Pàgina inicial > Performance of the Time Resolved Spectrometer for the 5 MeV Photo-Injector PHIN |
Article | |
Report number | CERN-BE-2011-013 |
Title | Performance of the Time Resolved Spectrometer for the 5 MeV Photo-Injector PHIN |
Author(s) | Olvegaard, M (CERN) ; Egger, D (CERN) ; Mete, O (CERN) ; Csatari, M (CERN) ; Dabrowski, A (CERN) ; Dobert, S (CERN) ; Lefevre, T (CERN) ; Petrarca, M (CERN) |
Publication | 2011 |
Imprint | 01 May 2011 |
Number of pages | 3 |
In: | Conf. Proc. C11-05-16.4 (2011) pp.TUPD55 |
In: | 10th European Workshop on Beam Diagnostics and Instrumentation for Particle Accelerators, Hamburg, Germany, 16 - 18 May 2011, pp.431 |
Subject category | Accelerators and Storage Rings |
Free keywords | OTR Screens ; PHIN photo-injector ; CTF3 |
Abstract | The PHIN photo-injector test facility is being commissioned at CERN to demonstrate the capability to produce the required beam for the 3rd CLIC Test Facility (CTF3), which includes the production of a 3.5A stable beam, bunched at 1.5 GHz with a relative energy spread of less than 1%. A 90◦ spectrometer is instrumented with an OTR screen coupled to a gated intensified camera, followed by a segmented beam dump for time resolved energy measurements. The following paper describes the transverse and temporal resolution of the instrumentation with an outlook towards single-bunch energy measurements. |