CERN Accelerating science

CERN Document Server 2,049 Datensätze gefunden  1 - 10nächsteEnde  gehen zum Datensatz: Die Suche hat 3.46 Sekunden gedauert. 
1.
Investigation of Ge/P-Doped Silica Optical Fibers for Radiation Sensing / Kandemir, K (CERN) ; Tagkoudi, E (CERN) ; Francesca, D Di (CERN) ; Ricci, D (CERN)
The distributed optical fiber radiation sensor (DOFRS) developed by CERN is a key technology for the spatially continuous and real-time monitoring of radiation dose in harsh environments. Silica-based optical fibers (OFs) doped or co-doped with phosphorous are used as sensing elements of the DOFRS systems. [...]
2024 - 6 p. - Published in : IEEE Trans. Nucl. Sci.

In : Conference on Radiation and its Effects on Components and Systems (RADECS 2023), Toulouse, France, 25 - 29 Sep 2023, pp.6
2.
Implementation of Optical-Fiber Postmortem Dose Measurements: A Proof of Concept / Francesca, Diego Di (CERN) ; Kandemir, Keziban (CERN) ; Vecchi, Gaetano Li (CERN) ; Alia, Rubén Garcia (CERN) ; Kadi, Yacine (CERN) ; Brugger, Markus (CERN)
We describe the implementation of a versatile system and the corresponding method to perform fast postmortem optical attenuation measurements on irradiated optical-fibers (OFs) for dosimetry purposes. The measurement is based on the radiation-induced attenuation (RIA) phenomenon. [...]
2019 - 6 p. - Published in : IEEE Trans. Nucl. Sci. 67 (2019) 140-145
3.
Distributed Optical Fiber Radiation Sensing in the Proton Synchrotron Booster at CERN / Di Francesca, D (CERN) ; Toccafondo, I (CERN) ; Li Vecchi, G (CERN ; Lab. Hubert Curien, St. Etienne) ; Calderini, S (CERN) ; Girard, S (Lab. Hubert Curien, St. Etienne) ; Alessi, A (Lab. Hubert Curien, St. Etienne) ; Ferraro, R (CERN) ; Danzeca, S (CERN) ; Kadi, Y (CERN) ; Brugger, M (CERN)
In this paper, we report on the development and first deployment of a distributed optical fiber radiation sensor (DOFRS) for the online monitoring of radiation levels in the high-energy accelerator facilities of CERN. The DOFRS is composed of two basic parts: a set of suitably chosen radiation sensitive optical fibers (OFs), to be installed in the machine tunnel, and an optical time domain reflectometer (OTDR), to be installed in a radiation-free area. [...]
2018 - 6 p. - Published in : IEEE Trans. Nucl. Sci. 65 (2018) 1639-1644
4.
Temperature Effect on the Radioluminescence of Differently Doped Silica-Based Optical Fibers / Kerboub, Nourdine (CERN ; CNES, Toulouse ; Lab. Hubert Curien, St. Etienne) ; Di Francesca, Diego (CERN) ; Morana, Adriana (Lab. Hubert Curien, St. Etienne) ; Hamzaoui, Hicham El (PhLAM, Villeneuve d'Ascq) ; Ouerdane, Youcef (Lab. Hubert Curien, St. Etienne) ; Bouwmans, Géraud (PhLAM, Villeneuve d'Ascq) ; Habert, Rémi (PhLAM, Villeneuve d'Ascq) ; Cassez, Andy (PhLAM, Villeneuve d'Ascq) ; Boukenter, Aziz (Lab. Hubert Curien, St. Etienne) ; Capoen, Bruno (PhLAM, Villeneuve d'Ascq) et al.
We evaluate the temperature effect on the X-ray radiation-induced luminescence (RIL) of differently doped silica fibers obtained via the sol-gel route. Previous investigations showed that these optical materials exhibit interesting dosimetry properties, such as very good detection capabilities and linear response over a large range of dose rate. [...]
2024 - 7 p. - Published in : IEEE Trans. Nucl. Sci. 71 (2024) 2280-2286
5.
Temperature Effect on the Radioluminescence of Cu-, Ce-, and CuCe-Doped Silica-Based Fiber Materials / Kerboub, Nourdine (CERN ; HCL, Lyon ; CNES, Toulouse) ; Di Francesca, Diego (CERN ; HCL, Lyon) ; Girard, Sylvain (HCL, Lyon) ; Morana, Adriana (Lyon, Ecole Centrale) ; El Hamzaoui, Hicham (Lille U.) ; Ouerdane, Youcef (HCL, Lyon) ; Bouwmans, Géraud (Lille U.) ; Habert, Rémi (Lille U.) ; Boukenter, Aziz (HCL, Lyon) ; Capoen, Bruno (Lille U.) et al.
We evaluate the temperature effect on the X-ray radiation-induced luminescence (RIL) of Cu- or Ce-single-doped and CuCe-codoped silica glass. Previous investigations showed that these optical materials exhibit interesting dosimetry properties, such as very good detection capabilities and linear response over a large range of dose rate. [...]
2021 - 6 p. - Published in : IEEE Trans. Nucl. Sci. 68 (2021) 1782-1787
6.
Radiation Environment in the Large Hadron Collider During the 2022 Restart and Related RHA Implications / Biłko, Kacper (CERN ; Lab. Hubert Curien, St. Etienne) ; García Alía, Rubén (CERN) ; Aguiar, Ygor (CERN) ; Danzeca, Salvatore (CERN) ; Di Francesca, Diego (CERN) ; Gilardoni, Simone (CERN) ; Girard, Sylvain (ICJ, Lyon ; IUF, Paris) ; Ricci, Daniel (CERN) ; Sebban, Marc (Lab. Hubert Curien, St. Etienne) ; Uznanski, Slawosz (CERN)
In this work, we present the radiation environment of the large hadron collider (LHC), focusing on the year 2022, the first after the Long Shutdown 2 (LS2) (2019–2021). We highlight the most prominent radiation-level changes with respect to the 2018 operation, commenting on the related Radiation Hardness Assurance implications. [...]
2024 - 11 p. - Published in : IEEE Trans. Nucl. Sci. 71 (2024) 607-617 Fulltext: PDF;
7.
CERN Super Proton Synchrotron Radiation Environment and Related Radiation Hardness Assurance Implications / Biłko, Kacper (CERN ; Lab. Hubert Curien, St. Etienne) ; García Alía, Rubén (CERN) ; Di Francesca, Diego (CERN) ; Aguiar, Ygor (CERN) ; Danzeca, Salvatore (CERN) ; Gilardoni, Simone (CERN) ; Girard, Sylvain (Lab. Hubert Curien, St. Etienne) ; Esposito, Luigi Salvatore (CERN) ; Fraser, Matthew Alexander (CERN) ; Mazzola, Giuseppe (CERN) et al.
The super proton synchrotron (SPS) is the second largest accelerator at CERN where protons are accelerated between 16 and 450 GeV/c. Beam losses, leading to the mixed-field radiation of up to MGy magnitude, pose a threat to the reliability of the electronic equipment and polymer materials located in the tunnel and its vicinity. [...]
2023 - 10 p. - Published in : IEEE Trans. Nucl. Sci.
Fulltext: PDF;
In : European Conference on Radiation and its Effects on Components and Systems, Venice, Italy, 3 - 7 Oct 2022, pp.1606-1615
8.
Radiation Monitoring With Radiosensitive Pure-Silica Core Ultralow Loss Optical Fiber / Weninger, Luca (Lab. Hubert Curien, St. Etienne) ; Morana, Adriana (Lab. Hubert Curien, St. Etienne) ; Campanella, Cosimo (Lab. Hubert Curien, St. Etienne) ; Vidalot, Jeoffray (Lab. Hubert Curien, St. Etienne) ; Marin, Emmanuel (Lab. Hubert Curien, St. Etienne) ; Ouerdane, Youcef (Lab. Hubert Curien, St. Etienne) ; Boukenter, Aziz (Lab. Hubert Curien, St. Etienne) ; Alía, Rubén García (CERN) ; Girard, Sylvain (Lab. Hubert Curien, St. Etienne ; IUF, Paris)
This article presents a new prospect for radiation detection exploiting the high radiation sensitivity of an ultralow-loss pure-silica core optical fiber (ULL-PSCF). This fiber exhibits very high transient X-ray radiation-induced attenuation (RIA) levels from UV to IR during irradiation, while its RIA quickly returns to a low permanent level after irradiation. [...]
2024 - 8 p. - Published in : IEEE Trans. Nucl. Sci.
Fulltext: PDF;
In : Conference on Radiation and its Effects on Components and Systems (RADECS 2023), Toulouse, France, 25 - 29 Sep 2023, pp.1813-1820
9.
Calibration in the Visible and Infrared Domains of Multimode Phosphosilicate Optical Fibers for Dosimetry Applications / Weninger, Luca (Lab. Hubert Curien, St. Etienne) ; Campanella, Cosimo (Lab. Hubert Curien, St. Etienne) ; Morana, Adriana (Lab. Hubert Curien, St. Etienne) ; Fricano, Fiammetta (Lab. Hubert Curien, St. Etienne) ; Marin, Emmanuel (Lab. Hubert Curien, St. Etienne) ; Ouerdane, Youcef (Lab. Hubert Curien, St. Etienne) ; Boukenter, Aziz (Lab. Hubert Curien, St. Etienne) ; García Alía, Rubén (CERN) ; Girard, Sylvain (Lab. Hubert Curien, St. Etienne)
We systematically explore the suitability of two radiation-sensitive multimode optical fibers (OFs) with either P or GeP-doped cores to serve as the sensing elements in point or distributed dosimeters. To this end, we measured the dependences of their spectral radiation-induced attenuation (RIA) in the visible and near-infrared (near-IR) domain (400–2100 nm) up to total ionizing dose (TID) of 5 kGy(SiO2) while varying the irradiation temperature from −80 °C to +80 °C and the dose rate between 1 mGy(SiO2)/s and 10 Gy(SiO2)/s. [...]
2023 - 9 p. - Published in : IEEE Trans. Nucl. Sci.

In : European Conference on Radiation and its Effects on Components and Systems, Venice, Italy, 3 - 7 Oct 2022, pp.1908-1916
10.
Dosimetry Mapping of Mixed-Field Radiation Environment Through Combined Distributed Optical Fiber Sensing and FLUKA Simulation / Di Francesca, Diego (CERN) ; Infantino, Angelo (CERN) ; Li Vecchi, Gaetano (CERN ; Jean Monnet U. ; Lab. Hubert Curien, St. Etienne) ; Girard, Sylvain (Jean Monnet U. ; Lab. Hubert Curien, St. Etienne) ; Alessi, Antonino (Jean Monnet U. ; Lab. Hubert Curien, St. Etienne) ; Kadi, Yacine (CERN) ; Brugger, Markus (CERN)
Distributed optical fiber (OF) radiation sensing is a technique recently adopted at CERN for the monitoring of radiation dose levels in the proton synchrotron (PS) booster and in the PS. In this paper, we present the progress made on our previous work by benchmarking the rich information contained in the spatially distributed OF dose measurement with the radiation levels simulated with the FLUKA Monte Carlo code. [...]
2019 - 7 p. - Published in : IEEE Trans. Nucl. Sci. 66 (2019) 299-305

Haben Sie nicht gefunden was Sie suchten? Versuchen Sie Ihre Suche auf anderen Servern:
recid:2919591 in Amazon
recid:2919591 in CERN EDMS
recid:2919591 in CERN Intranet
recid:2919591 in CiteSeer
recid:2919591 in Google Books
recid:2919591 in Google Scholar
recid:2919591 in Google Web
recid:2919591 in IEC
recid:2919591 in IHS
recid:2919591 in INSPIRE
recid:2919591 in ISO
recid:2919591 in KISS Books/Journals
recid:2919591 in KISS Preprints
recid:2919591 in NEBIS
recid:2919591 in SLAC Library Catalog