Skip to main content

Showing 1–14 of 14 results for author: Dadgar, M

Searching in archive physics. Search in all archives.
.
  1. arXiv:2408.00574  [pdf

    physics.med-ph

    Investigation of Novel Preclinical Total Body PET Designed With J-PET Technology:A Simulation Study

    Authors: M. Dadgar, S. Parzych, F. Tayefi Ardebili, J. Baran, N. Chug, C. Curceanu, E. Czerwinski, K. Dulski, K. Eliyan, A. Gajos, B. C. Hiesmayr, K. Kacprzak, L. Kaplon, K. Klimaszewski, P. Konieczka, G. Korcyl, T. Kozik, W. Krzemien, D. Kumar, S. Niedzwiecki, D. Panek, E. Perez del Rio, L. Raczynski, S. Sharma, Shivani , et al. (7 additional authors not shown)

    Abstract: The growing interest in human-grade total body positron emission tomography (PET) systems has also application in small animal research. Due to the existing limitations in human-based studies involving drug development and novel treatment monitoring, animal-based research became a necessary step for testing and protocol preparation. In this simulation-based study two unconventional, cost-effective… ▽ More

    Submitted 6 August, 2024; v1 submitted 1 August, 2024; originally announced August 2024.

  2. arXiv:2407.19465  [pdf

    physics.ins-det nucl-ex

    Comparative studies of plastic scintillator strips with high technical attenuation length for the total-body J-PET scanner

    Authors: L. Kaplon, J. Baran, N. Chug, A. Coussat, C. Curceanu, E. Czerwinski, M. Dadgar, K. Dulski, J. Gajewski, A. Gajos, B. Hiesmayr, E. Kavya Valsan, K. Klimaszewski, G. Korcyl, T. Kozik, W. Krzemien, D. Kumar, G. Moskal, S. Niedzwiecki, D. Panek, S. Parzych, E. Perez del Rio, L. Raczynski, A. Rucinski, S. Sharma , et al. (9 additional authors not shown)

    Abstract: Plastic scintillator strips are considered as one of the promising solutions for the cost-effective construction of total-body positron emission tomography, (PET) system. The purpose of the performed measurements is to compare the transparency of long plastic scintillators with dimensions 6 mm x 24 mm x 1000 mm and with all surfaces polished. Six different types of commercial, general purpose, blu… ▽ More

    Submitted 3 August, 2024; v1 submitted 28 July, 2024; originally announced July 2024.

    Comments: 10 pages, 5 figures

    Journal ref: Nuclear Inst. and Methods in Physics Research, A 1051 (2023) 168186

  3. arXiv:2309.07171  [pdf, other

    physics.ins-det nucl-ex

    Feasibility studies for imaging e$^{+}$e$^{-}$ annihilation with modular multi-strip detectors

    Authors: S. Sharma, L. Povolo, S. Mariazzi, G. Korcyl, K. Kacprzak, D. Kumar, S. Niedzwiecki, J. Baran, E. Beyene, R. S. Brusa, R. Caravita, N. Chug, A. Coussat, C. Curceanu, E. Czerwinski, M. Dadgar, M. Das, K. Dulski, K. Eliyan, A. Gajos, N. Gupta, B. C. Hiesmayr, L. Kaplon, T. Kaplanoglu, K. Klimaszewski , et al. (19 additional authors not shown)

    Abstract: Studies based on imaging the annihilation of the electron (e$^{-}$) and its antiparticle positron (e$^{+}$) open up several interesting applications in nuclear medicine and fundamental research. The annihilation process involves both the direct conversion of e$^{+}$e$^{-}$ into photons and the formation of their atomically bound state, the positronium atom (Ps), which can be used as a probe for fu… ▽ More

    Submitted 12 September, 2023; originally announced September 2023.

  4. arXiv:2304.05834  [pdf

    physics.med-ph

    Comparative studies of the sensitivities of sparse and full geometries of Total-Body PET scanners built from crystals and plastic scintillators

    Authors: Meysam Dadgar, Szymon Parzych, Jakub Baran, Neha Chug, Catalina Curceanu, Eryk Czerwiński, Kamil Dulski, Kavya Elyan, Aleksander Gajos, Beatrix Hiesmayr, Łukasz Kapłon, Konrad Klimaszewski, Paweł Konieczka, Grzegorz Korcyl, Tomasz Kozik, Wojciech Krzemień, Deepak Kumar, Szymon Niedźwiecki, Domonik Panek, Eleną Perez del Rio, Lech Raczyński, Sushil Sharma, Shivani, Roman Shopa, Magdalena Skurzok , et al. (6 additional authors not shown)

    Abstract: Background: Total-Body imaging offers high sensitivity, single-bed position, and low dose, but high construction costs limit worldwide utilization. This study compares existing and developing tomographs using plastic scintillators via simulations to propose a cost-efficient Total-Body PET scanner. Methods: Simulations of eight uEXPLORER tomographs with different scintillator materials, axial fie… ▽ More

    Submitted 12 April, 2023; originally announced April 2023.

  5. arXiv:2302.14359  [pdf, other

    physics.med-ph

    Feasibility of the J-PET to monitor range of therapeutic proton beams

    Authors: Jakub Baran, Damian Borys, Karol Brzeziński, Jan Gajewski, Michał Silarski, Neha Chug, Aurélien Coussat, Eryk Czerwiński, Meysam Dadgar, Kamil Dulski, Kavya V. Eliyan, Aleksander Gajos Krzysztof Kacprzak, Łukasz Kapłon, Konrad Klimaszewski, Paweł Konieczka, Renata Kopeć, Grzegorz Korcyl, Tomasz Kozik, Wojciech Krzemień, Deepak Kumar, Antony J. Lomax, Keegan McNamara, Szymon Niedźwiecki, Paweł Olko, Dominik Panek , et al. (18 additional authors not shown)

    Abstract: Objective: The aim of this work is to investigate the feasibility of the Jagiellonian Positron Emission Tomography (J-PET) scanner for intra-treatment proton beam range monitoring. Approach: The Monte Carlo simulation studies with GATE and PET image reconstruction with CASToR were performed in order to compare six J-PET scanner geometries (three dual-heads and three cylindrical). We simulated prot… ▽ More

    Submitted 28 February, 2023; originally announced February 2023.

    Comments: 19 pages, 7 pages

  6. arXiv:2302.02967  [pdf, other

    physics.med-ph physics.comp-ph physics.ins-det

    TOF MLEM Adaptation for the Total-Body J-PET with a Realistic Analytical System Response Matrix

    Authors: R. Y. Shopa, J. Baran, K. Klimaszewski, W. Krzemień, L. Raczyński, W. Wiślicki, K. Brzeziński, N. Chug, A. Coussat, C. Curceanu, E. Czerwiński, M. Dadgar, K. Dulski, J. Gajewski, A. Gajos, B. C. Hiesmayr, E. Kavya Valsan, G. Korcyl, T. Kozik, D. Kumar, Ł. Kapłon, G. Moskal, S. Niedźwiecki, D. Panek, S. Parzych , et al. (10 additional authors not shown)

    Abstract: We report a study of the original image reconstruction algorithm based on the time-of-flight maximum likelihood expectation maximisation (TOF MLEM), developed for the total-body (TB) Jagiellonian PET (J-PET) scanners. The method is applicable to generic cylindrical or modular multi-layer layouts and is extendable to multi-photon imaging. The system response matrix (SRM) is represented as a set of… ▽ More

    Submitted 8 August, 2024; v1 submitted 6 February, 2023; originally announced February 2023.

    Journal ref: IEEE Transactions on Radiation and Plasma Medical Sciences 7(5) (2023) 509-520

  7. J-PET detection modules based on plastic scintillators for performing studies with positron and positronium beams

    Authors: S. Sharma, J. Baran, R. S. Brusa, R. Caravita, N. Chug, A. Coussat, C. Curceanu, E. Czerwinski, M. Dadgar, K. Dulski, K. Eliyan, A. Gajos, B. C. Hiesmayr, K. Kacprzak, L. Kaplon, K. Klimaszewski, P. Konieczka, G. Korcyl, T. Kozik, W. Krzemien, D. Kumar, S. Mariazzi, S. Niedzwiecki, L. Panasa, S. Parzych , et al. (11 additional authors not shown)

    Abstract: The J-PET detector, which consists of inexpensive plastic scintillators, has demonstrated its potential in the study of fundamental physics. In recent years, a prototype with 192 plastic scintillators arranged in 3 layers has been optimized for the study of positronium decays. This allows performing precision tests of discrete symmetries (C, P, T) in the decays of positronium atoms. Moreover, than… ▽ More

    Submitted 7 January, 2023; originally announced January 2023.

  8. arXiv:2212.02285  [pdf, other

    physics.med-ph physics.ins-det

    Realistic Total-Body J-PET Geometry Optimization -- Monte Carlo Study

    Authors: Jakub Baran, Wojciech Krzemien, Lech Raczyński, Mateusz Bała, Aurelien Coussat, Szymon Parzych, Neha Chug, Eryk Czerwiński, Catalina Oana Curceanu, Meysam Dadgar, Kamil Dulski, Kavya Eliyan, Jan Gajewski, Aleksander Gajos, Beatrix Hiesmayr, Krzysztof Kacprzak, Łukasz Kapłon, Konrad Klimaszewski, Grzegorz Korcyl, Tomasz Kozik, Deepak Kumar, Szymon Niedźwiecki, Dominik Panek, Elena Perez del Rio, Antoni Ruciński , et al. (9 additional authors not shown)

    Abstract: Total-Body PET is one of the most promising medical diagnostics modalities. The high sensitivity provided by Total-Body technology can be advantageous for novel tomography methods like positronium imaging. Several efforts are ongoing to lower the price of the TB-PET systems. Among the alternatives, the Jagiellonian PET (J-PET) technology, based on plastic scintillator strips, offers a low-cost alt… ▽ More

    Submitted 16 February, 2024; v1 submitted 5 December, 2022; originally announced December 2022.

  9. arXiv:2112.08741  [pdf

    physics.med-ph physics.bio-ph

    Positronium imaging with the novel multiphoton PET scanner

    Authors: Paweł Moskal, Kamil Dulski, Neha Chug, Catalina Curceanu, Eryk Czerwiński, Meysam Dadgar, Jan Gajewski, Aleksander Gajos, Grzegorz Grudzień, Beatrix C. Hiesmayr, Krzysztof Kacprzak, Łukasz Kapłon, Hanieh Karimi, Konrad Klimaszewski, Grzegorz Korcyl, Paweł Kowalski, Tomasz Kozik, Nikodem Krawczyk, Wojciech Krzemień, Ewelina Kubicz, Piotr Małczak, Szymon Niedźwiecki, Monika Pawlik-Niedźwiecka, Michał Pędziwiatr, Lech Raczyński , et al. (11 additional authors not shown)

    Abstract: In vivo assessment of cancer and precise location of altered tissues at initial stages of molecular disorders are important diagnostic challenges. Positronium is copiously formed in the free molecular spaces in the patient's body during positron emission tomography (PET). The positronium properties vary according to the size of inter- and intramolecular voids and the concentration of molecules in… ▽ More

    Submitted 16 December, 2021; originally announced December 2021.

    Comments: 10 pages, 5 figures

    Journal ref: Science Advances 7 (2021) eabh4394

  10. arXiv:2107.12750  [pdf, other

    physics.med-ph physics.comp-ph physics.ins-det

    Optimisation of the event-based TOF filtered back-projection for online imaging in total-body J-PET

    Authors: R. Y. Shopa, K. Klimaszewski, P. Kopka, P. Kowalski, W. Krzemień, L. Raczyński, W. Wiślicki, N. Chug, C. Curceanu, E. Czerwiński, M. Dadgar, K. Dulski, A. Gajos, B. C. Hiesmayr, K. Kacprzak, Ł. Kapłon, D. Kisielewska, G. Korcyl, N. Krawczyk, E. Kubicz, Sz. Niedźwiecki, J. Raj, S. Sharma, Shivani, E. L. Stȩpień , et al. (2 additional authors not shown)

    Abstract: We perform a parametric study of the newly developed time-of-flight (TOF) image reconstruction algorithm, proposed for the real-time imaging in total-body Jagiellonian PET (J-PET) scanners. The asymmetric 3D filtering kernel is applied at each most likely position of electron-positron annihilation, estimated from the emissions of back-to-back $γ$-photons. The optimisation of its parameters is stud… ▽ More

    Submitted 27 July, 2021; originally announced July 2021.

  11. arXiv:2107.01356  [pdf, other

    physics.ins-det physics.med-ph

    Simulating NEMA characteristics of the modular total-body J-PET scanner -- an economic total-body PET from plastic scintillators

    Authors: Paweł Moskal, Paweł Kowalski, Roman Shopa, Lech Raczyński, Jakub Baran, Neha Chug, Catalina Curceanu, Eryk Czerwiński, Meysam Dadgar, Kamil Dulski, Aleksander Gajos, Beatrix Hiesmayr, Krzysztof Kacprzak, Łukasz Kapłon, Daria Kisielewska, Konrad Klimaszewski, Przemysław Kopka, Gregorz Korcyl, Nikodem Krawczyk, Wojciech Krzemień, Ewelina Kubicz, Szymon Niedźwiecki, Szymon Parzych, Juhi Raj, Sushil Sharma , et al. (4 additional authors not shown)

    Abstract: The purpose of the presented research is estimation of the performance characteristics of the economic Total-Body Jagiellonian-PET system (TB-J-PET) constructed from plastic scintillators. The characteristics are estimated according to the NEMA NU-2-2018 standards utilizing the GATE package. The simulated detector consists of 24 modules, each built out of 32 plastic scintillator strips (each with… ▽ More

    Submitted 3 July, 2021; originally announced July 2021.

    Comments: 31 pages, 11 figures, 6 tables, submitted to Physics in Medicine and Biology 2021

  12. arXiv:2008.10868  [pdf, other

    physics.ins-det physics.med-ph

    Synchronisation and calibration of the 24-modules J-PET prototype with 300~mm axial field of view

    Authors: P. Moskal, T. Bednarski, Sz. Niedzwiecki, M. Silarski, E. Czerwinski, T. Kozik, J. Chhokar, M. Bała, C. Curceanu, R. Del Grande, M. Dadgar, K. Dulski, A. Gajos, M. Gorgol, N. Gupta-Sharma, B. C. Hiesmayr, B. Jasinska, K. Kacprzak, L. Kaplon, H. Karimi, D. Kisielewska, K. Klimaszewski, G. Korcyl, P. Kowalski, N. Krawczyk , et al. (14 additional authors not shown)

    Abstract: Research conducted in the framework of the J-PET project aims to develop a cost-effective total-body positron emission tomography scanner. As a first step on the way to construct a full-scale J-PET tomograph from long strips of plastic scintillators, a 24-strip prototype was built and tested. The prototype consists of detection modules arranged axially forming a cylindrical diagnostic chamber with… ▽ More

    Submitted 25 August, 2020; originally announced August 2020.

    Comments: Accepted for publication in IEEE Transactions on Instrumentation and Measurement

  13. arXiv:2006.07467  [pdf, other

    physics.ins-det nucl-ex

    The J-PET detector -- a tool for precision studies of ortho-positronium decays

    Authors: K. Dulski, S. D. Bass, J. Chhokar, N. Chug, C. Curceanu, E. Czerwiński, M. Dadgar, J. Gajewski, A. Gajos, M. Gorgol, R. Del Grande, B. C. Hiesmayr, B. Jasińska, K. Kacprzak, Ł. Kapłon, H. Karimi, D. Kisielewska, K. Klimaszewski, P. Kopka, G. Korcyl, P. Kowalski, T. Kozik, N. Krawczyk, W. Krzemień, E. Kubicz , et al. (19 additional authors not shown)

    Abstract: The J-PET tomograph is constructed from plastic scintillator strips arranged axially in concentric cylindrical layers. It enables investigations of positronium decays by measurement of the time, position, polarization and energy deposited by photons in the scintillators, in contrast to studies conducted so far with crystal and semiconductor based detection systems where the key selection of events… ▽ More

    Submitted 25 May, 2021; v1 submitted 9 June, 2020; originally announced June 2020.

    Comments: 12 pages, 7 figures

  14. arXiv:1911.12059  [pdf, other

    physics.ins-det physics.med-ph

    Estimating relationship between the Time Over Threshold and energy loss by photons in plastic scintillators used in the J-PET scanner

    Authors: S. Sharma, J. Chhokar, C. Curceanu, E. Czerwinski, M. Dadgar, K. Dulski, J. Gajewski, A. Gajos, M. Gorgol, N. Gupta-Sharma, R. Del Grande, B. C. Hiesmayr, B. Jasinska, K. Kacprzak, L. Kaplon, H. Karimi, D. Kisielewska, K. Klimaszewski, G. Korcyl, P. Kowalski, T. Kozik, N. Krawczyk, W. Krzemien, E. Kubicz, M. Mohammed , et al. (14 additional authors not shown)

    Abstract: Time-Over-Threshold (TOT) technique is being used widely due to its implications in developing the multi channel readouts mainly when fast signal processing is required. Using TOT technique as a measure of energy loss instead of charge integration methods significantly reduces the signals readout cost by combining the time and energy information. Therefore, this approach can potentially be used in… ▽ More

    Submitted 27 November, 2019; originally announced November 2019.