-
Testing CPT symmetry in ortho-positronium decays with positronium annihilation tomography
Authors:
Paweł Moskal,
Aleksander Gajos,
Muhsin Mohammed,
Jyoti Chhokar,
Neha Chug,
Catalina Curceanu,
Eryk Czerwiński,
Meysam Dadgar,
Kamil Dulski,
Marek Gorgol,
Jacek Goworek,
Beatrix Hiesmayr,
Bożena Jasińska,
Krzysztof Kacprzak,
Łukasz Kapłon,
Hanieh Karimi,
Daria Kisielewska,
Konrad Klimaszewski,
Grzegorz Korcyl,
Paweł Kowalski,
Nikodem Krawczyk,
Wojciech Krzemień,
Tomasz Kozik,
Ewelina Kubicz,
Szymon Niedźwiecki
, et al. (13 additional authors not shown)
Abstract:
Charged lepton system symmetry under combined charge, parity, and time-reversal transformation (CPT) remains scarcely tested. Despite stringent quantum-electrodynamic limits, discrepancies in predictions for the electron-positron bound state (positronium atom) motivate further investigation, including fundamental symmetry tests. While CPT noninvariance effects could be manifested in non-vanishing…
▽ More
Charged lepton system symmetry under combined charge, parity, and time-reversal transformation (CPT) remains scarcely tested. Despite stringent quantum-electrodynamic limits, discrepancies in predictions for the electron-positron bound state (positronium atom) motivate further investigation, including fundamental symmetry tests. While CPT noninvariance effects could be manifested in non-vanishing angular correlations between final-state photons and spin of annihilating positronium, measurements were previously limited by knowledge of the latter. Here, we demonstrate tomographic reconstruction techniques applied to three-photon annihilations of ortho-positronium atoms to estimate their spin polarisation without magnetic field or polarised positronium source. We use a plastic-scintillator-based positron-emission-tomography scanner to record ortho-positronium (o-Ps) annihilations with single-event estimation of o-Ps spin and determine the complete spectrum of an angular correlation operator sensitive to CPT-violating effects. We find no violation at the precision level of 10^{-4}, with an over threefold improvement on the previous measurement.
△ Less
Submitted 8 December, 2021;
originally announced December 2021.
-
A feasibility study of the time reversal violation test based on polarization of annihilation photons from the decay of ortho-Positronium with the J-PET detector
Authors:
J. Raj,
A. Gajos,
C. Curceanu,
E. Czerwinski,
K. Dulski,
M. Gorgol,
N. Gupta-Sharma,
B. C. Hiesmayr,
B. Jasińska,
K. Kacprzak,
L. Kaplon,
D. Kisielewska,
K. Klimaszewski,
G. Korcyl,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemien,
E. Kubicz,
M. Mohammed,
Sz. Niedzwiecki,
M. Palka,
M. Pawlik-Niedzwiecka,
L. Raczynski,
K. Rakoczy
, et al. (9 additional authors not shown)
Abstract:
The Jagiellonian Positron Emission Tomograph (J-PET) is a novel de- vice being developed at Jagiellonian University in Krakow, Poland based on or- ganic scintillators. J-PET is an axially symmetric and high acceptance scanner that can be used as a multi-purpose detector system. It is well suited to pur- sue tests of discrete symmetries in decays of positronium in addition to medical imaging. J-PET…
▽ More
The Jagiellonian Positron Emission Tomograph (J-PET) is a novel de- vice being developed at Jagiellonian University in Krakow, Poland based on or- ganic scintillators. J-PET is an axially symmetric and high acceptance scanner that can be used as a multi-purpose detector system. It is well suited to pur- sue tests of discrete symmetries in decays of positronium in addition to medical imaging. J-PET enables the measurement of both momenta and the polarization vectors of annihilation photons. The latter is a unique feature of the J-PET detector which allows the study of time reversal symmetry violation operator which can be constructed solely from the annihilation photons momenta before and after the scattering in the detector.
△ Less
Submitted 4 September, 2018;
originally announced September 2018.
-
Feasibility study of the time reversal symmetry tests in decays of metastable positronium atoms with the J-PET detector
Authors:
A. Gajos,
C. Curceanu,
E. Czerwiński,
K. Dulski,
M. Gorgol,
N. Gupta-Sharma,
B. C. Hiesmayr,
B. Jasińska,
K. Kacprzak,
Ł. Kapłon,
D. Kisielewska,
G. Korcyl,
P. Kowalski,
T. Kozik,
W. Krzemień,
E. Kubicz,
M. Mohammed,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik-Niedźwiecka,
L. Raczyński,
J. Raj,
Z. Rudy,
S. Sharma,
Shivani
, et al. (7 additional authors not shown)
Abstract:
This article reports on the feasibility of testing of the symmetry under reversal in time in a purely leptonic system constituted by positronium atoms using the J-PET detector. The present state of T symmetry tests is discussed with an emphasis on the scarcely explored sector of leptonic systems. Two possible strategies of searching for manifestations of T violation in non-vanishing angular correl…
▽ More
This article reports on the feasibility of testing of the symmetry under reversal in time in a purely leptonic system constituted by positronium atoms using the J-PET detector. The present state of T symmetry tests is discussed with an emphasis on the scarcely explored sector of leptonic systems. Two possible strategies of searching for manifestations of T violation in non-vanishing angular correlations of final state observables in the decays of metastable triplet states of positronium available with J-PET are proposed and discussed. Results of a pilot measurement with J-PET and assessment of its performance in reconstruction of three-photon decays are shown along with an analysis of its impact on the sensitivity of the detector for the determination of T -violation sensitive observables.
△ Less
Submitted 19 April, 2018;
originally announced April 2018.
-
J-PET: a new technology for the whole-body PET imaging
Authors:
S. Niedźwiecki,
P. Białas,
C. Curceanu,
E. Czerwiński,
K. Dulski,
A. Gajos,
B. Głowacz,
M. Gorgol,
B. C. Hiesmayr,
B. Jasińska,
Ł. Kapłon,
D. Kisielewska-Kamińska,
G. Korcyl,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemień,
E. Kubicz,
M. Mohammed,
M. Pawlik-Niedźwiecka,
M. Pałka,
L. Raczyński,
Z. Rudy,
N. G. Sharma,
S. Sharma
, et al. (8 additional authors not shown)
Abstract:
The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET built from plastic scintillators. J-PET prototype consists of 192 detection modules arranged axially in three layers forming a cylindrical diagnostic chamber with the inner diameter of 85 cm and the axial field-of-view of 50 cm. An axial arrangement of long strips of plastic scintillators, their small light attenuation, superior…
▽ More
The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET built from plastic scintillators. J-PET prototype consists of 192 detection modules arranged axially in three layers forming a cylindrical diagnostic chamber with the inner diameter of 85 cm and the axial field-of-view of 50 cm. An axial arrangement of long strips of plastic scintillators, their small light attenuation, superior timing properties, and relative ease of the increase of the axial field-of-view opens promising perspectives for the cost effective construction of the whole-body PET scanner, as well as construction of MR and CT compatible PET inserts. Present status of the development of the J-PET tomograph will be presented and discussed.
△ Less
Submitted 31 October, 2017;
originally announced October 2017.
-
Commissioning of the J-PET detector for studies of decays of positronium atoms
Authors:
E. Czerwiński,
K. Dulski,
P. Białas,
C. Curceanu,
A. Gajos,
B. Głowacz,
M. Gorgol,
B. C. Hiesmayr,
B. Jasińska,
D. Kisielewska,
G. Korcyl,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemień,
E. Kubicz,
M. Mohammed,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik-Niedźwiecka,
L. Raczyński,
Z. Rudy,
N. G. Sharma,
S. Sharma,
R. Y. Shopa
, et al. (7 additional authors not shown)
Abstract:
The Jagiellonian Positron Emission Tomograph (J-PET) is a detector for medical imaging of the whole human body as well as for physics studies involving detection of electron-positron annihilation into photons. J-PET has high angular and time resolution and allows for measurement of spin of the positronium and the momenta and polarization vectors of annihilation quanta. In this article, we present…
▽ More
The Jagiellonian Positron Emission Tomograph (J-PET) is a detector for medical imaging of the whole human body as well as for physics studies involving detection of electron-positron annihilation into photons. J-PET has high angular and time resolution and allows for measurement of spin of the positronium and the momenta and polarization vectors of annihilation quanta. In this article, we present the potential of the J-PET system for background rejection in the decays of positronium atoms.
△ Less
Submitted 13 November, 2017; v1 submitted 30 October, 2017;
originally announced October 2017.
-
Three-dimensional image reconstruction in J-PET using Filtered Back Projection method
Authors:
R. Y. Shopa,
K. Klimaszewski,
P. Kowalski,
W. Krzemień,
L. Raczyński,
W. Wiślicki,
P. Białas,
C. Curceanu,
E. Czerwiński,
K. Dulski,
A. Gajos,
B. Głowacz,
M. Gorgol,
B. Hiesmayr,
B. Jasińska,
D. Kisielewska-Kamińska,
G. Korcyl,
T. Kozik,
N. Krawczyk,
E. Kubicz,
M. Mohammed,
M. Pawlik-Niedźwiecka,
S. Niedźwiecki,
M. Pałka,
Z. Rudy
, et al. (8 additional authors not shown)
Abstract:
We present a method and preliminary results of the image reconstruction in the Jagiellonian PET tomograph. Using GATE (Geant4 Application for Tomographic Emission), interactions of the 511 keV photons with a cylindrical detector were generated. Pairs of such photons, flying back-to-back, originate from e+e- annihilations inside a 1-mm spherical source. Spatial and temporal coordinates of hits were…
▽ More
We present a method and preliminary results of the image reconstruction in the Jagiellonian PET tomograph. Using GATE (Geant4 Application for Tomographic Emission), interactions of the 511 keV photons with a cylindrical detector were generated. Pairs of such photons, flying back-to-back, originate from e+e- annihilations inside a 1-mm spherical source. Spatial and temporal coordinates of hits were smeared using experimental resolutions of the detector. We incorporated the algorithm of the 3D Filtered Back Projection, implemented in the STIR and TomoPy software packages, which differ in approximation methods. Consistent results for the Point Spread Functions of ~5/7,mm and ~9/20, mm were obtained, using STIR, for transverse and longitudinal directions, respectively, with no time of flight information included.
△ Less
Submitted 30 October, 2017;
originally announced October 2017.
-
Multichannel FPGA based MVT system for high precision time (20~ps~RMS) and charge measurement
Authors:
M. Pałka,
P. Strzempek,
G. Korcyl,
T. Bednarski,
Sz. Niedźwiecki,
P. Białas,
E. Czerwiński,
K. Dulski,
A. Gajos,
B. Głowacz,
M. Gorgol,
B. Jasińska,
D. Kamińska,
M. Kajetanowicz,
P. Kowalski,
T. Kozik,
W. Krzemień,
E. Kubicz,
M. Mohhamed,
L. Raczyński,
Z. Rudy,
O. Rundel,
P. Salabura,
N. G. Sharma,
M. Silarski
, et al. (7 additional authors not shown)
Abstract:
In this article it is presented an FPGA based $M$ulti-$V$oltage $T$hreshold (MVT) system which allows of sampling fast signals ($1-2$ ns rising and falling edge) in both voltage and time domain. It is possible to achieve a precision of time measurement of $20$ ps RMS and reconstruct charge of signals, using a simple approach, with deviation from real value smaller than 10$\%$. Utilization of the d…
▽ More
In this article it is presented an FPGA based $M$ulti-$V$oltage $T$hreshold (MVT) system which allows of sampling fast signals ($1-2$ ns rising and falling edge) in both voltage and time domain. It is possible to achieve a precision of time measurement of $20$ ps RMS and reconstruct charge of signals, using a simple approach, with deviation from real value smaller than 10$\%$. Utilization of the differential inputs of an FPGA chip as comparators together with an implementation of a TDC inside an FPGA allowed us to achieve a compact multi-channel system characterized by low power consumption and low production costs. This paper describes realization and functioning of the system comprising 192-channel TDC board and a four mezzanine cards which split incoming signals and discriminate them. The boards have been used to validate a newly developed Time-of-Flight Positron Emission Tomography system based on plastic scintillators. The achieved full system time resolution of $σ$(TOF) $\approx 68$ ps is by factor of two better with respect to the current TOF-PET systems.
△ Less
Submitted 12 July, 2017;
originally announced July 2017.
-
Searches for discrete symmetries violation in ortho-positronium decay using the J-PET detector
Authors:
D. Kamińska,
T. Bednarski,
P. Białas,
E. Czerwiński,
A. Gajos,
M. Gorgol,
B. Jasińska,
Ł. Kapłon,
G. Korcyl,
P. Kowalski,
T. Kozik,
W. Krzemień,
E. Kubicz,
Sz. Niedźwiecki,
M. Pałka,
L. Raczyński,
Z. Rudy,
O. Rundel,
N. G. Sharma,
M. Silarski,
A. Słomski,
A. Strzelecki,
A. Wieczorek,
W. Wiślicki,
M. Zieliński
, et al. (2 additional authors not shown)
Abstract:
In this paper we present prospects for using the J-PET detector to search for discrete symmetries violations in a purely leptonic system of the positronium atom. We discuss tests of CP and CPT symmetries by means of ortho-positronium decays into three photons. No zero expectation values for chosen correlations between ortho-positronium spin and momentum vectors of photons would imply the existence…
▽ More
In this paper we present prospects for using the J-PET detector to search for discrete symmetries violations in a purely leptonic system of the positronium atom. We discuss tests of CP and CPT symmetries by means of ortho-positronium decays into three photons. No zero expectation values for chosen correlations between ortho-positronium spin and momentum vectors of photons would imply the existence of physics phenomena beyond the Standard Model. Previous measurements resulted in violation amplitude parameters for CP and CPT symmetries consistent with zero, with an uncertainty of about 10-3. The J-PET detector allows to determine those values with better precision thanks to a unique time and angular esolution combined with a high geometrical acceptance. Achieving the aforementioned is possible due to application of polymer scintillators instead of crystals as detectors of annihilation quanta.
△ Less
Submitted 3 September, 2015;
originally announced September 2015.
-
Application of the Compress Sensing Theory for Improvement of the TOF Resolution in a Novel J-PET Instrument
Authors:
L. Raczynski,
P. Moskal,
P. Kowalski,
W. Wislicki,
T. Bednarski,
P. Bialas,
E. Czerwinski,
A. Gajos,
L. Kaplon,
A. Kochanowski,
G. Korcyl,
J. Kowal,
T. Kozik,
W. Krzemien,
E. Kubicz,
Sz. Niedzwiecki,
M. Palka,
Z. Rudy,
P. Salabura,
N. G. Sharma,
M. Silarski,
A. Slomski,
J. Smyrski,
A. Strzelecki,
A. Wieczorek
, et al. (2 additional authors not shown)
Abstract:
Nowadays, in Positron Emission Tomography (PET) systems, a Time of Flight information is used to improve the image reconstruction process. In Time of Flight PET (TOF-PET), fast detectors are able to measure the difference in the arrival time of the two gamma rays, with the precision enabling to shorten significantly a range along the line-of-response (LOR) where the annihilation occurred. In the n…
▽ More
Nowadays, in Positron Emission Tomography (PET) systems, a Time of Flight information is used to improve the image reconstruction process. In Time of Flight PET (TOF-PET), fast detectors are able to measure the difference in the arrival time of the two gamma rays, with the precision enabling to shorten significantly a range along the line-of-response (LOR) where the annihilation occurred. In the new concept, called J-PET scanner, gamma rays are detected in plastic scintillators. In a single strip of J-PET system, time values are obtained by probing signals in the amplitude domain. Owing to Compress Sensing theory, information about the shape and amplitude of the signals is recovered. In this paper we demonstrate that based on the acquired signals parameters, a better signal normalization may be provided in order to improve the TOF resolution. The procedure was tested using large sample of data registered by a dedicated detection setup enabling sampling of signals with 50 ps intervals. Experimental setup provided irradiation of a chosen position in the plastic scintillator strip with annihilation gamma quanta.
△ Less
Submitted 8 August, 2015; v1 submitted 14 July, 2015;
originally announced July 2015.
-
Novel method for hit-position reconstruction using voltage signals in plastic scintillators and its application to Positron Emission Tomography
Authors:
L. Raczynski,
P. Moskal,
P. Kowalski,
W. Wislicki,
T. Bednarski,
P. Bialas,
E. Czerwinski,
L . Kaplon,
A. Kochanowski,
G. Korcyl,
J. Kowal,
T. Kozik,
W. Krzemien,
E. Kubicz,
M. Molenda,
I. Moskal,
Sz. Niedzwiecki,
M. Palka,
M. Pawlik-Niedzwiecka,
Z. Rudy,
P. Salabura,
N. G. Sharma,
M. Silarski,
A. Slomski,
J. Smyrski
, et al. (4 additional authors not shown)
Abstract:
Currently inorganic scintillator detectors are used in all commercial Time of Flight Positron Emission Tomograph (TOF-PET) devices. The J-PET collaboration investigates a possibility of construction of a PET scanner from plastic scintillators which would allow for single bed imaging of the whole human body. This paper describes a novel method of hit-position reconstruction based on sampled signals…
▽ More
Currently inorganic scintillator detectors are used in all commercial Time of Flight Positron Emission Tomograph (TOF-PET) devices. The J-PET collaboration investigates a possibility of construction of a PET scanner from plastic scintillators which would allow for single bed imaging of the whole human body. This paper describes a novel method of hit-position reconstruction based on sampled signals and an example of an application of the method for a single module with a 30 cm long plastic strip, read out on both ends by Hamamatsu R4998 photomultipliers. The sampling scheme to generate a vector with samples of a PET event waveform with respect to four user-defined amplitudes is introduced. The experimental setup provides irradiation of a chosen position in the plastic scintillator strip with an annihilation gamma quanta of energy 511~keV. The statistical test for a multivariate normal (MVN) distribution of measured vectors at a given position is developed, and it is shown that signals sampled at four thresholds in a voltage domain are approximately normally distributed variables. With the presented method of a vector analysis made out of waveform samples acquired with four thresholds, we obtain a spatial resolution of about 1 cm and a timing resolution of about 80 ps
△ Less
Submitted 31 July, 2014;
originally announced July 2014.
-
Test of a single module of the J-PET scanner based on plastic scintillators
Authors:
P. Moskal,
Sz. Niedźwiecki,
T. Bednarski,
E. Czerwiński,
Ł. Kapłon,
E. Kubicz,
I. Moskal,
M. Pawlik-Niedźwiecka,
N. G. Sharma,
M. Silarski,
M. Zieliński,
N. Zoń,
P. Białas,
A. Gajos,
A. Kochanowski,
G. Korcyl,
J. Kowal,
P. Kowalski,
T. Kozik,
W. Krzemień,
M. Molenda,
M. Pałka,
L. Raczyński,
Z. Rudy,
P. Salabura
, et al. (5 additional authors not shown)
Abstract:
Time of Flight Positron Emission Tomography scanner based on plastic scintillators is being developed at the Jagiellonian University by the J-PET collaboration. The main challenge of the conducted research lies in the elaboration of a method allowing application of plastic scintillators for the detection of low energy gamma quanta. In this article we report on tests of a single detection module bu…
▽ More
Time of Flight Positron Emission Tomography scanner based on plastic scintillators is being developed at the Jagiellonian University by the J-PET collaboration. The main challenge of the conducted research lies in the elaboration of a method allowing application of plastic scintillators for the detection of low energy gamma quanta. In this article we report on tests of a single detection module built out from BC-420 plastic scintillator strip (with dimensions of 5x19x300mm^3) read out at two ends by Hamamatsu R5320 photomultipliers. The measurements were performed using collimated beam of annihilation quanta from the 68Ge isotope and applying the Serial Data Analyzer (Lecroy SDA6000A) which enabled sampling of signals with 50ps intervals. The time resolution of the prototype module was established to be better than 80ps (sigma) for a single level discrimination. The spatial resolution of the determination of the hit position along the strip was determined to be about 0.93cm (sigma) for the annihilation quanta. The fractional energy resolution for the energy E deposited by the annihilation quanta via the Compton scattering amounts to sigma(E)/E = 0.044/sqrt(E[MeV]) and corresponds to the sigma(E)/E of 7.5% at the Compton edge.
△ Less
Submitted 29 August, 2014; v1 submitted 28 July, 2014;
originally announced July 2014.
-
Application of WLS strips for position determination in Strip PET tomograph based on plastic scintillators
Authors:
J. Smyrski,
P. Moskal,
T. Bednarski,
P. Białas,
E. Czerwiński,
Ł. Kapłon,
A. Kochanowski,
G. Korcyl,
J. Kowal,
P. Kowalski,
T. Kozik,
W. Krzemień,
M. Molenda,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik,
L. Raczyński,
Z. Rudy,
P. Salabura,
N. G. Sharma,
M. Silarski,
A. Słomski,
A. Strzelecki,
W. Wiślicki,
M. Zieliński
, et al. (1 additional authors not shown)
Abstract:
A method of determination of a gamma quantum absorption point in a plastic scintillator block using a matrix of wavelength-shifting (WLS) strips is proposed. Application of this method for improvement of position resolution in newly proposed PET detectors based on plastic scintillators is presented. The method enables to reduce parallax errors in reconstruction of images which occurs in the presen…
▽ More
A method of determination of a gamma quantum absorption point in a plastic scintillator block using a matrix of wavelength-shifting (WLS) strips is proposed. Application of this method for improvement of position resolution in newly proposed PET detectors based on plastic scintillators is presented. The method enables to reduce parallax errors in reconstruction of images which occurs in the presently used Positron Emission Tomography scanners.
△ Less
Submitted 24 November, 2013;
originally announced November 2013.
-
A novel method based solely on FPGA units enabling measurement of time and charge of analog signals in Positron Emission Tomography
Authors:
M. Pałka,
T. Bednarski,
P. Białas,
E. Czerwiński,
Ł. Kapłon,
A. Kochanowski,
G. Korcyl,
J. Kowal,
P. Kowalski,
T. Kozik,
W. Krzemień,
M. Molenda,
P. Moskal,
Sz. Niedźwiecki,
M. Pawlik,
L. Raczyński,
Z. Rudy,
P. Salabura,
N. G. Sharma,
M. Silarski,
A. Słomski,
J. Smyrski,
A. Strzelecki,
W. Wiślicki,
M. Zieliński
, et al. (1 additional authors not shown)
Abstract:
This article presents a novel technique for precise measurement of time and charge based solely on FPGA (Field Programmable Gate Array) device and few satellite discrete electronic components used in Positron Emission Tomography (PET). Described approach simplifies electronic circuits, reduces the power consumption, lowers costs, merges front-end electronics with digital electronics and also makes…
▽ More
This article presents a novel technique for precise measurement of time and charge based solely on FPGA (Field Programmable Gate Array) device and few satellite discrete electronic components used in Positron Emission Tomography (PET). Described approach simplifies electronic circuits, reduces the power consumption, lowers costs, merges front-end electronics with digital electronics and also makes more compact final design. Furthermore, it allows to measure time when analog signals cross a reference voltage at different threshold levels with a very high precision of $\sim$ 10ps (rms) and thus enables sampling of signals in a voltage domain.
△ Less
Submitted 24 November, 2013;
originally announced November 2013.