Accueil > Use of a Massless Septum to Increase Slow-Extraction Efficiency |
Published Articles | |
Title | Use of a Massless Septum to Increase Slow-Extraction Efficiency |
Author(s) | Brunner, Kristóf (Wigner RCP, Budapest) ; Barna, Daniel (Wigner RCP, Budapest) ; Fraser, Matthew (CERN) ; Goddard, Brennan (CERN) ; Stoel, Linda (CERN ; TU Vienna) ; Wiesner, Christoph (CERN) |
Publication | 2018 |
Number of pages | 4 |
In: | 9th International Particle Accelerator Conference, Vancouver, Canada, 29 Apr - 4 May 2018, pp.TUPAF061 |
DOI | 10.18429/JACoW-IPAC2018-TUPAF061 |
Subject category | Accelerators and Storage Rings |
Abstract | The Super Proton Synchrotron (SPS) at CERN provides slow-extracted beam for Fixed Target experiments in the North Area. For the higher extracted beam intensities requested by future experimental proposals, beam-loss induced activation will be one of the limiting factors for the availability of such a facility. In this paper, we present and discuss the concept of using a massless septum magnet to increase the extraction efficiency and decrease losses caused by protons scattering on the electrostatic-septa wires. |
Copyright/License | CC-BY-3.0 |