New Experimentally Observable Gamma-ray Emissions from 241Am Nuclear Decay
Authors:
Katrina E. Koehler,
Michael D. Yoho,
Matthew H. Carpenter,
Mark P. Croce,
David J. Mercer,
Chandler M. Smith,
Aidan D. Tollefson,
Duc T. Vo,
Michael A. Famiano,
Caroline D. Nesaraja,
Daniel T. Becker,
Johnathon D. Gard,
Abigail L. Wessels,
Douglas A. Bennett,
J. A. B. Mates,
Nathan J. Ortiz,
Daniel R. Schmidt,
Joel N. Ullom,
Leila R. Vale
Abstract:
With the high resolution of microcalorimeter detectors, previously unresolvable gamma-ray lines are now clearly resolvable. A careful measurement of Am-241 decay with a large array of gamma-ray microcalorimeters has revealed never before seen or predicted gamma lines at 207.72 +/- 0.02 keV and 208.21 +/- 0.01 keV. These results were made possible by new microwave-multiplexing readout to increase t…
▽ More
With the high resolution of microcalorimeter detectors, previously unresolvable gamma-ray lines are now clearly resolvable. A careful measurement of Am-241 decay with a large array of gamma-ray microcalorimeters has revealed never before seen or predicted gamma lines at 207.72 +/- 0.02 keV and 208.21 +/- 0.01 keV. These results were made possible by new microwave-multiplexing readout to increase the array size and improved analysis algorithms to eliminate spectral artifacts. We suggest nuclear levels from which these gamma-rays might originate and calculate branching ratios for these transitions from measurements of both mixed Pu-Am standards and a pure Am-241 source. These results have implications for nuclear material safeguards and accounting, particularly for microcalorimeter gamma spectrometers, which are now being adopted in nuclear safeguards analytical laboratories.
△ Less
Submitted 19 August, 2024; v1 submitted 29 March, 2021;
originally announced March 2021.
-
Measurement of Ac227 Impurity in Ac225 using Decay Energy Spectroscopy
Authors:
Aidan D. Tollefson,
Chandler M. Smith,
Matthew H. Carpenter,
Mark P. Croce,
Michael E. Fassbender,
Katrina E. Koehler,
Laura M. Lilley,
Ellen M. O'Brien,
Daniel R. Schmidt,
Benjamin W. Stein,
Joel N. Ullom,
Michael D. Yoho,
David J. Mercer
Abstract:
225Ac is a valuable medical radionuclide for targeted alpha therapy, but 227Ac is an undesirable byproduct of an accelerator-based synthesis method under investigation. Sufficient detector sensitivity is critical for quantifying the trace impurity of 227Ac, with the 227Ac/225Ac activity ratio predicted to be approximately 0.15% by end-of-bombardment (EOB). Superconducting transition edge sensor (T…
▽ More
225Ac is a valuable medical radionuclide for targeted alpha therapy, but 227Ac is an undesirable byproduct of an accelerator-based synthesis method under investigation. Sufficient detector sensitivity is critical for quantifying the trace impurity of 227Ac, with the 227Ac/225Ac activity ratio predicted to be approximately 0.15% by end-of-bombardment (EOB). Superconducting transition edge sensor (TES) microcalorimeters offer high resolution energy spectroscopy using the normal-to-superconducting phase transition to measure small change in temperature. By embedding 225Ac production samples in a gold foil thermally coupled to a TES microcalorimeter we can measure the decay energies of the radionuclides embedded with high resolution and efficiency. This technique, known as decay energy spectroscopy (DES), collapses several peaks from alpha decays into single Q-value peaks. In practice there are more complex factors in the interpretation of data using DES, which we will discuss herein. Using this technique we measured the EOB 227Ac impurity to be (0.142 +/- 0.005)% for a single production sample. This demonstration has shown that DES can distinguish closely related isotopic features and is a useful tool for quantitative measures.
△ Less
Submitted 3 February, 2021;
originally announced February 2021.
-
Improved Plutonium and Americium Photon Branching Ratios from Microcalorimeter Gamma Spectroscopy
Authors:
Michael D. Yoho,
Katrina E. Koehler,
Daniel T. Becker,
Douglas A. Bennett,
Matthew H. Carpenter,
Mark P. Croce,
Johnathon D. Gard,
J. A. Ben Mates,
David J. Mercer,
Nathan J. Ortiz,
Daniel R. Schmidt,
Chandler M. Smith,
Daniel S. Swetz,
Aidan D. Tollefson,
Joel N. Ullom,
Leila R. Vale,
Abigail L. Wessels,
Duc T. Vo
Abstract:
Photon branching ratios are critical input data for activities such as nuclear materials protection and accounting because they allow material compositions to be extracted from measurements of gamma-ray intensities. Uncertainties in these branching ratios are often a limiting source of uncertainty in composition determination. Here, we use high statistics, high resolution (~60-70eV full-width-at-h…
▽ More
Photon branching ratios are critical input data for activities such as nuclear materials protection and accounting because they allow material compositions to be extracted from measurements of gamma-ray intensities. Uncertainties in these branching ratios are often a limiting source of uncertainty in composition determination. Here, we use high statistics, high resolution (~60-70eV full-width-at-half-maximum at 100 keV) gamma-ray spectra acquired using microcalorimeter sensors to substantially reduce the uncertainties for 11 plutonium (238Pu,239Pu,241Pu) and 241Am branching ratios important for material control and accountability and nuclear forensics in the energy range of 125 keV to 208 keV. We show a reduction in uncertainty of over a factor of three for one branching ratio and a factor of 2{3 for four branching ratios.
△ Less
Submitted 22 June, 2020; v1 submitted 20 May, 2020;
originally announced May 2020.