Report number LHC-Project-Report-863 ; CERN-LHC-Project-Report-863
Title Automatic Management Systems for the Operation of the Cryogenic Test Facilities for LHC Series Superconducting Magnets
Author(s) Tovar-Gonzalez, A ; Axensalva, J ; Herblin, L ; Lamboy, J P ; Vullierme, B
Affiliation (CERN)
Publication 2006
Imprint 11 Jan 2006
Number of pages 9
In: AIP Conf. Proc. 823 (2006) 1227-1234
In: Conference on Cryogenic Engineering and on International Cryogenic Materials, Keystone, CO, USA, 29 Aug - 2 Sep 2005, pp.1227-1234
DOI 10.1063/1.2202541
Subject category Accelerators and Storage Rings
Accelerator/Facility, Experiment CERN LHC
Abstract Prior to their final preparation before installation in the tunnel, the  1800 series superconducting magnets of the LHC machine shall be entirely tested at reception on modular test facilities. The operation 24 hours per day of the cryogenic test facilities is conducted in turn by 3-operator teams, assisted in real time by the use of the Test Bench Priorities Handling System, a process control application enforcing the optimum use of cryogenic utilities and of the "Tasks Tracking System", a web-based e-traveller application handling 12 parallel 38-task test sequences. This paper describes how such computer-based management systems can be used to optimize operation of concurrent test benches within technical boundary conditions given by the cryogenic capacity, and how they can be used to study the efficiency of the automatic steering of all individual cryogenic sub-systems. Finally, this paper presents the overall performance of the cryomagnet test station for the first complete year of operation at high production rate.

Corresponding record in: Inspire
Email contact: [email protected]


 レコード 生成: 2006-02-10, 最終変更: 2023-05-31


Access to fulltext document:
Download fulltextPDF
External link:
Download fulltextPublished version from AIP