Title Characterization of a new charge sensitive preamplifier (CSP) for the electromagnetic calorimeters of the ALICE experiment
Author(s) Wang, Ya-Ping (Hua-Zhong Normal U. ; Hua-Zhong Normal U., LQLP) ; Muller, Hans (CERN) ; Cai, Xu (Hua-Zhong Normal U. ; Hua-Zhong Normal U., LQLP) ; Zhou, Daicui (Hua-Zhong Normal U. ; Hua-Zhong Normal U., LQLP) ; Awes, Terry C (Oak Ridge) ; Yin, Zhong-Bao (Hua-Zhong Normal U. ; Hua-Zhong Normal U., LQLP)
Publication 2012
Imprint 2012
Number of pages 7
In: Nucl. Instrum. Methods Phys. Res., A 687 (2012) 75-81
DOI 10.1016/j.nima.2012.05.094
Subject category Detectors and Experimental Techniques
Accelerator/Facility, Experiment CERN LHC ; ALICE
Abstract The ALICE calorimeters PHOS and EMCal (including its extension DCal) are based on Avalanche Photo-Diode (APD) photosensors with Charge Sensitive Preamplifiers (CSPs) for readout of the scintillating elements. A new CSP has been developed on the basis of the design of the PHOS CSP, but modified to meet the requirements of the EMCal and DCal. Modifications were made specifically for a different APD choice with different characteristics, and also with the goals of less noise, faster rise time, and reduced cost. This paper presents a detailed description of the new CSP features and the test results.

Corresponding record in: Inspire


 Записът е създаден на 2013-07-04, последна промяна на 2016-06-29