CERN Accelerating science

CERN Document Server Намерени са 2,043 записа  1 - 10следващкрай  отиване на запис: Търсенето отне 0.44 секунди. 
1.
Ageing test of RPC for the Muon Trigger System for the ALICE experiment / Arnaldi, Roberta ; Baldit, A ; Barret, V ; Bastid, N ; Blanchard, G ; Chiavassa, E ; Cortese, P ; Crochet, P ; De Marco, N ; Dellacasa, G et al.
The trigger detectors for the Muon Forward Spectrometer of the ALICE experiment will be single gap RPCs with low-resistivity bakelite electrodes. The detector will take data for different colliding systems resulting in a wide range of working conditions and requirements, especially concerning position resolution and lifetime. [...]
2004
In : 51st Nuclear Science Symposium and Medical Imaging Conference, Rome, Italy, 16 - 22 Oct 2004, pp.2072-2076 (v.4)
2.
The performance of RPCs with bakelite electrodes of resistivity under high radiation fluxes / Cwiok, M ; Dominik, Wojciech ; Górski, M ; Królikowski, J
Three medium-size Resistive Plate Chambers (RPCs) with bakelite electrodes having resistivity of 5*10/sup 8/, 5*10/sup 9/ and 3*10 /sup 10/ Omega cm were tested in the Gamma Irradiation Facility at CERN in 1997, 1998 and 1999. The 2 mm gap modules working in an Inverted Double Gap configuration filled with gas mixtures containing freon C/sub 2/H/sub 2/F/sub 4/ and operated in avalanche mode exhibit wide efficiency plateau, good time resolution and small time walk due to rate variation even at intensities as high as 1 kHz/cm/sup 2//gap of a continuous radiation flux. [...]
2000 - Published in : Nucl. Instrum. Methods Phys. Res., A 456 (2000) 87-90
In : 5th Workshop on Resistive Plate Chambers and Related Detectors, Bari, Italy, 28 - 29 Oct 1999
3.
Streamer free operation of a 2 mm gap resistive plate chamber with $C_{2}F_{5}H$ / Cerron-Zeballos, E ; Crotty, Ian ; Hatzifotiadou, D ; Lamas-Valverde, J ; Williams, M C S ; Zichichi, A
It is necessary to operate the resistive plate chamber (RPC) in avalanche mode to obtain high efficiency at elevated particle fluxes. We examine this mode of operation with a 2 mm gap RPC using gas mixtures containing C/sub 2/F/sub 4/H/sub 2/ and C/sub 2/F/sub 5/H. [...]
Geneva : CERN, 1999
In : 36th INFN Eloisatron Project Workshop : New Detectors "Ettore Majorana", Erice, Italy, 1 - 7 Nov 1997, pp.350-369
4.
Highly efficient resistive plate chambers for high rate environment / Cwiok, M ; Dominik, Wojciech ; Górski, M ; Królikowski, J
The full scale prototype of an inverted double gap RPC module for ME-1/1 station of the CMS detector was tested in the gamma irradiation facility at the CERN SPS muon beam. The chamber made of medium resistivity bakelite and filled with "green gas" mixture of C /sub 2/H/sub 2/F/sub 4//iso-butane/SF/sub 6/ has wide efficiency plateau and good timing properties when operated in avalanche mode under continuous irradiation with strong /sup 137/Cs source for rates up to about 5 kHz/cm/sup 2//gap. [...]
1999 - Published in : Nucl. Phys. B, Proc. Suppl. 78 (1999) 438-43
5.
Ageing tests on the low-resistivity RPC for the ALICE dimuon arm / Arnaldi, R ; Baldit, A ; Barret, V ; Bastid, N ; Blanchard, G ; Chiavassa, E ; Cortese, P ; Crochet, Philippe ; De Marco, N ; Dellacasa, G et al.
The trigger for the Dimuon Forward Spectrometer of the forthcoming ALICE experiment at CERN LHC will be provided by low-resistivity, single gap Resistive Plate Chambers working in streamer mode. Different ageing test were performed to measure and improve the life- time of the detector. [...]
2003 - Published in : Nucl. Instrum. Methods Phys. Res., A 508 (2003) 106-109
In : 6th International Workshop on Resistive Plate Chambers and Related Detectors, Coimbra, Portugal, 26 - 27 Nov 2001, pp.106-109
6.
Test beam results on resistive plate chamber prototype at gamma irradiation facility in CERN / Chung, C H ; Kim, D H ; Kim, M J ; Kim, M S ; Kong, D J ; Park, K H ; Shim, H S ; Yun, C W
We report recent results on performances of 2 mm double-gap RPC operated with the CERN SPS X5 120 GeV muon beams under high rate /sup 137/Cs irradiation. We obtained the efficiency and time resolution and other related physical parameters. [...]
1999 - Published in : Nucl. Instrum. Methods Phys. Res., A 432 (1999) 14-23
7.
The micro-gap resistive plate chamber / Cerron-Zeballos, E ; Hatzifotiadou, D ; Lamas-Valverde, J ; Platner, E D ; Roberts, J ; Williams, M C S ; Zichichi, A
Previously we have found that the freon C/sub 2/F/sub 5/H has very good properties when used in a resistive plate chamber (RPC) with a single gap of 2 mm. In this paper we report on the performance of a multigap RPC consisting of 4 gaps of 0.8 mm filled with a gas mixture containing this freon. [...]
Geneva : CERN, 1999
In : 36th INFN Eloisatron Project Workshop : New Detectors "Ettore Majorana", Erice, Italy, 1 - 7 Nov 1997, pp.370-391
8.
A facility for the measurement of electron transport parameters in a gas mixture / Golovatyuk, V M ; Gorini, E ; Grancagnolo, F ; Perrino, R ; Primavera, M
A facility for studying electron transport parameters in a given gas mixture is illustrated. A controlled ionization is induced by means of multiple-photon processes by focussing a short (~1 ns) pulsed nitrogen laser in the gas gap. [...]
2001 - Published in : Nucl. Instrum. Methods Phys. Res., A 461 (2001) 96-7
9.
A low resistivity RPC for the trigger of the ALICE di-muon arm / ALICE Collaboration
Resistive Plate Chambers (RPC) operated in streamer mode are expected to provide the trigger of the ALICE dimuon forward spectrometer. To match the requirements concerning the rate capability (about 100 Hz/cm2, including a large safety factor), several prototypes have been realized with low-resistivity Bakelite electrodes and a strongly quenching gas mixture. [...]
CERN-ALI-2001-053; CERN-ALICE-PUB-2001-53.- Geneva : CERN, 2001 - 6 p. - Published in : PoS hep2001 (2001) 267 Access to fulltext document: PDF; Published version from PoS: PDF;
In : International Europhysics Conference on High-Energy Physics, Budapest, Hungary, 12 - 18 Jul 2001, pp.267 - CERN library copies
10.
Performances of Resistive Plate chamber Operated in Avalanche Mode under 137Cs Irradiation / Abbrescia, Marcello (INFN, Bari, Italy) ; Colaleo, Anna (INFN, Bari, Italy) ; Gianini, Gabriele (INFN, Bari, Italy) ; Iaselli, Giuseppe (INFN, Bari, Italy) ; Maggi, Marcello (INFN, Bari, Italy) ; Marangelli, Bartolomeo (INFN, Bari, Italy) ; Natali, Sergio (INFN, Bari, Italy) ; Nuzzo, Salvatore (INFN, Bari, Italy) ; Ranieri, Antonio (INFN, Bari, Italy) ; Ratti, Sergio P (INFN, Bari, Italy) et al.
A 2 mm gas RPC with bakelite plates has been operated in avalanche mode under 137Cs source irradiation. We report on measurements of the efficiency in cosmic rays detection and of the charge developed in the gap, performed for different gas mixtures [...]
CMS-NOTE-1997-003.- Geneva : CERN, 1997 Fulltext: PDF PS.Z;

Не намерихте, каквото търсите? Опитайте търсене в други сървъри:
recid:913831 в Amazon
recid:913831 в CERN EDMS
recid:913831 в CERN Intranet
recid:913831 в CiteSeer
recid:913831 в Google Books
recid:913831 в Google Scholar
recid:913831 в Google Web
recid:913831 в IEC
recid:913831 в IHS
recid:913831 в INSPIRE
recid:913831 в ISO
recid:913831 в KISS Books/Journals
recid:913831 в KISS Preprints
recid:913831 в NEBIS
recid:913831 в SLAC Library Catalog