Measurement and analysis of the $^{246}$Cm and $^{248}$Cm neutron capture cross-sections at the EAR2 of the n TOF facility
Authors:
V. Alcayne,
A. Kimura,
E. Mendoza,
D. Cano-Ott,
O. Aberle,
F. Álvarez-Velarde,
S. Amaducci,
J. Andrzejewski,
L. Audouin,
V. Bécares,
V. Babiano-Suarez,
M. Bacak,
M. Barbagallo,
F. Bečvář,
G. Bellia,
E. Berthoumieux,
J. Billowes,
D. Bosnar,
A. Brown,
M. Busso,
M. Caamaño,
L. Caballero-Ontanaya,
F. Calviño,
M. Calviani,
A. Casanovas
, et al. (108 additional authors not shown)
Abstract:
The $^{246}$Cm(n,$γ$) and $^{248}$Cm(n,$γ$) cross-sections have been measured at the Experimental Area 2 (EAR2) of the n_TOF facility at CERN with three C$_6$D$_6$ detectors. This measurement is part of a collective effort to improve the capture cross-section data for Minor Actinides (MAs), which are required to estimate the production and transmutation rates of these isotopes in light water react…
▽ More
The $^{246}$Cm(n,$γ$) and $^{248}$Cm(n,$γ$) cross-sections have been measured at the Experimental Area 2 (EAR2) of the n_TOF facility at CERN with three C$_6$D$_6$ detectors. This measurement is part of a collective effort to improve the capture cross-section data for Minor Actinides (MAs), which are required to estimate the production and transmutation rates of these isotopes in light water reactors and innovative reactor systems. In particular, the neutron capture in $^{246}$Cm and $^{248}$Cm open the path for the formation of other Cm isotopes and heavier elements such as Bk and Cf and the knowledge of (n,$γ$) cross-sections of these Cm isotopes plays an important role in the transport, transmutation and storage of the spent nuclear fuel. The reactions $^{246}$Cm(n,$γ$) and $^{248}$Cm(n,$γ$) have been the two first capture measurements analyzed at n_TOF EAR2. Until this experiment and two recent measurements performed at J-PARC, there was only one set of data of the capture cross-sections of $^{246}$Cm and $^{248}$Cm, that was obtained in 1969 in an underground nuclear explosion experiment. In the measurement at n_TOF a total of 13 resonances of $^{246}$Cm between 4 and 400 eV and 5 of $^{248}$Cm between 7 and 100 eV have been identified and fitted. The radiative kernels obtained for $^{246}$Cm are compatible with JENDL-5, but some of them are not with JENDL-4, which has been adopted by JEFF-3.3 and ENDF/B-VIII.0. The radiative kernels obtained for the first three $^{248}$Cm resonances are compatible with JENDL-5, however, the other two are not compatible with any other evaluation and are 20% and 60% larger than JENDL-5.
△ Less
Submitted 8 July, 2024;
originally announced July 2024.
First tests of the applicability of $γ$-ray imaging for background discrimination in time-of-flight neutron capture measurements
Authors:
D. L. Pérez Magán,
L. Caballero-Ontanaya,
C. Domingo-Pardo,
J. Agramunt-Ros,
F. Albiol,
A. Casanovas,
A. González,
C. Guerrero,
J. Lerendegui-Marco,
A. Tarifeño-Saldivia,
the n_TOF Collaboration
Abstract:
In this work we explore for the first time the applicability of using $γ$-ray imaging in neutron capture measurements to identify and suppress spatially localized background. For this aim, a pinhole gamma camera is assembled, tested and characterized in terms of energy and spatial performance. It consists of a monolithic CeBr$_3$ scintillating crystal coupled to a position-sensitive photomultiplie…
▽ More
In this work we explore for the first time the applicability of using $γ$-ray imaging in neutron capture measurements to identify and suppress spatially localized background. For this aim, a pinhole gamma camera is assembled, tested and characterized in terms of energy and spatial performance. It consists of a monolithic CeBr$_3$ scintillating crystal coupled to a position-sensitive photomultiplier and readout through an integrated circuit AMIC2GR. The pinhole collimator is a massive carven block of lead. A series of dedicated measurements with calibrated sources and with a neutron beam incident on a $^{197}$Au sample have been carried out at n_TOF, achieving an enhancement of a factor of two in the signal-to-background ratio when selecting only those events coming from the direction of the sample.
△ Less
Submitted 14 October, 2015; v1 submitted 8 October, 2015;
originally announced October 2015.