Hauptseite > CMS Collection > CMS Preprints > Low temperature characteristics of SiPMs after very high neutron irradiation |
Published Articles | |
Title | Low temperature characteristics of SiPMs after very high neutron irradiation |
Related title | Low temperature characteristics of SiPMs after very high neutron irradiation |
Author(s) | Heering, A ; Musienko, Yu ; Gonzales, J (CERN) ; Karneyeu, A ; Wayne, M ; Ruchti, R ; Moll, M |
Publication | 2019 |
In: | Nucl. Instrum. Meth. A 936 (2019) 671-673 |
DOI | 10.1016/j.nima.2018.09.111 |
Subject category | Detectors and Experimental Techniques ; Detectors and Experimental Techniques |
Accelerator/Facility, Experiment | CERN LHC ; CMS |
Abstract | The design of the CMS phase II upgrade for the HL-LHC uses SiPMs for the Barrel Timing Layer (BTL) and the Behind HCAL detector (BH or CEH). In both sub-detectors the SiPMs will see a 1 MeV equivalent dose of around n/cm. To lower the noise in the SiPMs the design is to keep the SiPMs at a low temperature of −30 C. Different samples from two manufactures of SiPMs were irradiated to a total dose of resp. 2 , 5 at the TRIGA reactor at the JSI in Slovenia. The noise in SiPMs is dominated by trap assisted tunneling which is a result of the high internal electric field in SiPMs. We therefore studied the noise behavior from +10 C to −40 C from standard high internal field and specially designed low field SiPMs from FBK-irst and Hamamatsu. After the initial characterization before annealing the noise decrease in SiPMs was also studied using accelerated annealing. |
Copyright/License | publication: © 2018 Elsevier B.V. (License: CC-BY-4.0) |