1.
|
Temperature Effect on the Radioluminescence of Differently Doped Silica-Based Optical Fibers
/ Kerboub, Nourdine (CERN ; CNES, Toulouse ; Lab. Hubert Curien, St. Etienne) ; Di Francesca, Diego (CERN) ; Morana, Adriana (Lab. Hubert Curien, St. Etienne) ; Hamzaoui, Hicham El (PhLAM, Villeneuve d'Ascq) ; Ouerdane, Youcef (Lab. Hubert Curien, St. Etienne) ; Bouwmans, Géraud (PhLAM, Villeneuve d'Ascq) ; Habert, Rémi (PhLAM, Villeneuve d'Ascq) ; Cassez, Andy (PhLAM, Villeneuve d'Ascq) ; Boukenter, Aziz (Lab. Hubert Curien, St. Etienne) ; Capoen, Bruno (PhLAM, Villeneuve d'Ascq) et al.
We evaluate the temperature effect on the X-ray radiation-induced luminescence (RIL) of differently doped silica fibers obtained via the sol-gel route. Previous investigations showed that these optical materials exhibit interesting dosimetry properties, such as very good detection capabilities and linear response over a large range of dose rate. [...]
2024 - 7 p.
- Published in : IEEE Trans. Nucl. Sci. 71 (2024) 2280-2286
|
|
2.
|
Solar Particle Event Detection With the LUMINA Optical Fiber Dosimeter Aboard the International Space Station
/ Roche, Martin (CNES, Toulouse ; Lab. Hubert Curien, St. Etienne) ; Balcon, Nicolas (CNES, Toulouse) ; Clément, Florence (CNES, Toulouse) ; Cheiney, Pierrick ; Morana, Adriana (Lab. Hubert Curien, St. Etienne) ; Francesca, Diego Di (CERN) ; Jean-Christophe, Malapert (CNES, Toulouse) ; Kerboub, Nourdine (CNES, Toulouse) ; Marot, Lourdes Oro ; Ricci, Daniel (CERN) et al.
LUMINA, a fiber-based dosimeter, exploiting the radiation induced attenuation (RIA) phenomenon, has been operational inside the International Space Station (ISS) since August 2021. We discuss in this article its capability to detect the possible signatures of recent solar particle events (SPEs) through the related increase of the dose rate (DR) radiation level within the ISS. [...]
2024 - 9 p.
- Published in : IEEE Trans. Nucl. Sci.
In : Conference on Radiation and its Effects on Components and Systems (RADECS 2023), Toulouse, France, 25 - 29 Sep 2023, pp.1580-1588
|
|
3.
|
Radiation Monitoring With Radiosensitive Pure-Silica Core Ultralow Loss Optical Fiber
/ Weninger, Luca (Lab. Hubert Curien, St. Etienne) ; Morana, Adriana (Lab. Hubert Curien, St. Etienne) ; Campanella, Cosimo (Lab. Hubert Curien, St. Etienne) ; Vidalot, Jeoffray (Lab. Hubert Curien, St. Etienne) ; Marin, Emmanuel (Lab. Hubert Curien, St. Etienne) ; Ouerdane, Youcef (Lab. Hubert Curien, St. Etienne) ; Boukenter, Aziz (Lab. Hubert Curien, St. Etienne) ; Alía, Rubén García (CERN) ; Girard, Sylvain (Lab. Hubert Curien, St. Etienne ; IUF, Paris)
This article presents a new prospect for radiation detection exploiting the high radiation sensitivity of an ultralow-loss pure-silica core optical fiber (ULL-PSCF). This fiber exhibits very high transient X-ray radiation-induced attenuation (RIA) levels from UV to IR during irradiation, while its RIA quickly returns to a low permanent level after irradiation. [...]
2024 - 8 p.
- Published in : IEEE Trans. Nucl. Sci.
Fulltext: PDF;
In : Conference on Radiation and its Effects on Components and Systems (RADECS 2023), Toulouse, France, 25 - 29 Sep 2023, pp.1813-1820
|
|
4.
|
Radiation Induced Attenuation and Luminescence Study in Radioluminescent Optical Fibers
/ Kerboub, Nourdine (CERN ; Lab. Hubert Curien, St. Etienne ; CNES, Toulouse) ; Di Francesca, Diego (CERN) ; Morana, Adriana (Lab. Hubert Curien, St. Etienne) ; El Hamzaoui, Hicham (Lille U.) ; Ouerdane, Youcef (Lab. Hubert Curien, St. Etienne) ; Bouwmans, Géraud (Lille U.) ; Cassez, Andy (Lille U.) ; Boukenter, Aziz (Lab. Hubert Curien, St. Etienne) ; Capoen, Bruno (Lille U.) ; Marin, Emmanuel (Lab. Hubert Curien, St. Etienne) et al.
We present the experimental characterization of both radiation induced attenuation (RIA) and radioluminescence (RL) of differently doped optical fiber (OF) radiation sensors. We present data for different sample lengths and total ionizing dose (TID) up to 600 kGy (SiO2) under X-rays. [...]
2023 - 8 p.
- Published in : IEEE Trans. Nucl. Sci.
Fulltext: PDF;
In : European Conference on Radiation and its Effects on Components and Systems, Venice, Italy, 3 - 7 Oct 2022, pp.1917-1924
|
|
5.
|
Calibration in the Visible and Infrared Domains of Multimode Phosphosilicate Optical Fibers for Dosimetry Applications
/ Weninger, Luca (Lab. Hubert Curien, St. Etienne) ; Campanella, Cosimo (Lab. Hubert Curien, St. Etienne) ; Morana, Adriana (Lab. Hubert Curien, St. Etienne) ; Fricano, Fiammetta (Lab. Hubert Curien, St. Etienne) ; Marin, Emmanuel (Lab. Hubert Curien, St. Etienne) ; Ouerdane, Youcef (Lab. Hubert Curien, St. Etienne) ; Boukenter, Aziz (Lab. Hubert Curien, St. Etienne) ; García Alía, Rubén (CERN) ; Girard, Sylvain (Lab. Hubert Curien, St. Etienne)
We systematically explore the suitability of two radiation-sensitive multimode optical fibers (OFs) with either P or GeP-doped cores to serve as the sensing elements in point or distributed dosimeters. To this end, we measured the dependences of their spectral radiation-induced attenuation (RIA) in the visible and near-infrared (near-IR) domain (400–2100 nm) up to total ionizing dose (TID) of 5 kGy(SiO2) while varying the irradiation temperature from −80 °C to +80 °C and the dose rate between 1 mGy(SiO2)/s and 10 Gy(SiO2)/s. [...]
2023 - 9 p.
- Published in : IEEE Trans. Nucl. Sci.
In : European Conference on Radiation and its Effects on Components and Systems, Venice, Italy, 3 - 7 Oct 2022, pp.1908-1916
|
|
6.
|
Low radiation dose calibration and theoretical model of an optical fiber dosimeter for the International Space Station
/ Di Francesca, Diego (CERN ; Lab. Hubert Curien, St. Etienne) ; Balcon, Nicolas (CNES, Toulouse) ; Cheiney, Pierrick (IRAM, St. Martin d'Heres) ; Chesta, Enrico (CERN) ; Clement, Florence (CNES, Toulouse) ; Girard, Sylvain (Lab. Hubert Curien, St. Etienne) ; Mekki, Julien (CNES, Toulouse) ; Melin, Gilles (FOTON, Lannion) ; Morana, Adriana (Lab. Hubert Curien, St. Etienne) ; Roche, Martin (Lab. Hubert Curien, St. Etienne ; CNES, Toulouse) et al.
The optical-fiber-based dosimeter of the LUMINA project was deployed in August 2021 in the International Space Station in the framework of the Alpha mission. The sensing elements of the dosimeter are P-doped optical fibers, which were proven to be excellent candidates for dosimetry applications. [...]
2023 - 8 p.
- Published in : Appl. Opt. 62 (2023) E43-E50
Fulltext: PDF;
|
|
7.
|
Gd$^{3+}$-doped sol-gel silica glass for remote ionizing radiation dosimetry
/ El hamzaoui, Hicham (Lille U. ; PhLAM, Villeneuve d'Ascq) ; Bouwmans, Géraud (Lille U. ; PhLAM, Villeneuve d'Ascq) ; Capoen, Bruno (Lille U. ; PhLAM, Villeneuve d'Ascq) ; Cassez, Andy (Lille U. ; PhLAM, Villeneuve d'Ascq) ; Habert, Rémi (Lille U. ; PhLAM, Villeneuve d'Ascq) ; Ouerdane, Youcef (Lyon U.) ; Girard, Sylvain (Lyon U.) ; Di francesca, Diego (CERN) ; Kerboub, Nourdine (CERN) ; Morana, Adriana (Lyon U.) et al.
Gadolinium-doped silica glass was prepared, using the sol-gel route, for ionizing radiation dosimetry applications. Such a glassy rod was drawn to a cane at a temperature of 2000 °C. [...]
2019 - 7 p.
- Published in : OSA Continuum 2 (2019) 715-721
Fulltext from publisher: PDF;
|
|
8.
|
Temperature Effect on the Radioluminescence of Cu-, Ce-, and CuCe-Doped Silica-Based Fiber Materials
/ Kerboub, Nourdine (CERN ; HCL, Lyon ; CNES, Toulouse) ; Di Francesca, Diego (CERN ; HCL, Lyon) ; Girard, Sylvain (HCL, Lyon) ; Morana, Adriana (Lyon, Ecole Centrale) ; El Hamzaoui, Hicham (Lille U.) ; Ouerdane, Youcef (HCL, Lyon) ; Bouwmans, Géraud (Lille U.) ; Habert, Rémi (Lille U.) ; Boukenter, Aziz (HCL, Lyon) ; Capoen, Bruno (Lille U.) et al.
We evaluate the temperature effect on the X-ray radiation-induced luminescence (RIL) of Cu- or Ce-single-doped and CuCe-codoped silica glass. Previous investigations showed that these optical materials exhibit interesting dosimetry properties, such as very good detection capabilities and linear response over a large range of dose rate. [...]
2021 - 6 p.
- Published in : IEEE Trans. Nucl. Sci. 68 (2021) 1782-1787
|
|
9.
|
Atmospheric Neutron Monitoring through Optical Fiber-Based Sensing
/ Girard, Sylvain (Lab. Hubert Curien, St. Etienne) ; Morana, Adriana (Lab. Hubert Curien, St. Etienne) ; Hoehr, Cornelia (TRIUMF) ; Trinczek, Michael (TRIUMF) ; Vidalot, Jeoffray (Lab. Hubert Curien, St. Etienne ; CEA DAM) ; Paillet, Philippe (CEA DAM) ; Bélanger-Champagne, Camille (TRIUMF) ; Mekki, Julien (CNES, Toulouse) ; Balcon, Nicolas (CNES, Toulouse) ; Vecchi, Gaetano Li (Lab. Hubert Curien, St. Etienne ; CERN) et al.
The potential of fiber-based sensors to monitor the fluence of atmospheric neutrons is evaluated through accelerated tests at the TRIUMF Neutron Facility (TNF) (BC, Canada), offering a flux approximatively 10$^9$ higher than the reference spectrum observed under standard conditions in New York City, USA. The radiation-induced attenuation (RIA) at 1625 nm of a phosphorus-doped radiation sensitive optical fiber is shown to linearly increase with neutron fluence, allowing an in situ and easy monitoring of the neutron flux and fluence at this facility. [...]
2020 - 9 p.
- Published in : Sensors 20 (2020) 4510
Fulltext: PDF;
|
|
10.
|
Qualification and Calibration of Single-Mode Phosphosilicate Optical Fiber for Dosimetry at CERN
/ Di Francesca, Diego (CERN) ; Li Vecchi, Gaetano (CERN) ; Girard, Sylvain (St. Etienne U.) ; Morana, Adriana (St. Etienne U.) ; Reghioua, Imene (St. Etienne U.) ; Alessi, Antonino (St. Etienne U.) ; Hoehr, Cornelia (TRIUMF) ; Robin, Thierry (Unlisted, FR) ; Kadi, Yacine (CERN) ; Brugger, Markus (CERN)
We report the results of several complementary radiation tests to qualify and calibrate a highly radiation sensitive Single-Mode (SM) Optical Fiber (OF) for distributed dosimetry application at CERN. The Radiation Induced Attenuation (RIA) is the physical phenomenon used to evaluate the Total Ionizing Dose (TID) received by the OF sensor. [...]
2019 - 7 p.
- Published in : J. Lightwave Technol. 37 (2019) 4643-4649
|
|