Characterisation of Gamma-irradiated MCz-Silicon Detectors with a High-$K$ Negative Oxide as Field Insulator
Authors:
S. Bharthuar,
M. Bezak,
E. Brücken,
A Gädda,
M. Golovleva,
A. Karadzhinova-Ferrer,
A. Karjalainen,
N. Kramarenko,
S. Kirschenmann,
P. Luukka,
J. Ott,
E. Tuominen,
M. Väänänen
Abstract:
The high-luminosity operation of the Tracker in the Compact Muon Solenid (CMS) detector at the Large Hadron Collider (LHC) experiment calls for the development of silicon-based sensors. This involves implementation of AC-coupling to micro-scale pixel sensor areas to provide enhanced isolation of radiation-induced leakage currents. The motivation of this study is the development of AC-pixel sensors…
▽ More
The high-luminosity operation of the Tracker in the Compact Muon Solenid (CMS) detector at the Large Hadron Collider (LHC) experiment calls for the development of silicon-based sensors. This involves implementation of AC-coupling to micro-scale pixel sensor areas to provide enhanced isolation of radiation-induced leakage currents. The motivation of this study is the development of AC-pixel sensors with negative oxides (such as aluminium oxide - Al$_2$O$_3$ and hafnium oxide - HfO$_2$) as field insulators that possess good dielectric strength and provide radiation hardness. Thin films of Al$_2$O$_3$ and HfO$_2$ grown by atomic layer deposition (ALD) method were used as dielectrics for capacitive coupling. A comparison study based on dielectric material used in MOS capacitors indicate HfO$_2$ as a better candidate since it provides higher sensitivity (where, the term sensitivity is defined as the ratio of the change in flat-band voltage to dose) to negative charge accumulation with gamma irradiation.
Further, space charge sign inversion was observed for sensors processed on high resistivity p-type Magnetic Czochralski silicon (MCz-Si) substrates that were irradiated with gamma rays up to a dose of 1 MGy. The inter-pixel resistance values of heavily gamma irradiated AC-coupled pixel sensors suggest that high-$K$ negative oxides as field insulators provide a good electrical isolation between the pixels.
△ Less
Submitted 19 November, 2022; v1 submitted 16 November, 2022;
originally announced November 2022.
-
Test Beam Performance Measurements for the Phase I Upgrade of the CMS Pixel Detector
Authors:
M. Dragicevic,
M. Friedl,
J. Hrubec,
H. Steininger,
A. Gädda,
J. Härkönen,
T. Lampén,
P. Luukka,
T. Peltola,
E. Tuominen,
E. Tuovinen,
A. Winkler,
P. Eerola,
T. Tuuva,
G. Baulieu,
G. Boudoul,
L. Caponetto,
C. Combaret,
D. Contardo,
T. Dupasquier,
G. Gallbit,
N. Lumb,
L. Mirabito,
S. Perries,
M. Vander Donckt
, et al. (462 additional authors not shown)
Abstract:
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator…
▽ More
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. In this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency is $99.95\pm0.05\,\%$, while the intrinsic spatial resolutions are $4.80\pm0.25\,μ\mathrm{m}$ and $7.99\pm0.21\,μ\mathrm{m}$ along the $100\,μ\mathrm{m}$ and $150\,μ\mathrm{m}$ pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.
△ Less
Submitted 1 June, 2017;
originally announced June 2017.
-
Observation of the rare $B^0_s\toμ^+μ^-$ decay from the combined analysis of CMS and LHCb data
Authors:
The CMS,
LHCb Collaborations,
:,
V. Khachatryan,
A. M. Sirunyan,
A. Tumasyan,
W. Adam,
T. Bergauer,
M. Dragicevic,
J. Erö,
M. Friedl,
R. Frühwirth,
V. M. Ghete,
C. Hartl,
N. Hörmann,
J. Hrubec,
M. Jeitler,
W. Kiesenhofer,
V. Knünz,
M. Krammer,
I. Krätschmer,
D. Liko,
I. Mikulec,
D. Rabady,
B. Rahbaran
, et al. (2807 additional authors not shown)
Abstract:
A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six sta…
▽ More
A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six standard deviations, and the best measurement of its branching fraction so far. Furthermore, evidence for the $B^0\toμ^+μ^-$ decay is obtained with a statistical significance of three standard deviations. The branching fraction measurements are statistically compatible with SM predictions and impose stringent constraints on several theories beyond the SM.
△ Less
Submitted 17 August, 2015; v1 submitted 17 November, 2014;