Skip to main content

Showing 1–6 of 6 results for author: Bortfeldt, J

Searching in archive hep-ex. Search in all archives.
.
  1. arXiv:2406.08712  [pdf, other

    physics.ins-det hep-ex

    A Novel Diamond-like Carbon based photocathode for PICOSEC Micromegas detectors

    Authors: X. Wang, R. Aleksan, Y. Angelis, J. Bortfeldt, F. Brunbauer, M. Brunoldi, E. Chatzianagnostou, J. Datta, K. Degmelt, G. Fanourakis, D. Fiorina, K. J. Floethner, M. Gallinaro, F. Garcia, I. Giomataris, K. Gnanvo, F. J. Iguaz, D. Janssens, A. Kallitsopoulou, M. Kovacic, B. Kross, P. Legou, M. Lisowska, J. Liu, I. Maniatis , et al. (26 additional authors not shown)

    Abstract: The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. However, due to the high hygroscopicity and susceptibility to ion bomb… ▽ More

    Submitted 30 July, 2024; v1 submitted 12 June, 2024; originally announced June 2024.

  2. arXiv:2203.06562  [pdf, other

    physics.ins-det hep-ex nucl-ex

    Snowmass 2021 White Paper Instrumentation Frontier 05 -- White Paper 1: MPGDs: Recent advances and current R&D

    Authors: K. Dehmelt, M. Della Pietra, H. Muller, S. E. Tzamarias, A. White, S. White, Z. Zhang, M. Alviggi, I. Angelis, S. Aune, J. Bortfeldt, M. Bregant, F. Brunbauer, M. T. Camerlingo, V. Canale, V. D'Amico, D. Desforge, C. Di Donato, R. Di Nardo, G. Fanourakis, K. J. Floethner, M. Gallinaro, F. Garcia, I. Giomataris, K. Gnanvo , et al. (45 additional authors not shown)

    Abstract: This paper will review the origins, development, and examples of new versions of Micro-Pattern Gas Detectors. The goal for MPGD development was the creation of detectors that could cost-effectively cover large areas while offering excellent position and timing resolution, and the ability to operate at high incident particle rates. The early MPGD developments culminated in the formation of the RD51… ▽ More

    Submitted 19 March, 2022; v1 submitted 12 March, 2022; originally announced March 2022.

    Comments: Contribution to Snowmass 2021

  3. arXiv:2012.00545  [pdf, other

    physics.ins-det hep-ex

    Timing performance of a multi-pad PICOSEC-Micromegas detector prototype

    Authors: S. Aune, J. Bortfeldt, F. Brunbauer, C. David, D. Desforge, G. Fanourakis, M. Gallinaro, F. García, I. Giomataris, T. Gustavsson, F. J. Iguaz, M. Kebbiri, K. Kordas, C. Lampoudis, P. Legou, M. Lisowska, J. Liu, M. Lupberger, O. Maillard, I. Manthos, H. Müller, E. Oliveri, T. Papaevangelou, K. Paraschou, M. Pomorski , et al. (17 additional authors not shown)

    Abstract: The multi-pad PICOSEC-Micromegas is an improved detector prototype with a segmented anode, consisting of 19 hexagonal pads. Detailed studies are performed with data collected in a muon beam over four representative pads. We demonstrate that such a device, scalable to a larger area, provides excellent time resolution and detection efficiency. As expected from earlier single-cell device studies, we… ▽ More

    Submitted 28 January, 2021; v1 submitted 1 December, 2020; originally announced December 2020.

    Comments: 29 pages, 20 figures

  4. arXiv:1808.09752  [pdf, other

    physics.ins-det hep-ex

    Construction techniques and performances of a full-size prototype Micromegas chamber for the ATLAS muon spectrometer upgrade

    Authors: T. Alexopoulos, M. Alviggi, M. Antonelli, F. Anulli, C. Arcangeletti, P. Bagnaia, A. Baroncelli, M. Beretta, C. Bini, J. Bortfeldt, D. Calabrò, V. Canale, G. Capradossi, G. Carducci, A. Caserio, C. Cassese, S. Cerioni, G. Ciapetti, V. D' Amico, B. De Fazio, M. Del Gaudio, C. Di Donato, R. Di Nardo, D. D' Uffizi, E. Farina , et al. (54 additional authors not shown)

    Abstract: A full-size prototype of a Micromegas precision tracking chamber for the upgrade of the ATLAS detector at the LHC Collider has been built between October 2015 and April 2016. This paper describes in detail the procedures used in constructing the single modules of the chamber in various INFN laboratories and the final assembly at the Laboratori Nazionali di Frascati (LNF). Results of the chamber ex… ▽ More

    Submitted 11 September, 2018; v1 submitted 29 August, 2018; originally announced August 2018.

    Comments: Contact editors: G. Mancini, A. Kourkoumeli-Charalampidi

  5. arXiv:1508.00802  [pdf, other

    physics.ins-det hep-ex

    High-Rate Capable Floating Strip Micromegas

    Authors: Jonathan Bortfeldt, Michael Bender, Otmar Biebel, Helge Danger, Bernhard Flierl, Ralf Hertenberger, Philipp Lösel, Samuel Moll, Katia Parodi, Ilaria Rinaldi, Alexander Ruschke, André Zibell

    Abstract: We report on the optimization of discharge insensitive floating strip Micromegas (MICRO-MEsh GASeous) detectors, fit for use in high-energy muon spectrometers. The suitability of these detectors for particle tracking is shown in high-background environments and at very high particle fluxes up to 60MHz/cm$^2$. Measurement and simulation of the microscopic discharge behavior have demonstrated the ex… ▽ More

    Submitted 4 August, 2015; originally announced August 2015.

    Comments: Presented at ICHEP 2014, accepted for publication in Nuclear Physics B Proceedings Supplements

  6. arXiv:1201.2062  [pdf, other

    physics.ins-det hep-ex

    Development of High-Resolution Muon Tracking Systems Based on Micropattern Detectors

    Authors: Jonathan Bortfeldt, Otmar Biebel, David Heereman, Ralf Hertenberger

    Abstract: A muon tracking system consisting of four 9cm x 10cm sized bulk Micromegas detectors with 128um amplification-gap and two 10cm x 10cm triple GEM detectors is foreseen for high-precision tracking of 140GeV muons at the H8 beamline at CERN with a rate of up to 10kHz and an overall resolution below 40um. Larger detectors with an active area of 0.5m^2 and more are under development for detector studie… ▽ More

    Submitted 10 January, 2012; originally announced January 2012.

    Comments: 6 pages, 12 figures, To be published in the Proceedings of the Second International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications - ANIMMA (2011)