主頁 > Performance of a UA1 hadron calorimeter prototype |
Article | |
Title | Performance of a UA1 hadron calorimeter prototype |
Author(s) | Corden, M J ; Arnison, G ; Astbury, A ; Dowell, John D ; Edwards, M ; Eisenhandler, E F ; Ellis, Nick ; Garvey, J ; Gibson, W R ; Grant, D ; Grayer, G ; Haynes, W J ; Hill, D ; Homer, R J ; Kalmus, Peter I P ; Kenyon, I R ; McMahon, T ; Nandi, A K ; Roberts, C ; Schanz, G ; Shah, T P ; Sumorok, K ; Thompson, G ; Watkins, P M ; Wilson, J A |
Affiliation | (Dept of Phys, Univ of Birmingham, Birmingham, UK) |
Publication | 1982 |
In: | Phys. Scr. 25 (1982) 11-14 |
In: | International Conference on Experimentation at LEP, pp.11-14 |
DOI | 10.1088/0031-8949/25/1A/002 |
Subject category | Nuclear Physics |
Abstract | The hadron calorimeter for the UA1 experiment at the CERN SPS proton- antiproton collider consists of a lead-scintillator sandwich plus an iron-scintillator sandwich with wavelength shifter readout. The authors have tested prototype modules in muon and hadron beams in the momentum range from 0.7 to 90 GeV/c. For several angles of incidence, they have studied the uniformity of the response to hadrons as a function of position. This has included regions where there is reduced sensitivity due to mechanical constraints and the presence of the wavelength shifter readout. The response, resolution and degree of shower containment were measured as a function of incident momentum. |