Skip to main content

Showing 1–13 of 13 results for author: Battistoni, G

Searching in archive physics. Search in all archives.
.
  1. arXiv:2010.16251  [pdf, other

    physics.ins-det nucl-ex

    The FragmentatiOn Of Target Experiment (FOOT) and its DAQ system

    Authors: Silvia Biondi, Andrey Alexandrov, Behcet Alpat, Giovanni Ambrosi, Stefano Argirò, Rau Arteche Diaz, Nazarm Bartosik, Giuseppe Battistoni, Nicola Belcari, Elettra Bellinzona, Maria Giuseppina Bisogni, Graziano Bruni, Pietro Carra, Piergiorgio Cerello, Esther Ciarrocchi, Alberto Clozza, Sofia Colombi, Giovanni De Lellis, Alberto Del Guerra, Micol De Simoni, Antonia Di Crescenzo, Benedetto Di Ruzza, Marco Donetti, Yunsheng Dong, Marco Durante , et al. (70 additional authors not shown)

    Abstract: The FragmentatiOn Of Target (FOOT) experiment aims to provide precise nuclear cross-section measurements for two different fields: hadrontherapy and radio-protection in space. The main reason is the important role the nuclear fragmentation process plays in both fields, where the health risks caused by radiation are very similar and mainly attributable to the fragmentation process. The FOOT experim… ▽ More

    Submitted 29 October, 2020; originally announced October 2020.

  2. Investigations on physical and biological range uncertainties in Krakow proton beam therapy centre

    Authors: Antoni Rucinski, Jakub Baran, Giuseppe Battistoni, Agnieszka Chrostowska, Marco Durante, Jan Gajewski, Magdalena Garbacz, Kamil Kisielewicz, Nils Krah, Vincenzo Patera, Monika Pawlik-Niedźwiecka, Ilaria Rinaldi, Bozena Rozwadowska-Bogusz, Emanuele Scifoni, Agata Skrzypek, Francesco Tommasino, Angelo Schiavi, Pawel Moskal

    Abstract: Physical and biological range uncertainties limit the clinical potential of Proton Beam Therapy (PBT). In this proceedings, we report on two research projects, which we are conducting in parallel and which both tackle the problem of range uncertainties. One aims at developing software tools and the other at developing detector instrumentation. Regarding the first, we report on our development and… ▽ More

    Submitted 25 October, 2019; originally announced October 2019.

    Comments: Accepted for publication in Acta Physica Polonica B. Presented at 3rd Jagiellonian Symposium on Fundamental and Applied Subatomic Physics, June 23 - 28, 2019 in Collegium Maius, Krakow, Poland

  3. Analysis of time-profiles with in-beam PET monitoring in charged particle therapy

    Authors: A. C. Kraan, S. Muraro, G. Battistoni, N. Belcari, M. G. Bisogni, N. Camarlinghi, A. Del Guerra, A. Ferrari, R. Kopec, D. Krzempek, M. Morrocchi, P. Olko, P. Sala, K. Skowronska, G. Sportelli, A. Topi, V. Rosso

    Abstract: Background: Treatment verification with PET imaging in charged particle therapy is conventionally done by comparing measurements of spatial distributions with Monte Carlo (MC) predictions. However, decay curves can provide additional independent information about the treatment and the irradiated tissue. Most studies performed so far focus on long time intervals. Here we investigate the reliability… ▽ More

    Submitted 28 September, 2018; originally announced September 2018.

    Comments: 9 pages, 5 figures, 1 table. Proceedings of the 20th International Workshop on Radiation Imaging Detectors (iWorid2018), 24-28 June 2018, Sundsvall, Sweden

  4. Secondary radiation measurements for particle therapy applications: nuclear fragmentation produced by $^4$He ion beams in a PMMA target

    Authors: M. Marafini, R. Paramatti, D. Pinci, G. Battistoni, F. Collamati, E. De Lucia, R. Faccini, P. M. Frallicciardi, C. Mancini-Terracciano, I. Mattei, S. Muraro, L. Piersanti, M. Rovituso, A. Rucinski, A. Russomando, A. Sarti, A. Sciubba, E. Solfaroli Camillocci, M. Toppi, G. Traini, C. Voena, V. Patera

    Abstract: Nowadays there is a growing interest in Particle Therapy treatments exploiting light ion beams against tumors due to their enhanced Relative Biological Effectiveness and high space selectivity. In particular promising results are obtained by the use of $^4$He projectiles. Unlike the treatments performed using protons, the beam ions can undergo a fragmentation process when interacting with the atom… ▽ More

    Submitted 29 August, 2016; originally announced August 2016.

  5. arXiv:1608.04624  [pdf, other

    physics.med-ph

    Secondary radiation measurements for particle therapy applications: Charged secondaries produced by 4He and 12C ion beams in a PMMA target at large angle

    Authors: A. Rucinski, E. De Lucia, G. Battistoni, F. Collamati, R. Faccini, P. M. Frallicciardi, C. Mancini-Terracciano, M. Marafini, I. Mattei, S. Muraro, R. Paramatti, L. Piersanti, D. Pinci, A. Russomando, A. Sarti, A. Sciubba, E. Solfaroli Camillocci, M. Toppi, G. Traini, C. Voena, V. Patera

    Abstract: Measurements performed with the purpose of characterizing the charged secondary radiation for dose release monitoring in particle therapy are reported. Charged secondary yields, energy spectra and emission profiles produced in poly-methyl methacrylate (PMMA) target by 4He and 12C beams of different therapeutic energies were measured at 60 and 90 degree with respect to the primary beam direction. T… ▽ More

    Submitted 16 August, 2016; originally announced August 2016.

    Comments: 19 pages, 26 Figures

  6. arXiv:1607.08493  [pdf, other

    physics.med-ph physics.ins-det

    Design of a new tracking device for on-line dose monitor in ion therapy

    Authors: Giacomo Traini, Giuseppe Battistoni, Angela Bollella, Francesco Collamati, Erika De Lucia, Riccardo Faccini, Fernando Ferroni, Paola Maria Frallicciardi, Carlo Mancini-Terracciano, Michela Marafini, Ilaria Mattei, Federico Miraglia, Silvia Muraro, Riccardo Paramatti, Luca Piersanti, Davide Pinci, Antoni Rucinski, Andrea Russomando, Alessio Sarti, Adalberto Sciubba, Martina Senzacqua, Elena Solfaroli-Camillocci, Marco Toppi, Cecilia Voena, Vincenzo Patera

    Abstract: Charged Particle Therapy is a technique for cancer treatment that exploits hadron beams, mostly protons and carbons. A critical issue is the monitoring of the dose released by the beam to the tumor and to the surrounding tissues. We present the design of a new tracking device for monitoring on-line the dose in ion therapy through the detection of secondary charged particles produced by the beam in… ▽ More

    Submitted 28 July, 2016; originally announced July 2016.

    Comments: Submitted to Physica Medica

  7. arXiv:1605.08377  [pdf, other

    physics.med-ph physics.ins-det

    Secondary radiation measurements for particle therapy applications: prompt photons produced by $^{4}$He, $^{12}$C and $^{16}$O ion beams in a PMMA target

    Authors: Ilaria Mattei, Francesco Collamati, Erika De Lucia, Riccardo Faccini, Paola Maria Frallicciardi, Carlo Mancini-Terracciano, Michela Marafini, Silvia Muraro, Riccardo Paramatti, Vincenzo Patera, Luca Piersanti, Davide Pinci, Antoni Rucinski, Andrea Russomando, Alessio Sarti, Adalberto Sciubba, Elena Solfaroli Camillocci, Marco Toppi, Giacomo Traini, Cecilia Voena, Giuseppe Battistoni

    Abstract: Charged particle beams are used in Particle Therapy (PT) to treat oncological patients due to their selective dose deposition in tissues and to their high biological effect in killing cancer cells with respect to photons and electrons used in conventional radiotherapy. Nowadays, protons and carbon ions are used in PT clinical routine but, recently, the interest on the potential application of heli… ▽ More

    Submitted 19 July, 2016; v1 submitted 26 May, 2016; originally announced May 2016.

    Comments: Submitted to PMB

  8. First tests for an online treatment monitoring system with in-beam PET for proton therapy

    Authors: Aafke C. Kraan, G. Battistoni, N. Belcari, N. Camarlinghi, F. Cappucci, M. Ciocca, A. Ferrari, S. Ferretti, A. Mairani, S. Molinelli, M. Pullia, A. Retico, P. Sala, G. Sportelli, A. Del Guerra, V. Rosso

    Abstract: PET imaging is a non-invasive technique for particle range verification in proton therapy. It is based on measuring the beta+ annihilations caused by nuclear interactions of the protons in the patient. In this work we present measurements for proton range verification in phantoms, performed at the CNAO particle therapy treatment center in Pavia, Italy, with our 10 x 10 cm^2 planar PET prototype Do… ▽ More

    Submitted 26 November, 2014; originally announced November 2014.

    Comments: 11 pages, 6 figures, Proceedings for International Workshop on Radiation Imaging Detectors, 2014

  9. arXiv:1305.0442  [pdf, other

    physics.ins-det physics.med-ph

    Properties of para-terphenyl as detector for alpha, beta and gamma radiation

    Authors: M. Angelone, G. Battistoni, F. Bellini, V. Bocci, F. Collamati, E. De Lucia, R. Faccini, F. Ferroni, S. Fiore, M. Marafini, D. Materazzo, I. Mattei, S. Morganti, V. Patera, L. Piersanti, M. Pillon, L. Recchia, A. Russomando, A. Sarti, A. Sciubba, E. Solfaroli Camillocci, C. Voena

    Abstract: Organic scintillators are often chosen as radiation detectors for their fast decay time and their low Z, while inorganic ones are used when high light ields are required. In this paper we show that a para-terphenyl based detector has a blend of properties of the two categories that can be optimal for energy and position measurements of low energy charged particles. On 0.1% diphenylbutadiene doped… ▽ More

    Submitted 2 May, 2013; originally announced May 2013.

    Comments: 5 pages, 6 figures

  10. arXiv:1203.4702  [pdf, other

    physics.med-ph physics.ins-det

    Charged particle's flux measurement from PMMA irradiated by 80 MeV/u carbon ion beam

    Authors: C. Agodi, G. Battistoni, F. Bellini, G. A. P. Cirrone, F. Collamati, G. Cuttone, E. De Lucia, M. De Napoli, A. Di Domenico, R. Faccini, F. Ferroni, S. Fiore, P. Gauzzi, E. Iarocci, M. Marafini, I. Mattei, S. Muraro, A. Paoloni, V. Patera, L. Piersanti, F. Romano, A. Sarti, A. Sciubba, E. Vitale, C. Voena

    Abstract: Hadrontherapy is an emerging technique in cancer therapy that uses beams of charged particles. To meet the improved capability of hadrontherapy in matching the dose release with the cancer position, new dose monitoring techniques need to be developed and introduced into clinical use. The measurement of the fluxes of the secondary particles produced by the hadron beam is of fundamental importance i… ▽ More

    Submitted 21 March, 2012; originally announced March 2012.

    Comments: 13 pages, 9 figures

    Journal ref: Phys. Med. Biol. 57 (2012) 5667

  11. arXiv:0712.4129  [pdf, ps, other

    physics.ins-det hep-ex

    Detectors and flux instrumentation for future neutrino facilities

    Authors: T. Abe, H. Aihara, C. Andreopoulos, A. Ankowski, A. Badertscher, G. Battistoni, A. Blondel, J. Bouchez, A. Bross, A. Bueno, L. Camilleri, J. E. Campagne, A. Cazes, A. Cervera-Villanueva, G. De Lellis, F. Di Capua, M. Ellis, A. Ereditato, L. S. Esposito, C. Fukushima, E. Gschwendtner, J. J. Gomez-Cadenas, M. Iwasaki, K. Kaneyuki, Y. Karadzhov , et al. (44 additional authors not shown)

    Abstract: This report summarises the conclusions from the detector group of the International Scoping Study of a future Neutrino Factory and Super-Beam neutrino facility. The baseline detector options for each possible neutrino beam are defined as follows: 1. A very massive (Megaton) water Cherenkov detector is the baseline option for a sub-GeV Beta Beam and Super Beam facility. 2. There are a number… ▽ More

    Submitted 26 December, 2007; originally announced December 2007.

    Comments: Detector report of the International Scoping Study of a future Neutrino Factory and Super-Beam facility, 86 pages, 49 figures

    Report number: RAL-TR-2007-24

    Journal ref: JINST 4:T05001,2009

  12. arXiv:physics/0306162  [pdf

    physics.comp-ph

    The FLUKA code: present applications and future developments

    Authors: A. Fasso', A. Ferrari, S. Roesler, J. Ranft, P. R. Sala, G. Battistoni, M. Campanella, F. Cerutti, L. De Biaggi, E. Gadioli, M. V. Garzelli, F. Ballarini, A. Ottolenghi, D. Scannicchio, M. Carboni, M. Pelliccioni, R. Villari, V. Andersen, A. Empl, K. Lee, L. Pinsky, T. N. Wilson, N. Zapp

    Abstract: The main features of the FLUKA Monte Carlo code, which can deal with transport and interaction of electromagnetic and hadronic particles, are summarised. The physical models embedded in FLUKA are mentioned, as well as examples of benchmarking against experimental data. A short history of the code is provided and the following examples of applications are discussed in detail: prediction of calori… ▽ More

    Submitted 23 June, 2003; originally announced June 2003.

    Comments: talk from the 2003 Computing in High Energy and Nuclear Physics (CHEP03), La Jolla, Ca, USA, March 2003, 8 pages, pdf

  13. Performance of a large limited streamer tube cell in drift mode

    Authors: G. Battistoni, M. Caccia, R. Campagnolo, C. Meroni, E. Scapparone

    Abstract: The performance of a large (3x3 $cm^2$) streamer tube cell in drift mode is shown. The detector space resolution has been studied using cosmic muons crossing an high precision silicon telescope. The experimental results are compared with a GARFIELD simulation.

    Submitted 29 May, 2001; originally announced May 2001.

    Comments: 18 pages, 7 figures. Accepted by Nucl. Instr. and Methods A

    Journal ref: Nucl.Instrum.Meth.A479:309-315,2002