CERN Accelerating science

Article
Report number arXiv:1909.12604
Title Timing Performance of a Micro-Channel-Plate Photomultiplier Tube
Author(s) Bortfeldt, Jonathan (CERN) ; Brunbauer, F. (CERN) ; David, C. (CERN) ; Desforge, D. (IRFU, Saclay) ; Fanourakis, G. (Democritos Nucl. Res. Ctr.) ; Gallinaro, M. (LIP, Lisbon) ; Garcıa, F. (Helsinki U.) ; Giomataris, I. (IRFU, Saclay) ; Gustavsson, T. (LIDYL, Saclay) ; Guyot, C. (IRFU, Saclay) ; Iguaz, F.J. (IRFU, Saclay) ; Kebbiri, M. (IRFU, Saclay) ; Kordas, K. (Aristotle U., Thessaloniki) ; Legou, P. (IRFU, Saclay) ; Liu, J. (CUST, SKLPDE) ; Lupberger, M. (CERN) ; Manthos, I. (Aristotle U., Thessaloniki) ; Muller, H. (CERN) ; Niaouris, V. (Aristotle U., Thessaloniki) ; Oliveri, E. (CERN) ; Papaevangelou, T. (IRFU, Saclay) ; Paraschou, K. (Aristotle U., Thessaloniki) ; Pomorski, M. (LIST, Saclay) ; Resnati, F. (CERN) ; Ropelewski, L. (CERN) ; Sampsonidis, D. (Aristotle U., Thessaloniki) ; Schneider, T. (CERN) ; Schwemling, P. (IRFU, Saclay) ; Scorsone, E. (LIST, Saclay) ; Sohl, L. (IRFU, Saclay) ; van Stenis, M. (CERN) ; Thuiner, P. (CERN) ; Tsipolitis, Y. (Natl. Tech. U., Athens) ; Tzamarias, S.E. (Aristotle U., Thessaloniki) ; Veenhof, R. (CERN) ; Wang, X. (CUST, SKLPDE) ; White, S. (CERN) ; Zhang, Z. (CUST, SKLPDE) ; Zhou, Y. (CUST, SKLPDE)
Publication 2020-04-21
Imprint 2019-09-27
Number of pages 6
Note 6 figures
In: Nucl. Instrum. Methods Phys. Res., A 960 (2020) 163592
DOI 10.1016/j.nima.2020.163592
Subject category physics.ins-det ; Detectors and Experimental Techniques
Abstract The spatial dependence of the timing performance of the R3809U-50 Micro-Channel-Plate PMT (MCP-PMT) by Hamamatsu was studied in high energy muon beams. Particle position information is provided by a GEM tracker telescope, while timing is measured relative to a second MCP-PMT, identical in construction. In the inner part of the circular active area (radius r$<$5.5\,mm) the time resolution of the two MCP-PMTs combined is better than 10 ps. The signal amplitude decreases in the outer region due to less light reaching the photocathode, resulting in a worse time resolution. The observed radial dependence is in quantitative agreement with a dedicated simulation. With this characterization, the suitability of MCP-PMTs as $\text{t}_\text{0}$ reference detectors has been validated.
Copyright/License publication: © 2020-2024 The Authors (License: CC-BY-4.0)
preprint: (License: arXiv nonexclusive-distrib 1.0)



Corresponding record in: Inspire


 Datensatz erzeugt am 2019-12-11, letzte Änderung am 2023-03-14


Fulltext from Publisher:
Volltext herunterladenPDF
Published fulltext:
1-s2.0-S0168900220301613-main - Volltext herunterladenPDF
a51dae9a2ef3e2858edfe138fb2dec2d - Volltext herunterladenPDF
Volltext:
Volltext herunterladenPDF