Effects of SF$_{6}$ on the avalanche mode operation of a real-sized double-gap resistive plate chamber for the Compact Muon Solenoid experiment / Ahn Sung Hwan ; Bahk, S Y ; Hong, B ; Hong, S J ; Ito, M ; Kim, B I ; Kim, J H ; Kim, Y J ; Kim, Y U ; Koo, D G et al.
We present the design and the test, results for a real-sized prototype resistive plate chamber by using cosmic-ray muons for the forward region of the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC). In particular, we investigate the effects of adding SF/sub 6/ to the gas mixture for the avalanche mode operation of a resistive plate chamber. [...]
2005 - Published in : J. Korean Phys. Soc.: 46 (2005) , no. 5, pp. 1090-1095
2.
Aspects of operational conditions of a double gap prototype RPC for the CMS/LHC experiment / Ahn, S H ; Amirikas, R ; Bahk, S Y ; Baik, K M ; Gapienko, V A ; Hong, B ; Hong, S J ; Kim, J Y ; Kim, Y J ; Kim, Y U et al.
This paper presents the results from cosmic ray tests performed in the framework of R&D; effort on the forward Resistive Plate Chamber (RPC) for CMS. A double gap RPC of dimensions 50*50 cm/sup 2/ with 2 mm gas gaps was tested. [...]
2001 - Published in : Nucl. Instrum. Methods Phys. Res., A 465 (2001) 447-54
3.
Study on the operational conditions of a double-gap resistive plate chamber for the CMS / Ahn, S H ; Amirikas, R ; Bahk, S Y ; Baik, K M ; Gapienko, V A ; Hong, B ; Hong, S J ; Kim, J Y ; Kim, Y J ; Kim, Y U et al.
We present the results from cosmic ray tests on the forward Resistive Plate Chamber (RPC) for the CMS. Double-gap prototype RPC were built and tested in the Korea Detector Laboratory (KODEL). [...]
2000 - Published in : Nucl. Instrum. Methods Phys. Res., A 456 (2000) 29-34
In : 5th Workshop on Resistive Plate Chambers and Related Detectors, Bari, Italy, 28 - 29 Oct 1999
4.
Performance and simulation of a double-gap resistive plate chamber in the avalanche mode / Ahn Sung Hwan ; Bahk, S Y ; Hong Byung Sik ; Hong Seong Jong ; Ito, M ; Kang, T I ; Kim, B I ; Kim, J H ; Kim, Y J ; Kim, Y U et al.
We present a detailed analysis of the time and the charge signals of a prototype double-gap resistive plate chamber for the endcap region of the Compact Muon Solenoid (CMS) detector at the Large Hadron Collider (LHC). The chamber was built with relatively low-resistivity bakelite. [...]
2004 - Published in : J. Korean Phys. Soc.: 45 (2004) , no. 6, pp. 1490-1499
5.
Operation of a RPC with low resistivity bakelite for the endcap region of CMS in a high-rate environment / Ahn, S H ; Choi, E J ; Hong, B ; Hong, S J ; Kang, D H ; Kim, T J ; Lee, K S ; Park, S ; Park, W J ; Ryu, M S et al.
We present the beam-test results for a real-size prototype resistive plate chamber (RPC) for the endcap region of the Compact Muon Solenoid (CMS) experiment at CERN Large Hadron Collider (LHC). The chamber built with relatively low resistivity bakelite was tested at the Gamma Irradiation Facility (GIF) at CERN under a high photon-flux environment with an effective cluster rate up to about 1.2 kHz/cm/sup 2/. [...]
2002 - Published in : J. Korean Phys. Soc.: 41 (2002) , no. 5, pp. 667-73
6.
Ageing test of RPC for the Muon Trigger System for the ALICE experiment / Arnaldi, Roberta ; Baldit, A ; Barret, V ; Bastid, N ; Blanchard, G ; Chiavassa, E ; Cortese, P ; Crochet, P ; De Marco, N ; Dellacasa, G et al.
The trigger detectors for the Muon Forward Spectrometer of the ALICE experiment will be single gap RPCs with low-resistivity bakelite electrodes. The detector will take data for different colliding systems resulting in a wide range of working conditions and requirements, especially concerning position resolution and lifetime. [...]
2004
In : 51st Nuclear Science Symposium and Medical Imaging Conference, Rome, Italy, 16 - 22 Oct 2004, pp.2072-2076 (v.4)
7.
Beam test result of a large real-size RPC for the CMS/LHC experiment / Ahn, S H ; Amirikas, R ; Bahk, S Y ; Baik, K M ; Gapienko, V A ; Hong, B ; Hong, S J ; Kim, J Y ; Kim, K H ; Kim, Y J et al.
In this report, first beam test results for a real size RE2-2 prototype RPC for the forward region of the CERN CMS are presented. The beam test for the prototype RPC was performed at the Gamma Irradiation Facility (GIF) in CERN with a particle rate ranging up to ~700 Hz/cm/sup 2/. [...]
2000 - Published in : Nucl. Instrum. Methods Phys. Res., A 456 (2000) 23-8
In : 5th Workshop on Resistive Plate Chambers and Related Detectors, Bari, Italy, 28 - 29 Oct 1999
8.
Test beam results on resistive plate chamber prototype at gamma irradiation facility in CERN / Chung, C H ; Kim, D H ; Kim, M J ; Kim, M S ; Kong, D J ; Park, K H ; Shim, H S ; Yun, C W
We report recent results on performances of 2 mm double-gap RPC operated with the CERN SPS X5 120 GeV muon beams under high rate /sup 137/Cs irradiation. We obtained the efficiency and time resolution and other related physical parameters. [...]
1999 - Published in : Nucl. Instrum. Methods Phys. Res., A 432 (1999) 14-23
9.
Characteristics of a double gap resistive plate chamber for the endcap region of CMS/LHC : Data vs simulation in avalanche mode / Ahn, S H ; Bahk, S Y ; Hong, B ; Hong, S J ; Kang, D H ; Kang, T I ; Kim, K H ; Kim, T J ; Kim, Y J ; Kim, Y U et al.
We present the detailed analysis of the time and charge signals of a prototype double gap resistive plate chamber for the endcap region of the compact muon solenoid detector at CERN LHC. We demonstrate that the operating high-voltage plateau can be extended at least up to 400 V with the present design. [...]
2004 - Published in : Nucl. Instrum. Methods Phys. Res., A 533 (2004) 32-36
10.
R&D of a real-size mosaic MRPC within the framework of the CMS muon upgrade / CMS RPC Collaboration
Based on previous experience and attempt, a real-size mosaic Multi-gap Resistive Plate Chamber (MRPC) has been developed within the framework of the CMS muon upgrade efforts. The chamber is a 5-gap with plates made each of 6 pieces of low resistive glass. [...]
2019 - 10 p. - Published in : JINST 14 (2019) C10042
In : RPC 2018 - THE XIV WORKSHOP ON RESISTIVE PLATE CHAMBERS AND RELATED DETECTORS, Puerto Vallarta, Mexico, 19 - 23 Feb 2018, pp.C10042

Nenašli ste čo ste hľadali? Skúste Vašu otázku na iných serveroch:
recid:915984 v Amazon
recid:915984 v CERN EDMS
recid:915984 v CERN Intranet
recid:915984 v CiteSeer
recid:915984 v Google Books
recid:915984 v Google Scholar
recid:915984 v Google Web
recid:915984 v IEC
recid:915984 v IHS
recid:915984 v INSPIRE
recid:915984 v ISO
recid:915984 v KISS Books/Journals
recid:915984 v KISS Preprints
recid:915984 v NEBIS
recid:915984 v SLAC Library Catalog