-
Design,fabrication and characterization of 8x9 n-type silicon pad array for sampling calorimetry
Authors:
Sawan,
G. Tambave,
J. L. Bouly,
O. Bourrion,
T. Chujo,
A. Das,
M. Inaba,
V. K. S. Kashyap,
C. Krug,
R. Laha,
C. Loizides,
B. Mohanty,
M. M. Mondal N. Ponchant,
K. P. Sharma,
R. Singh,
D. Tourres
Abstract:
This paper reports the development and testing of n-type silicon pad array detectors targeted for the Forward Calorimeter (FoCal) detector, which is an upgrade of the ALICE detector at CERN, scheduled for data taking in Run~4~(2029-2034). The FoCal detector includes hadronic and electromagnetic calorimeters, with the latter made of tungsten absorber layers and granular silicon pad arrays read out…
▽ More
This paper reports the development and testing of n-type silicon pad array detectors targeted for the Forward Calorimeter (FoCal) detector, which is an upgrade of the ALICE detector at CERN, scheduled for data taking in Run~4~(2029-2034). The FoCal detector includes hadronic and electromagnetic calorimeters, with the latter made of tungsten absorber layers and granular silicon pad arrays read out using the High Granularity Calorimeter Readout Chip~(HGCROC). This paper covers the Technology Computer-Aided Design (TCAD) simulations, the fabrication process, current versus voltage (IV) and capacitance versus voltage (CV) measurements, test results with a blue LED and $^{90}$Sr beta source, and neutron radiation hardness tests. IV measurements for the detector showed that 90\% of the pads had leakage current below 10~nA at full depletion voltage. Simulations predicted a breakdown voltage of 1000~V and practical tests confirmed stable operation up to 500~V without breakdown. CV measurements in the data and the simulations gave a full depletion voltage of around 50~V at a capacitance of 35~pF. LED tests verified that all detector pads responded correctly. Additionally, the 1$\times$1 cm$^2$ pads were also tested with the neutron radiations at a fluence of $5\times10^{13}$ 1~MeV~n$_{eq}$/cm$^2$.
△ Less
Submitted 12 June, 2024;
originally announced June 2024.
-
Beam test of n-type Silicon pad array detector at PS CERN
Authors:
Sawan,
M. Bregant,
J. L. Bouly,
O. Bourrion,
A. van den Brink,
T. Chujo,
C. Krug,
L. Kumar,
V. K. S. Kashyap,
A. Ghimouz,
M. Inaba,
T. Isidori,
C. Loizides,
B. Mohanty,
M. M. Mondal,
N. Minafra,
N. Novitzky,
N. Ponchant,
M. Rauch,
K. P. Sharma,
R. Singh,
D. Thienpont,
D. Tourres,
G. Tambave
Abstract:
This work reports the testing of a Forward Calorimeter (FoCal) prototype based on an n-type Si pad array detector at the CERN PS accelerator. The FoCal is a proposed upgrade in the ALICE detector operating within the pseudorapidity range of 3.2 < $\mathrmη$ < 5.8. It aims to measure direct photons, neutral hadrons, vector mesons, and jets for the study of gluon saturation effects in the unexplored…
▽ More
This work reports the testing of a Forward Calorimeter (FoCal) prototype based on an n-type Si pad array detector at the CERN PS accelerator. The FoCal is a proposed upgrade in the ALICE detector operating within the pseudorapidity range of 3.2 < $\mathrmη$ < 5.8. It aims to measure direct photons, neutral hadrons, vector mesons, and jets for the study of gluon saturation effects in the unexplored region of low momentum fraction x ($\mathrm{\sim10^{-5} - 10^{-6}}$). The prototype is a $\mathrm{8\times9}$ n-type Si pad array detector with each pad occupying one cm$^2$ area, fabricated on a 6-in, 325~$\mathrm{\pm 10 \thinspace μ}$m thick, and high-resistivity ($\sim$7 k$Ω\thinspace$ cm) Si wafer which is readout using HGCROCv2 chip. The detector is tested using pion beams of energy 10~GeV and electron beams of energy 1-5~GeV. The measurements of the Minimum Ionizing Particle (MIP) response of pions and the shower profiles of electrons are reported.
△ Less
Submitted 20 March, 2024;
originally announced March 2024.
-
First measurement of the nuclear-recoil ionization yield in silicon at 100 eV
Authors:
M. F. Albakry,
I. Alkhatib,
D. Alonso,
D. W. P. Amaral,
P. An,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
P. S. Barbeau,
C. Bathurst,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott
, et al. (115 additional authors not shown)
Abstract:
We measured the nuclear--recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from 4\,keV down to 100\,eV, the lowest energy probed so far. The results show no sign of an ionization production threshold above 100\,eV. These results call for furthe…
▽ More
We measured the nuclear--recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from 4\,keV down to 100\,eV, the lowest energy probed so far. The results show no sign of an ionization production threshold above 100\,eV. These results call for further investigation of the ionization yield theory and a comprehensive determination of the detector response function at energies below the keV scale.
△ Less
Submitted 3 March, 2023;
originally announced March 2023.
-
Development of a large-mass, low-threshold detector system with simultaneous measurements of athermal phonons and scintillation light
Authors:
M. Chaudhuri,
G. Agnolet,
V. Iyer,
V. K. S. Kashyap,
M. Lee,
R. Mahapatra,
S. Maludze,
N. Mirabolfathi,
B. Mohanty,
M. Platt,
A. Upadhyay,
S. Sahoo,
S. Verma
Abstract:
We have combined two low-threshold detector technologies to develop a large-mass, low-threshold detector system that simultaneously measures the athermal phonons in a sapphire detector while an adjacent silicon high-voltage detector detects the scintillation light from the sapphire detector. This detector system could provide event-by-event discrimination between electron and nuclear events due to…
▽ More
We have combined two low-threshold detector technologies to develop a large-mass, low-threshold detector system that simultaneously measures the athermal phonons in a sapphire detector while an adjacent silicon high-voltage detector detects the scintillation light from the sapphire detector. This detector system could provide event-by-event discrimination between electron and nuclear events due to the difference in their scintillation light yield. While such systems with simultaneous phonon and light detection have been demonstrated earlier with smaller detectors, our system is designed to provide a large detector mass with high amplification for the limited scintillation light. Future work will focus on at least an order of magnitude improvement in the light collection efficiency by having a highly reflective detector housing and custom phonon mask design to maximize light collection by the silicon high-voltage detector.
△ Less
Submitted 8 December, 2022;
originally announced December 2022.
-
ATHENA Detector Proposal -- A Totally Hermetic Electron Nucleus Apparatus proposed for IP6 at the Electron-Ion Collider
Authors:
ATHENA Collaboration,
J. Adam,
L. Adamczyk,
N. Agrawal,
C. Aidala,
W. Akers,
M. Alekseev,
M. M. Allen,
F. Ameli,
A. Angerami,
P. Antonioli,
N. J. Apadula,
A. Aprahamian,
W. Armstrong,
M. Arratia,
J. R. Arrington,
A. Asaturyan,
E. C. Aschenauer,
K. Augsten,
S. Aune,
K. Bailey,
C. Baldanza,
M. Bansal,
F. Barbosa,
L. Barion
, et al. (415 additional authors not shown)
Abstract:
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its e…
▽ More
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its expected performance in the most relevant physics channels. It includes an evaluation of detector technology choices, the technical challenges to realizing the detector and the R&D required to meet those challenges.
△ Less
Submitted 13 October, 2022;
originally announced October 2022.
-
Large-mass, low-threshold sapphire detector for rare event searches
Authors:
S. Verma,
S. Maludze,
M. Lee,
M. Chaudhuri,
V. Iyer,
V. K. S. Kashyap,
A. Kubik,
T. Lin,
R. Mahapatra,
N. Mirabolfathi,
N. Mishra,
B. Mohanty,
H. Neog,
A. Jastram,
M. Platt Platta
Abstract:
Low mass nuclear recoil dark matter and coherent-elastic-neutrino-nucleus-scattering (CENNS) searches confront similar challenges in choosing ultra-low threshold and large-mass detectors. We report experimental results from the first-of-its-kind 100 g single-crystal sapphire detector design with a diameter of 76 mm and thickness of 4 mm. The detector is designed to be sensitive for low-energy rare…
▽ More
Low mass nuclear recoil dark matter and coherent-elastic-neutrino-nucleus-scattering (CENNS) searches confront similar challenges in choosing ultra-low threshold and large-mass detectors. We report experimental results from the first-of-its-kind 100 g single-crystal sapphire detector design with a diameter of 76 mm and thickness of 4 mm. The detector is designed to be sensitive for low-energy rare interactions with an intention to investigate the low mass region of dark matter phase-space and search for CENNS at the reactor site. Sapphire is a crystal of aluminum oxide (Al2O3) and has been found to be a good candidate for light mass spin-dependent dark matter search experiments due to its lower atomic mass compared to other detector materials such as germanium and silicon. Using the data collected from the test facility at Texas A&M University, we were able to resolve low energy lines from calibration sources and estimated that our newly developed sapphire detector has a baseline recoil energy resolution of 18 eV. These detectors are operated at 0 V with the phonon-assisted detection providing a quenching-free low-threshold operation.
△ Less
Submitted 26 March, 2022;
originally announced March 2022.
-
A Strategy for Low-Mass Dark Matter Searches with Cryogenic Detectors in the SuperCDMS SNOLAB Facility
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeno,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott,
J. Cooley
, et al. (103 additional authors not shown)
Abstract:
The SuperCDMS Collaboration is currently building SuperCDMS SNOLAB, a dark matter search focused on nucleon-coupled dark matter in the 1-5 GeV/c$^2$ mass range. Looking to the future, the Collaboration has developed a set of experience-based upgrade scenarios, as well as novel directions, to extend the search for dark matter using the SuperCDMS technology in the SNOLAB facility. The experienced-ba…
▽ More
The SuperCDMS Collaboration is currently building SuperCDMS SNOLAB, a dark matter search focused on nucleon-coupled dark matter in the 1-5 GeV/c$^2$ mass range. Looking to the future, the Collaboration has developed a set of experience-based upgrade scenarios, as well as novel directions, to extend the search for dark matter using the SuperCDMS technology in the SNOLAB facility. The experienced-based scenarios are forecasted to probe many square decades of unexplored dark matter parameter space below 5 GeV/c$^2$, covering over 6 decades in mass: 1-100 eV/c$^2$ for dark photons and axion-like particles, 1-100 MeV/c$^2$ for dark-photon-coupled light dark matter, and 0.05-5 GeV/c$^2$ for nucleon-coupled dark matter. They will reach the neutrino fog in the 0.5-5 GeV/c$^2$ mass range and test a variety of benchmark models and sharp targets. The novel directions involve greater departures from current SuperCDMS technology but promise even greater reach in the long run, and their development must begin now for them to be available in a timely fashion.
The experienced-based upgrade scenarios rely mainly on dramatic improvements in detector performance based on demonstrated scaling laws and reasonable extrapolations of current performance. Importantly, these improvements in detector performance obviate significant reductions in background levels beyond current expectations for the SuperCDMS SNOLAB experiment. Given that the dominant limiting backgrounds for SuperCDMS SNOLAB are cosmogenically created radioisotopes in the detectors, likely amenable only to isotopic purification and an underground detector life-cycle from before crystal growth to detector testing, the potential cost and time savings are enormous and the necessary improvements much easier to prototype.
△ Less
Submitted 1 April, 2023; v1 submitted 16 March, 2022;
originally announced March 2022.
-
A novel active veto prototype detector with an inner target for improved rare event searches
Authors:
M. Chaudhuri,
A. Jastram,
G. Agnolet,
S. Banik,
H. Chen,
V. Iyer,
V. K. S. Kashyap,
A. Kubik,
M. Lee,
R. Mahapatra,
S. Maludze,
N. Mirabolfathi,
N. Mishra,
B. Mohanty,
H. Neog,
M. Platt
Abstract:
We report the fabrication and performance of an annular, cryogenic, phonon-mediated veto detector that can host an inner target detector, allowing substantial reduction in radiogenic backgrounds for rare event search experiments. A germanium veto detector of mass $\sim$500 g with an outer diameter of 76 mm and an inner diameter of 28 mm was produced. A 25 mm diameter germanium inner target detecto…
▽ More
We report the fabrication and performance of an annular, cryogenic, phonon-mediated veto detector that can host an inner target detector, allowing substantial reduction in radiogenic backgrounds for rare event search experiments. A germanium veto detector of mass $\sim$500 g with an outer diameter of 76 mm and an inner diameter of 28 mm was produced. A 25 mm diameter germanium inner target detector of mass $\sim$10 g was mounted inside the veto detector. The detector was designed using inputs from a GEANT4 based simulation, where it was modeled to be sandwiched between two germanium detectors. The simulation showed that the background rates (dominantly gamma interactions) could be reduced by $>$ 90$\%$, and that such an arrangement is sufficient for aggressive background reduction needed for neutrino and dark matter search experiments. During testing at the experimental site the veto detector prototype achieved a baseline resolution of 1.24 $\pm$ 0.02 keV while hosting a functional inner target detector. The baseline resolution of the inner target detector was 147 $\pm$ 2 eV. The detectors were operated at mK temperatures. The experimental results of an identical detector arrangement are in excellent agreement with the simulation.
△ Less
Submitted 22 February, 2022;
originally announced February 2022.