CERN Accelerating science

Published Articles
Title Low temperature characteristics of SiPMs after very high neutron irradiation
Related titleLow temperature characteristics of SiPMs after very high neutron irradiation
Author(s) Heering, A ; Musienko, Yu ; Gonzales, J (CERN) ; Karneyeu, A ; Wayne, M ; Ruchti, R ; Moll, M
Publication 2019
In: Nucl. Instrum. Meth. A 936 (2019) 671-673
DOI 10.1016/j.nima.2018.09.111
Subject category Detectors and Experimental Techniques ; Detectors and Experimental Techniques
Accelerator/Facility, Experiment CERN LHC ; CMS
Abstract The design of the CMS phase II upgrade for the HL-LHC uses SiPMs for the Barrel Timing Layer (BTL) and the Behind HCAL detector (BH or CEH). In both sub-detectors the SiPMs will see a 1 MeV equivalent dose of around n/cm. To lower the noise in the SiPMs the design is to keep the SiPMs at a low temperature of −30 C. Different samples from two manufactures of SiPMs were irradiated to a total dose of resp. 2 , 5 at the TRIGA reactor at the JSI in Slovenia. The noise in SiPMs is dominated by trap assisted tunneling which is a result of the high internal electric field in SiPMs. We therefore studied the noise behavior from +10 C to −40 C from standard high internal field and specially designed low field SiPMs from FBK-irst and Hamamatsu. After the initial characterization before annealing the noise decrease in SiPMs was also studied using accelerated annealing.
Copyright/License publication: © 2018 Elsevier B.V. (License: CC-BY-4.0)

Corresponding record in: Inspire


 Datensatz erzeugt am 2019-03-06, letzte Änderung am 2022-08-10


Fulltext from Publisher:
Volltext herunterladen
PDF