1.
|
Temperature Effect on the Radioluminescence of Differently Doped Silica-Based Optical Fibers
/ Kerboub, Nourdine (CERN ; CNES, Toulouse ; Lab. Hubert Curien, St. Etienne) ; Di Francesca, Diego (CERN) ; Morana, Adriana (Lab. Hubert Curien, St. Etienne) ; Hamzaoui, Hicham El (PhLAM, Villeneuve d'Ascq) ; Ouerdane, Youcef (Lab. Hubert Curien, St. Etienne) ; Bouwmans, Géraud (PhLAM, Villeneuve d'Ascq) ; Habert, Rémi (PhLAM, Villeneuve d'Ascq) ; Cassez, Andy (PhLAM, Villeneuve d'Ascq) ; Boukenter, Aziz (Lab. Hubert Curien, St. Etienne) ; Capoen, Bruno (PhLAM, Villeneuve d'Ascq) et al.
We evaluate the temperature effect on the X-ray radiation-induced luminescence (RIL) of differently doped silica fibers obtained via the sol-gel route. Previous investigations showed that these optical materials exhibit interesting dosimetry properties, such as very good detection capabilities and linear response over a large range of dose rate. [...]
2024 - 7 p.
- Published in : IEEE Trans. Nucl. Sci. 71 (2024) 2280-2286
|
|
2.
|
Solar Particle Event Detection With the LUMINA Optical Fiber Dosimeter Aboard the International Space Station
/ Roche, Martin (CNES, Toulouse ; Lab. Hubert Curien, St. Etienne) ; Balcon, Nicolas (CNES, Toulouse) ; Clément, Florence (CNES, Toulouse) ; Cheiney, Pierrick ; Morana, Adriana (Lab. Hubert Curien, St. Etienne) ; Francesca, Diego Di (CERN) ; Jean-Christophe, Malapert (CNES, Toulouse) ; Kerboub, Nourdine (CNES, Toulouse) ; Marot, Lourdes Oro ; Ricci, Daniel (CERN) et al.
LUMINA, a fiber-based dosimeter, exploiting the radiation induced attenuation (RIA) phenomenon, has been operational inside the International Space Station (ISS) since August 2021. We discuss in this article its capability to detect the possible signatures of recent solar particle events (SPEs) through the related increase of the dose rate (DR) radiation level within the ISS. [...]
2024 - 9 p.
- Published in : IEEE Trans. Nucl. Sci.
In : Conference on Radiation and its Effects on Components and Systems (RADECS 2023), Toulouse, France, 25 - 29 Sep 2023, pp.1580-1588
|
|
3.
|
Radiation Induced Attenuation and Luminescence Study in Radioluminescent Optical Fibers
/ Kerboub, Nourdine (CERN ; Lab. Hubert Curien, St. Etienne ; CNES, Toulouse) ; Di Francesca, Diego (CERN) ; Morana, Adriana (Lab. Hubert Curien, St. Etienne) ; El Hamzaoui, Hicham (Lille U.) ; Ouerdane, Youcef (Lab. Hubert Curien, St. Etienne) ; Bouwmans, Géraud (Lille U.) ; Cassez, Andy (Lille U.) ; Boukenter, Aziz (Lab. Hubert Curien, St. Etienne) ; Capoen, Bruno (Lille U.) ; Marin, Emmanuel (Lab. Hubert Curien, St. Etienne) et al.
We present the experimental characterization of both radiation induced attenuation (RIA) and radioluminescence (RL) of differently doped optical fiber (OF) radiation sensors. We present data for different sample lengths and total ionizing dose (TID) up to 600 kGy (SiO2) under X-rays. [...]
2023 - 8 p.
- Published in : IEEE Trans. Nucl. Sci.
Fulltext: PDF;
In : European Conference on Radiation and its Effects on Components and Systems, Venice, Italy, 3 - 7 Oct 2022, pp.1917-1924
|
|
4.
|
|
Mixed-Field Radiation Qualification of a COTS Space On-Board Computer along with its CMOS Camera Payload
/ Coronetti, Andrea (CERN) ; Manni, Florent (CNES, Toulouse) ; Mekki, Julien (CNES, Toulouse) ; Dangla, David (CNES, Toulouse) ; Virmontois, Cedric (CNES, Toulouse) ; Kerboub, Nourdine (CERN) ; Alia, Ruben Garcia (CERN)
The radiation qualification of a complex space
system made out of multiple commercial electronic components
and modules is a non-standardized task with certain limitations,
but also wide potentialities. [...]
2019. - 8 p.
|
|
5.
|
Low radiation dose calibration and theoretical model of an optical fiber dosimeter for the International Space Station
/ Di Francesca, Diego (CERN ; Lab. Hubert Curien, St. Etienne) ; Balcon, Nicolas (CNES, Toulouse) ; Cheiney, Pierrick (IRAM, St. Martin d'Heres) ; Chesta, Enrico (CERN) ; Clement, Florence (CNES, Toulouse) ; Girard, Sylvain (Lab. Hubert Curien, St. Etienne) ; Mekki, Julien (CNES, Toulouse) ; Melin, Gilles (FOTON, Lannion) ; Morana, Adriana (Lab. Hubert Curien, St. Etienne) ; Roche, Martin (Lab. Hubert Curien, St. Etienne ; CNES, Toulouse) et al.
The optical-fiber-based dosimeter of the LUMINA project was deployed in August 2021 in the International Space Station in the framework of the Alpha mission. The sensing elements of the dosimeter are P-doped optical fibers, which were proven to be excellent candidates for dosimetry applications. [...]
2023 - 8 p.
- Published in : Appl. Opt. 62 (2023) E43-E50
Fulltext: PDF;
|
|
6.
|
Operating Temperature Range of Phosphorous-Doped Optical Fiber Dosimeters Exploiting Infrared Radiation-Induced Attenuation
/ Morana, A (Lab. Hubert Curien, St. Etienne) ; Campanella, C (Lab. Hubert Curien, St. Etienne) ; Marin, E (Lab. Hubert Curien, St. Etienne) ; Melin, G (FOTON, Lannion) ; Robin, T (FOTON, Lannion) ; Li Vecchi, G (CERN ; Lab. Hubert Curien, St. Etienne) ; Di Francesca, D (CERN ; Lab. Hubert Curien, St. Etienne) ; Boukenter, A (Lab. Hubert Curien, St. Etienne) ; Ouerdane, Y (Lab. Hubert Curien, St. Etienne) ; Mady, F (INPHYNI, Nice) et al.
Point or distributed optical fiber (OF)-based dosimeters can exploit the observed linear dependence of the radiation-induced attenuation (RIA) at 1550 nm in phosphosilicate OFs to monitor the total ionizing dose (TID). The temperature dependence of the radiation sensitivity coefficients at 1550 nm (expressed in dB km$^{-1}$ Gy$^{-1}$) of three phosphorus-doped single-mode OFs has been investigated between -80 °C and 300 °C for TID ranging from 1 Gy to 1 kGy(SiO$_2$). [...]
2021 - 7 p.
- Published in : IEEE Trans. Nucl. Sci. 68 (2021) 906-912
|
|
7.
|
Temperature Effect on the Radioluminescence of Cu-, Ce-, and CuCe-Doped Silica-Based Fiber Materials
/ Kerboub, Nourdine (CERN ; HCL, Lyon ; CNES, Toulouse) ; Di Francesca, Diego (CERN ; HCL, Lyon) ; Girard, Sylvain (HCL, Lyon) ; Morana, Adriana (Lyon, Ecole Centrale) ; El Hamzaoui, Hicham (Lille U.) ; Ouerdane, Youcef (HCL, Lyon) ; Bouwmans, Géraud (Lille U.) ; Habert, Rémi (Lille U.) ; Boukenter, Aziz (HCL, Lyon) ; Capoen, Bruno (Lille U.) et al.
We evaluate the temperature effect on the X-ray radiation-induced luminescence (RIL) of Cu- or Ce-single-doped and CuCe-codoped silica glass. Previous investigations showed that these optical materials exhibit interesting dosimetry properties, such as very good detection capabilities and linear response over a large range of dose rate. [...]
2021 - 6 p.
- Published in : IEEE Trans. Nucl. Sci. 68 (2021) 1782-1787
|
|
8.
|
Radiation Hardness Assurance Through System-Level Testing: Risk Acceptance, Facility Requirements, Test Methodology, and Data Exploitation
/ Coronetti, Andrea (CERN ; Jyvaskyla U.) ; Garcia Alia, Ruben (CERN) ; Budroweit, Jan (DLR, Bremen) ; Rajkowski, Tomasz (Unlisted, FR) ; Da Costa Lopes, Israel (IES, Montpellier) ; Niskanen, Kimmo (IES, Montpellier) ; Soderstrom, Daniel (Jyvaskyla U.) ; Cazzaniga, Carlo (Rutherford) ; Ferraro, Rudy (CERN) ; Danzeca, Salvatore (CERN) et al.
2021 - 12 p.
- Published in : IEEE Trans. Nucl. Sci. 68 (2021) 958-969
|
|
9.
|
X-Rays, $\gamma$-Rays, and Proton Beam Monitoring With Multimode Nitrogen-Doped Optical Fiber
/ Girard, S (Lyon U.) ; Di Francesca, D (CERN) ; Morana, A (Lyon U.) ; Hoehr, C (TRIUMF) ; Paillet, P (CEA DAM) ; Duzenli, C (Unlisted, CA) ; Kerboub, N (CERN) ; Reghioua, I (Lyon U.) ; Li Vecchi, G (Lyon U. ; CERN) ; Alessi, A (Lyon U.) et al.
We investigated the potential of a multimode
(50-μm core diameter) nitrogen doped silica-based optical fiber
for X-rays, protons, and γ -rays radiation detection and dosimetry. X-rays results confirm that this N-doped fiber presents a
strong radioluminescence (RL) around 550 nm when exposed
to radiation. [...]
2019 - 6 p.
- Published in : IEEE Trans. Nucl. Sci. 66 (2019) 306-311
|
|
10.
|
Atmospheric Neutron Monitoring through Optical Fiber-Based Sensing
/ Girard, Sylvain (Lab. Hubert Curien, St. Etienne) ; Morana, Adriana (Lab. Hubert Curien, St. Etienne) ; Hoehr, Cornelia (TRIUMF) ; Trinczek, Michael (TRIUMF) ; Vidalot, Jeoffray (Lab. Hubert Curien, St. Etienne ; CEA DAM) ; Paillet, Philippe (CEA DAM) ; Bélanger-Champagne, Camille (TRIUMF) ; Mekki, Julien (CNES, Toulouse) ; Balcon, Nicolas (CNES, Toulouse) ; Vecchi, Gaetano Li (Lab. Hubert Curien, St. Etienne ; CERN) et al.
The potential of fiber-based sensors to monitor the fluence of atmospheric neutrons is evaluated through accelerated tests at the TRIUMF Neutron Facility (TNF) (BC, Canada), offering a flux approximatively 10$^9$ higher than the reference spectrum observed under standard conditions in New York City, USA. The radiation-induced attenuation (RIA) at 1625 nm of a phosphorus-doped radiation sensitive optical fiber is shown to linearly increase with neutron fluence, allowing an in situ and easy monitoring of the neutron flux and fluence at this facility. [...]
2020 - 9 p.
- Published in : Sensors 20 (2020) 4510
Fulltext: PDF;
|
|