-
Coherent photoproduction of the neutral pion and eta meson on the deuteron at incident energies below 1.15 GeV
Authors:
T. Ishikawa,
A. Fix,
H. Fujimura,
H. Fukasawa,
R. Hashimoto,
Q. He,
Y. Honda,
T. Iwata,
S. Kaida,
J. Kasagi,
A. Kawano,
S. Kuwasaki,
K. Maeda,
S. Masumoto,
M. Miyabe,
F. Miyahara,
K. Mochizuki,
N. Muramatsu,
A. Nakamura,
K. Nawa,
Y. Obara,
S. Ogushi,
Y. Okada,
K. Okamura,
Y. Onodera
, et al. (13 additional authors not shown)
Abstract:
Coherent photoproduction of the neutral pion and eta meson on the deuteron, $γ{d}${$\to$}$π^0η{d}$, has been experimentally studied at incident photon energies ranging from the reaction threshold to 1.15 GeV. The total cross section demonstrates a rapid rise below 1 GeV. The data are underestimated by the existing theoretical calculations based on quasi-free $π^0 η$ photoproduction on the nucleon…
▽ More
Coherent photoproduction of the neutral pion and eta meson on the deuteron, $γ{d}${$\to$}$π^0η{d}$, has been experimentally studied at incident photon energies ranging from the reaction threshold to 1.15 GeV. The total cross section demonstrates a rapid rise below 1 GeV. The data are underestimated by the existing theoretical calculations based on quasi-free $π^0 η$ photoproduction on the nucleon followed by deuteron coalescence. At the same time, the data are rather well reproduced by the calculations taking into account the final-state interaction. We have also measured for the first time the differential cross sections: the $π^0 η$ invariant-mass distribution $dσ/dM_{πη}$, the $π^0 d$ invariant-mass distribution $dσ/dM_{πd}$, the $ηd$ invariant-mass distribution $dσ/dM_{ηd}$, and the distribution over the deuteron emission angle $dσ/dΩ_d$ in the overall center-of-mass frame. The measured cross section $dσ/dΩ_d$ does not exhibit strongly backward-peaking behavior predicted by the calculations. At all incident energies, an increase in $dσ/dM_{ηd}$ near the $ηd$ threshold is observed, which indicates a bound or virtual $ηd$ state resulting from a strong attraction between $η$ and a deuteron. The possibilities of using coherent $π^0η$ photoproduction on a nucleus to study the $η$-nuclear interaction are also discussed.
△ Less
Submitted 18 March, 2022; v1 submitted 9 February, 2022;
originally announced February 2022.
-
The nylon balloon for xenon loaded liquid scintillator in KamLAND-Zen 800 neutrinoless double-beta decay search experiment
Authors:
KamLAND-Zen collaboration,
:,
Y. Gando,
A. Gando,
T. Hachiya,
S. Hayashida,
K. Hosokawa,
H. Ikeda,
T. Mitsui,
T. Nakada,
S. Obara,
H. Ozaki,
J. Shirai,
K. Ueshima,
H. Watanabe,
S. Abe,
K. Hata,
A. Hayashi,
Y. Honda,
S. Ieki,
K. Inoue,
K. Ishidoshiro,
S. Ishikawa,
Y. Kamei,
K. Kamizawa
, et al. (49 additional authors not shown)
Abstract:
The KamLAND-Zen 800 experiment is searching for the neutrinoless double-beta decay of $^{136}$Xe by using $^{136}$Xe-loaded liquid scintillator. The liquid scintillator is enclosed inside a balloon made of thin, transparent, low-radioactivity film that we call Inner Balloon (IB). The IB, apart from guaranteeing the liquid containment, also allows to minimize the background from cosmogenic muon-spa…
▽ More
The KamLAND-Zen 800 experiment is searching for the neutrinoless double-beta decay of $^{136}$Xe by using $^{136}$Xe-loaded liquid scintillator. The liquid scintillator is enclosed inside a balloon made of thin, transparent, low-radioactivity film that we call Inner Balloon (IB). The IB, apart from guaranteeing the liquid containment, also allows to minimize the background from cosmogenic muon-spallation products and $^{8}$B solar neutrinos. Indeed these events could contribute to the total counts in the region of interest around the Q-value of the double-beta decay of $^{136}$Xe. In this paper, we present an overview of the IB and describe the various steps of its commissioning minimizing the radioactive contaminations, from the material selection, to the fabrication of the balloon and its installation inside the KamLAND detector. Finally, we show the impact of the IB on the KamLAND background as measured by the KamLAND detector itself.
△ Less
Submitted 4 June, 2021; v1 submitted 21 April, 2021;
originally announced April 2021.
-
Performance evaluation of a silicon strip detector for positrons/electrons from a pulsed a muon beam
Authors:
T. Aoyagi,
Y. Honda,
H. Ikeda,
M. Ikeno,
K. Kawagoe,
T. Kohriki,
T. Kume,
T. Mibe,
K. Namba,
S. Nishimura,
N. Saito,
O. Sasaki,
N. Sato,
Y. Sato,
H. Sendai,
K. Shimomura,
S. Shirabe,
M. Shoji,
T. Suda,
T. Suehara,
T. Takatomi,
M. Tanaka,
J. Tojo,
K. Tsukada,
T. Uchida
, et al. (4 additional authors not shown)
Abstract:
A high-intensity pulsed muon beam is becoming available at the at the Japan Proton Accelerator Research Complex (J-PARC). Many experiments to study fundamental physics using this high-intensity muon beam are proposed. An experiment to measure the muon magnetic moment anomaly ($g-2$) and the muon electric dipole moment (EDM) is one of these experiments and it requires a tracking detector for positr…
▽ More
A high-intensity pulsed muon beam is becoming available at the at the Japan Proton Accelerator Research Complex (J-PARC). Many experiments to study fundamental physics using this high-intensity muon beam are proposed. An experiment to measure the muon magnetic moment anomaly ($g-2$) and the muon electric dipole moment (EDM) is one of these experiments and it requires a tracking detector for positrons from muon decay. Fine segmentation is required in a detector to tolerate the high rate of positrons. The time resolution is required to be much better than the muon anomalous spin precession period while a buffer depth of a front-end electronics needs to be much longer than the accelerated muon lifetime. Requirements of this detector also meet requirements of a measurement of the muonium hyperfine structure interval at the J-PARC and another experiment to measure the proton charge radius at Tohoku University. We have developed a single-sided silicon strip sensor with a 190 $μ$m pitch, a front-end electronics with a sampling rate of 200 MHz and a buffer memory depth of 8192, and a data acquisition system based on DAQ-Middleware for the J-PARC muon $g-2$/EDM experiment. We have fabricated detector modules consisting of this sensor and the front-end electronics. Performance of fabricated detector modules was evaluated at a laboratory and a beam test using the positron beam at Tohoku University. The detector is confirmed to satisfy all requirements of the experiments except for the time walk, which will be solved by the next version of a front-end electronics.
△ Less
Submitted 7 May, 2020; v1 submitted 29 October, 2019;
originally announced October 2019.
-
Non-strange Dibaryon Resonances Observed in the $γd\to π^0π^0 d$ Reaction
Authors:
T. Ishikawa,
H. Fujimura,
H. Fukasawa,
R. Hashimoto,
Q. He,
Y. Honda,
T. Iwata,
S. Kaida,
H. Kanda,
J. Kasagi,
A. Kawano,
S. Kuwasaki,
K. Maeda,
S. Masumoto,
M. Miyabe,
F. Miyahara,
K. Mochizuki,
N. Muramatsu,
A. Nakamura,
K. Nawa,
S. Ogushi,
Y. Okada,
K. Okamura,
Y. Onodera,
K. Ozawa
, et al. (12 additional authors not shown)
Abstract:
Coherent double neutral-pion photoproduction on the deuteron, $γ{d}${$\to$}$π^0π^0{d}$, has been experimentally studied at incident photon energies ranging from 0.75 to 1.15 GeV. The total cross section as a function of the $γ{d}$ center-of-mass energy shows resonance-like behavior, which peaks at approximately 2.47 and 2.63 GeV. The measured angular distribution of deuteron emission is rather fla…
▽ More
Coherent double neutral-pion photoproduction on the deuteron, $γ{d}${$\to$}$π^0π^0{d}$, has been experimentally studied at incident photon energies ranging from 0.75 to 1.15 GeV. The total cross section as a function of the $γ{d}$ center-of-mass energy shows resonance-like behavior, which peaks at approximately 2.47 and 2.63 GeV. The measured angular distribution of deuteron emission is rather flat, which cannot be reproduced by the kinematics of quasi-free $π^0π^0$ production with deuteron coalescence. In $π^0d $ invariant-mass distributions, a clear peak is observed at $2.14{\pm}0.01$ GeV$/c^2$ with a width of $0.09{\pm}0.01$ GeV$/c^2$. The spin-parity of this state is restricted to $1^+$, $2^+$ or $3^-$ from the angular distributions of the two $π^0$s. The present work shows strong evidence for the existence of an isovector dibaryon resonance with a mass of 2.14 GeV$/c^2$. The $2^+$ assignment is consistent with the theoretically predicted ${\cal{D}}_{12}$ state, and also with the energy dependence of the $π{d}$ partial-wave amplitude $^3\!P_2$ for the $π^{\pm}d${$\to$}$π^{\pm}d$ and $π^+d${$\to$}${pp}$ reactions.
△ Less
Submitted 9 December, 2018; v1 submitted 22 May, 2018;
originally announced May 2018.
-
Beam tuning and bunch length measurement in the bunch compression operation at the cERL
Authors:
Yosuke Honda,
Miho Shimada,
Tsukasa Miyajima,
Takahiro Hotei,
Norio Nakamura,
Ryuko Kato,
Takashi Obina,
Ryota Takai,
Kentaro Harada,
Akira Ueda
Abstract:
Realization of a short bunch beam by manipulating the longitudinal phase space distribution with a finite longitudinal dispersion following an off-crest accelera- tion is a widely used technique. The technique was applied in a compact test accelerator of an energy-recovery linac scheme for compressing the bunch length at the return loop. A diagnostic system utilizing coherent transition radiation…
▽ More
Realization of a short bunch beam by manipulating the longitudinal phase space distribution with a finite longitudinal dispersion following an off-crest accelera- tion is a widely used technique. The technique was applied in a compact test accelerator of an energy-recovery linac scheme for compressing the bunch length at the return loop. A diagnostic system utilizing coherent transition radiation was developed for the beam tuning and for estimating the bunch length. By scanning the beam parameters, we experimentally found the best condition for the bunch compression. The RMS bunch length of 250+-50 fs was obtained at a bunch charge of 2 pC. This result confirmed the design and the tuning pro- cedure of the bunch compression operation for the future energy-recovery linac (ERL).
△ Less
Submitted 30 August, 2017;
originally announced September 2017.
-
Principal Component Analysis of Cavity Beam Position Monitor Signals
Authors:
Y. I. Kim,
S. T. Boogert,
Y. Honda,
A. Lyapin,
H. Park,
N. Terunuma,
T. Tauchi,
J. Urakawa
Abstract:
Model-independent analysis (MIA) methods are generally useful for analysing complex systems in which relationships between the observables are non-trivial and noise is present. Principle Component Analysis (PCA) is one of MIA methods allowing to isolate components in the input data graded to their contribution to the variability of the data. In this publication we show how the PCA can be applied t…
▽ More
Model-independent analysis (MIA) methods are generally useful for analysing complex systems in which relationships between the observables are non-trivial and noise is present. Principle Component Analysis (PCA) is one of MIA methods allowing to isolate components in the input data graded to their contribution to the variability of the data. In this publication we show how the PCA can be applied to digitised signals obtained from a cavity beam position monitor (CBPM) system on the example of a 3-cavity test system installed at the Accelerator Test Facility 2 (ATF2) at KEK in Japan. We demonstrate that the PCA based method can be used to extract beam position information, and matches conventional techniques in terms of performance, while requiring considerably less settings and data for calibration.
△ Less
Submitted 3 March, 2014; v1 submitted 18 November, 2013;
originally announced November 2013.
-
Photon generation by laser-Compton scattering at the KEK-ATF
Authors:
Shuhei Miyoshi,
Tomoya Akagi,
Sakae Araki,
Yoshisato Funahashi,
Tachishige Hirose,
Yosuke Honda,
Masao Kuriki,
Xiao Li,
Toshiyuki Okugi,
Tsunehiko Omori,
Guoxi Pei,
Kazuyuki Sakaue,
Hirotaka Shimizu,
Tohru Takahashi,
Nobuhiro Terunuma,
Junji Urakawa,
Yasuaki Ushio,
Masakazu Washio
Abstract:
We performed a photon generation experiment by laser-Compton scattering at the KEK-ATF, aiming to develop a Compton based polarized positron source for linear colliders. In the experiment, laser pulses with a 357 MHz repetition rate were accumulated and their power was enhanced by up to 250 times in the Fabry-Perot optical resonant cavity. We succeeded in synchronizing the laser pulses and colli…
▽ More
We performed a photon generation experiment by laser-Compton scattering at the KEK-ATF, aiming to develop a Compton based polarized positron source for linear colliders. In the experiment, laser pulses with a 357 MHz repetition rate were accumulated and their power was enhanced by up to 250 times in the Fabry-Perot optical resonant cavity. We succeeded in synchronizing the laser pulses and colliding them with the 1.3 GeV electron beam in the ATF ring while maintaining the laser pulse accumulation in the cavity. As a result, we observed 26.0 +/- 0.1 photons per electron-laser pulse crossing, which corresponds to a yield of 10^8 photons in a second.
△ Less
Submitted 18 February, 2010;
originally announced February 2010.
-
Design of a Nanometer Beam Size Monitor for ATF2
Authors:
Taikan Suehara,
Masahiro Oroku,
Takashi Yamanaka,
Hakutaro Yoda,
Tomoya Nakamura,
Yoshio Kamiya,
Yosuke Honda,
Tatsuya Kume,
Toshiaki Tauchi,
Tomoyuki Sanuki,
Sachio Komamiya
Abstract:
We developed an electron beam size monitor for extremely small beam sizes. It uses a laser interference fringe for a scattering target with the electron beam. Our target performance is < 2 nm systematic error for 37 nm beam size and < 10% statistical error in a measurement using 90 electron bunches for 25 - 6000 nm beam size. A precise laser interference fringe control system using an active fee…
▽ More
We developed an electron beam size monitor for extremely small beam sizes. It uses a laser interference fringe for a scattering target with the electron beam. Our target performance is < 2 nm systematic error for 37 nm beam size and < 10% statistical error in a measurement using 90 electron bunches for 25 - 6000 nm beam size. A precise laser interference fringe control system using an active feedback function is incorporated to the monitor to achieve the target performance. We describe an overall design, implementations, and performance estimations of the monitor.
△ Less
Submitted 30 October, 2008;
originally announced October 2008.