Skip to main content

Showing 1–8 of 8 results for author: Pawlik-Niedzwiecka, M

Searching in archive hep-ex. Search in all archives.
.
  1. Testing CPT symmetry in ortho-positronium decays with positronium annihilation tomography

    Authors: Paweł Moskal, Aleksander Gajos, Muhsin Mohammed, Jyoti Chhokar, Neha Chug, Catalina Curceanu, Eryk Czerwiński, Meysam Dadgar, Kamil Dulski, Marek Gorgol, Jacek Goworek, Beatrix Hiesmayr, Bożena Jasińska, Krzysztof Kacprzak, Łukasz Kapłon, Hanieh Karimi, Daria Kisielewska, Konrad Klimaszewski, Grzegorz Korcyl, Paweł Kowalski, Nikodem Krawczyk, Wojciech Krzemień, Tomasz Kozik, Ewelina Kubicz, Szymon Niedźwiecki , et al. (13 additional authors not shown)

    Abstract: Charged lepton system symmetry under combined charge, parity, and time-reversal transformation (CPT) remains scarcely tested. Despite stringent quantum-electrodynamic limits, discrepancies in predictions for the electron-positron bound state (positronium atom) motivate further investigation, including fundamental symmetry tests. While CPT noninvariance effects could be manifested in non-vanishing… ▽ More

    Submitted 8 December, 2021; originally announced December 2021.

    Comments: This is a preprint of an article published in Nature Communications. The final version is available at https://rdcu.be/cCQqq

    Journal ref: Nature Communications 12, 5658 (2021)

  2. arXiv:1809.00847  [pdf, other

    physics.ins-det hep-ex

    A feasibility study of the time reversal violation test based on polarization of annihilation photons from the decay of ortho-Positronium with the J-PET detector

    Authors: J. Raj, A. Gajos, C. Curceanu, E. Czerwinski, K. Dulski, M. Gorgol, N. Gupta-Sharma, B. C. Hiesmayr, B. Jasińska, K. Kacprzak, L. Kaplon, D. Kisielewska, K. Klimaszewski, G. Korcyl, P. Kowalski, T. Kozik, N. Krawczyk, W. Krzemien, E. Kubicz, M. Mohammed, Sz. Niedzwiecki, M. Palka, M. Pawlik-Niedzwiecka, L. Raczynski, K. Rakoczy , et al. (9 additional authors not shown)

    Abstract: The Jagiellonian Positron Emission Tomograph (J-PET) is a novel de- vice being developed at Jagiellonian University in Krakow, Poland based on or- ganic scintillators. J-PET is an axially symmetric and high acceptance scanner that can be used as a multi-purpose detector system. It is well suited to pur- sue tests of discrete symmetries in decays of positronium in addition to medical imaging. J-PET… ▽ More

    Submitted 4 September, 2018; originally announced September 2018.

  3. arXiv:1804.07148  [pdf, other

    physics.ins-det hep-ex

    Feasibility study of the time reversal symmetry tests in decays of metastable positronium atoms with the J-PET detector

    Authors: A. Gajos, C. Curceanu, E. Czerwiński, K. Dulski, M. Gorgol, N. Gupta-Sharma, B. C. Hiesmayr, B. Jasińska, K. Kacprzak, Ł. Kapłon, D. Kisielewska, G. Korcyl, P. Kowalski, T. Kozik, W. Krzemień, E. Kubicz, M. Mohammed, Sz. Niedźwiecki, M. Pałka, M. Pawlik-Niedźwiecka, L. Raczyński, J. Raj, Z. Rudy, S. Sharma, Shivani , et al. (7 additional authors not shown)

    Abstract: This article reports on the feasibility of testing of the symmetry under reversal in time in a purely leptonic system constituted by positronium atoms using the J-PET detector. The present state of T symmetry tests is discussed with an emphasis on the scarcely explored sector of leptonic systems. Two possible strategies of searching for manifestations of T violation in non-vanishing angular correl… ▽ More

    Submitted 19 April, 2018; originally announced April 2018.

    Comments: 15 pages, 9 figures. Submitted to Advances in High Energy Physics

  4. arXiv:1710.11369  [pdf, other

    physics.ins-det hep-ex physics.med-ph

    J-PET: a new technology for the whole-body PET imaging

    Authors: S. Niedźwiecki, P. Białas, C. Curceanu, E. Czerwiński, K. Dulski, A. Gajos, B. Głowacz, M. Gorgol, B. C. Hiesmayr, B. Jasińska, Ł. Kapłon, D. Kisielewska-Kamińska, G. Korcyl, P. Kowalski, T. Kozik, N. Krawczyk, W. Krzemień, E. Kubicz, M. Mohammed, M. Pawlik-Niedźwiecka, M. Pałka, L. Raczyński, Z. Rudy, N. G. Sharma, S. Sharma , et al. (8 additional authors not shown)

    Abstract: The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET built from plastic scintillators. J-PET prototype consists of 192 detection modules arranged axially in three layers forming a cylindrical diagnostic chamber with the inner diameter of 85 cm and the axial field-of-view of 50 cm. An axial arrangement of long strips of plastic scintillators, their small light attenuation, superior… ▽ More

    Submitted 31 October, 2017; originally announced October 2017.

    Comments: Presented at the 2nd Jagiellonian Symposium on Fundamental and Applied Subatomic Physics, Kraków, Poland, June 4-9, 2017. To be published in Acta Phys. Pol. B

    Journal ref: Acta Physica Polonica B, Vol. 48, pp. 1567, 2017

  5. arXiv:1710.11067  [pdf, other

    physics.ins-det hep-ex physics.med-ph

    Commissioning of the J-PET detector for studies of decays of positronium atoms

    Authors: E. Czerwiński, K. Dulski, P. Białas, C. Curceanu, A. Gajos, B. Głowacz, M. Gorgol, B. C. Hiesmayr, B. Jasińska, D. Kisielewska, G. Korcyl, P. Kowalski, T. Kozik, N. Krawczyk, W. Krzemień, E. Kubicz, M. Mohammed, Sz. Niedźwiecki, M. Pałka, M. Pawlik-Niedźwiecka, L. Raczyński, Z. Rudy, N. G. Sharma, S. Sharma, R. Y. Shopa , et al. (7 additional authors not shown)

    Abstract: The Jagiellonian Positron Emission Tomograph (J-PET) is a detector for medical imaging of the whole human body as well as for physics studies involving detection of electron-positron annihilation into photons. J-PET has high angular and time resolution and allows for measurement of spin of the positronium and the momenta and polarization vectors of annihilation quanta. In this article, we present… ▽ More

    Submitted 13 November, 2017; v1 submitted 30 October, 2017; originally announced October 2017.

    Comments: Presented at the 2nd Jagiellonian Symposium on Fundamental and Applied Subatomic Physics, Kraków, Poland, June 4-9, 2017. To be published in Acta Phys. Pol. B

  6. arXiv:1710.11058  [pdf, other

    physics.ins-det hep-ex physics.med-ph

    Three-dimensional image reconstruction in J-PET using Filtered Back Projection method

    Authors: R. Y. Shopa, K. Klimaszewski, P. Kowalski, W. Krzemień, L. Raczyński, W. Wiślicki, P. Białas, C. Curceanu, E. Czerwiński, K. Dulski, A. Gajos, B. Głowacz, M. Gorgol, B. Hiesmayr, B. Jasińska, D. Kisielewska-Kamińska, G. Korcyl, T. Kozik, N. Krawczyk, E. Kubicz, M. Mohammed, M. Pawlik-Niedźwiecka, S. Niedźwiecki, M. Pałka, Z. Rudy , et al. (8 additional authors not shown)

    Abstract: We present a method and preliminary results of the image reconstruction in the Jagiellonian PET tomograph. Using GATE (Geant4 Application for Tomographic Emission), interactions of the 511 keV photons with a cylindrical detector were generated. Pairs of such photons, flying back-to-back, originate from e+e- annihilations inside a 1-mm spherical source. Spatial and temporal coordinates of hits were… ▽ More

    Submitted 30 October, 2017; originally announced October 2017.

    Comments: Presented at the 2nd Jagiellonian Symposium on Fundamental and Applied Subatomic Physics, Kraków, Poland, June 4-9, 2017. To be published in Acta Phys. Pol. B

    Journal ref: Acta Physica Polonica B, Vol. 48, pp. 1757, 2017

  7. arXiv:1407.8293  [pdf, other

    physics.ins-det hep-ex

    Novel method for hit-position reconstruction using voltage signals in plastic scintillators and its application to Positron Emission Tomography

    Authors: L. Raczynski, P. Moskal, P. Kowalski, W. Wislicki, T. Bednarski, P. Bialas, E. Czerwinski, L . Kaplon, A. Kochanowski, G. Korcyl, J. Kowal, T. Kozik, W. Krzemien, E. Kubicz, M. Molenda, I. Moskal, Sz. Niedzwiecki, M. Palka, M. Pawlik-Niedzwiecka, Z. Rudy, P. Salabura, N. G. Sharma, M. Silarski, A. Slomski, J. Smyrski , et al. (4 additional authors not shown)

    Abstract: Currently inorganic scintillator detectors are used in all commercial Time of Flight Positron Emission Tomograph (TOF-PET) devices. The J-PET collaboration investigates a possibility of construction of a PET scanner from plastic scintillators which would allow for single bed imaging of the whole human body. This paper describes a novel method of hit-position reconstruction based on sampled signals… ▽ More

    Submitted 31 July, 2014; originally announced July 2014.

  8. arXiv:1407.7395  [pdf, ps, other

    physics.ins-det hep-ex nucl-ex physics.med-ph

    Test of a single module of the J-PET scanner based on plastic scintillators

    Authors: P. Moskal, Sz. Niedźwiecki, T. Bednarski, E. Czerwiński, Ł. Kapłon, E. Kubicz, I. Moskal, M. Pawlik-Niedźwiecka, N. G. Sharma, M. Silarski, M. Zieliński, N. Zoń, P. Białas, A. Gajos, A. Kochanowski, G. Korcyl, J. Kowal, P. Kowalski, T. Kozik, W. Krzemień, M. Molenda, M. Pałka, L. Raczyński, Z. Rudy, P. Salabura , et al. (5 additional authors not shown)

    Abstract: Time of Flight Positron Emission Tomography scanner based on plastic scintillators is being developed at the Jagiellonian University by the J-PET collaboration. The main challenge of the conducted research lies in the elaboration of a method allowing application of plastic scintillators for the detection of low energy gamma quanta. In this article we report on tests of a single detection module bu… ▽ More

    Submitted 29 August, 2014; v1 submitted 28 July, 2014; originally announced July 2014.

    Comments: 12 pages, 6 figures; Updated with editorial corrections related to publication in NIM A

    Journal ref: Nuclear Inst. and Methods in Physics Research A 764 (2014), pp. 317-321