-
Characterization of electroless nickel-phosphorus plating for ultracold-neutron storage
Authors:
H. Akatsuka,
T. Andalib,
B. Bell,
J. Berean-Dutcher,
N. Bernier,
C. P. Bidinosti,
C. Cude-Woods,
S. A. Currie,
C. A. Davis,
B. Franke,
R. Gaur,
P. Giampa,
S. Hansen-Romu,
M. T. Hassan,
K. Hatanaka,
T. Higuchi,
C. Gibson,
G. Ichikawa,
I. Ide,
S. Imajo,
T. M. Ito,
B. Jamieson,
S. Kawasaki,
M. Kitaguchi,
W. Klassen
, et al. (29 additional authors not shown)
Abstract:
Electroless nickel plating is an established industrial process that provides a robust and relatively low-cost coating suitable for transporting and storing ultracold neutrons (UCN). Using roughness measurements and UCN-storage experiments we characterized UCN guides made from polished aluminum or stainless-steel tubes plated by several vendors. All electroless nickel platings were similarly suite…
▽ More
Electroless nickel plating is an established industrial process that provides a robust and relatively low-cost coating suitable for transporting and storing ultracold neutrons (UCN). Using roughness measurements and UCN-storage experiments we characterized UCN guides made from polished aluminum or stainless-steel tubes plated by several vendors. All electroless nickel platings were similarly suited for UCN storage with an average loss probability per wall bounce of $2.8\cdot10^{-4}$ to $4.1\cdot10^{-4}$ for energies between 90 neV and 190 neV, or a ratio of imaginary to real Fermi potential $η$ of $1.7\cdot10^{-4}$ to $3.3\cdot10^{-4}$. Measurements at different elevations indicate that the energy dependence of UCN losses is well described by the imaginary Fermi potential. Some special considerations are required to avoid an increase in surface roughness during the plating process and hence a reduction in UCN transmission. Increased roughness had only a minor impact on storage properties. Based on these findings we chose a vendor to plate the UCN-production vessel that will contain the superfluid-helium converter for the new TRIUMF UltraCold Advanced Neutron (TUCAN) source, achieving acceptable UCN-storage properties with ${η=3.5(5)\cdot10^{-4}}$.
△ Less
Submitted 7 February, 2023; v1 submitted 10 August, 2022;
originally announced August 2022.
-
A fast-switching magnet serving a spallation-driven ultracold neutron source
Authors:
S. Ahmed,
E. Altiere,
T. Andalib,
M. J. Barnes,
B. Bell,
C. P. Bidinosti,
Y. Bylinsky,
J. Chak,
M. Das,
C. A. Davis,
F. Fischer,
B. Franke,
M. T. W. Gericke,
P. Giampa,
M. Hahn,
S. Hansen-Romu,
K. Hatanaka,
T. Hayamizu,
B. Jamieson,
D. Jones,
K. Katsika,
S. Kawasaki,
T. Kikawa,
W. Klassen,
A. Konaka
, et al. (25 additional authors not shown)
Abstract:
A fast-switching, high-repetition-rate magnet and power supply have been developed for and operated at TRIUMF, to deliver a proton beam to the new ultracold neutron (UCN) facility. The facility possesses unique operational requirements: a time-averaged beam current of 40~$μ$A with the ability to switch the beam on or off for several minutes. These requirements are in conflict with the typical oper…
▽ More
A fast-switching, high-repetition-rate magnet and power supply have been developed for and operated at TRIUMF, to deliver a proton beam to the new ultracold neutron (UCN) facility. The facility possesses unique operational requirements: a time-averaged beam current of 40~$μ$A with the ability to switch the beam on or off for several minutes. These requirements are in conflict with the typical operation mode of the TRIUMF cyclotron which delivers nearly continuous beam to multiple users. To enable the creation of the UCN facility, a beam-sharing arrangement with another facility was made. The beam sharing is accomplished by the fast-switching (kicker) magnet which is ramped in 50~$μ$s to a current of 193~A, held there for approximately 1~ms, then ramped down in the same short period of time. This achieves a 12~mrad deflection which is sufficient to switch the proton beam between the two facilities. The kicker magnet relies on a high-current, low-inductance coil connected to a fast-switching power supply that is based on insulated-gate bipolar transistors (IGBTs). The design and performance of the kicker magnet system and initial beam delivery results are reported.
△ Less
Submitted 11 August, 2019; v1 submitted 21 May, 2019;
originally announced May 2019.
-
First ultracold neutrons produced at TRIUMF
Authors:
S. Ahmed,
E. Altiere,
T. Andalib,
B. Bell,
C. P. Bidinosti,
E. Cudmore,
M. Das,
C. A. Davis,
B. Franke,
M. Gericke,
P. Giampa,
P. Gnyp,
S. Hansen-Romu,
K. Hatanaka,
T. Hayamizu,
B. Jamieson,
D. Jones,
S. Kawasaki,
T. Kikawa,
M. Kitaguchi,
W. Klassen,
A. Konaka,
E. Korkmaz,
F. Kuchler,
M. Lang
, et al. (28 additional authors not shown)
Abstract:
We installed a source for ultracold neutrons at a new, dedicated spallation target at TRIUMF. The source was originally developed in Japan and uses a superfluid-helium converter cooled to 0.9$\,$K. During an extensive test campaign in November 2017, we extracted up to 325000 ultracold neutrons after a one-minute irradiation of the target, over three times more than previously achieved with this so…
▽ More
We installed a source for ultracold neutrons at a new, dedicated spallation target at TRIUMF. The source was originally developed in Japan and uses a superfluid-helium converter cooled to 0.9$\,$K. During an extensive test campaign in November 2017, we extracted up to 325000 ultracold neutrons after a one-minute irradiation of the target, over three times more than previously achieved with this source. The corresponding ultracold-neutron density in the whole production and guide volume is 5.3$\,$cm$^{-3}$. The storage lifetime of ultracold neutrons in the source was initially 37$\,$s and dropped to 24$\,$s during the eighteen days of operation. During continuous irradiation of the spallation target, we were able to detect a sustained ultracold-neutron rate of up to 1500$\,$s$^{-1}$. Simulations of UCN production, UCN transport, temperature-dependent UCN yield, and temperature-dependent storage lifetime show excellent agreement with the experimental data and confirm that the ultracold-neutron-upscattering rate in superfluid helium is proportional to $T^7$.
△ Less
Submitted 16 December, 2018; v1 submitted 10 September, 2018;
originally announced September 2018.