal, devices containing mercury switches must be treated as hazardous waste for disposal. Because it is now RoHS restricted, most modern applications have eliminated it. A metal ball and contact wires can directly replace it, but may require additional circuitry to eliminate switch bounce. Low-precision thermostats use a bimetal strip and a switch contact. Precision thermostats use a thermistor or silicon temperature sensor. Low-cost accelerometers replace the mercury tilt switch in precision applications.

In the United States, the Environmental Protection Agency (EPA) regulates the disposition and release of mercury.[8] Individual states and localities may enact further regulations on the use or disposition of mercury.

See also

References

  1. ^ Fraden, Jacob (2004). Handbook of Modern Sensors - Physics, Designs and Applications (3rd Edition). Springer - Verlag. pp. 256–257.
  2. ^ Martin J. Heathcote, The J & P transformer book: a practical technology of the power transformer Newnes, 2007 ISBN 0-7506-8164-0 p.285
  3. ^ David W. Pessen, Industrial automation: circuit design and components,Wiley-IEEE, 1989 ISBN 0-471-60071-7, page 44
  4. ^ United States, Mercury study report to Congress, DIANE Publishing, 1997 ISBN 1-4289-0372-0, page 2-11
  5. ^ Organisation for Economic Co-operation and Development, Instrument mixes for environmental policy OECD Publishing, 2007,ISBN 92-64-01780-1, pg.145
  6. ^ Vallely, Paul (22 February 2002). "The Airey Neave Files". The Independent. London. Retrieved 12 May 2010.
  7. ^ "1979: Car bomb kills Airey Neave". BBC News. 30 March 1979. Retrieved 26 March 2010.
  8. ^ "Mercury: Laws and regulations". United States Environmental Protection Agency. 2008-04-16. Retrieved 2008-05-30.