Skip to main content

Showing 1–5 of 5 results for author: ArDM Collaboration

Searching in archive hep-ex. Search in all archives.
.
  1. arXiv:1712.01932  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Backgrounds and pulse shape discrimination in the ArDM liquid argon TPC

    Authors: ArDM Collaboration, J. Calvo, C. Cantini, P. Crivelli, M. Daniel, S. Di Luise, A. Gendotti, S. Horikawa, L. Molina-Bueno, B. Montes, W. Mu, S. Murphy, G. Natterer, K. Nguyen, L. Periale, Y. Quan, B. Radics, C. Regenfus, L. Romero, A. Rubbia, R. Santorelli, F. Sergiampietri, T. Viant, S. Wu

    Abstract: The ArDM experiment completed a single-phase commissioning run in 2015 with an active liquid argon target of nearly one tonne in mass. The analysis of the data and comparison to simulations allowed for a test of the crucial detector properties and confirmed the low background performance of the setup. The statistical rejection power for electron recoil events using the pulse shape discrimination m… ▽ More

    Submitted 2 December, 2017; originally announced December 2017.

    Comments: 17 pages, 10 figures

  2. arXiv:1612.06375  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    The ArDM Liquid Argon Time Projection Chamber at the Canfranc Underground Laboratory: a ton-scale detector for Dark Matter Searches

    Authors: ArDM Collaboration, J. Calvo, C. Cantini, P. Crivelli, M. Daniel, S. DiLuise, A. Gendotti, S. Horikawa, B. Montes, W. Mu, S. Murphy, G. Natterer, K. Ngyuen, L. Periale, Y. Quan, B. Radics, C. Regenfus, L. Romero, A. Rubbia, R. Santorelli, F. Sergiampietri, T. Viant, S. Wu

    Abstract: The Argon Dark Matter (ArDM) experiment consists of a liquid argon (LAr) time projection chamber (TPC) sensitive to nuclear recoils resulting from scattering of hypothetical Weakly Interacting Massive Particles (WIMPs) on argon targets. With an active target of 850 kg, ArDM represents an important milestone in the quest for Dark Matter with LAr. We present the experimental apparatus currently inst… ▽ More

    Submitted 19 December, 2016; originally announced December 2016.

    Comments: 30 pages, 18 figures

  3. arXiv:1611.02481  [pdf, other

    astro-ph.IM hep-ex physics.ins-det

    Measurement of the attenuation length of argon scintillation light in the ArDM LAr TPC

    Authors: ArDM Collaboration, J. Calvo, C. Cantini, P. Crivelli, M. Daniel, S. DiLuise, A. Gendotti, S. Horikawa, L. Molina-Bueno, B. Montes, W. Mu, S. Murphy, G. Natterer, K. Ngyuen, L. Periale, Y. Quan, B. Radics, C. Regenfus, L. Romero, A. Rubbia, R. Santorelli, F. Sergiampietri, T. Viant, S. Wu

    Abstract: We report on a measurement of the attenuation length for the scintillation light in the tonne size liquid argon target of the ArDM dark matter experiment. The data was recorded in the first underground operation of the experiment in single-phase operational mode. The results were achieved by comparing the light yield spectra from 39-Ar and 83m-Kr to a description of the ArDM setup with a model of… ▽ More

    Submitted 8 November, 2016; originally announced November 2016.

    Comments: 20 pages, 8 figures

  4. arXiv:1505.02443  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Status of ArDM-1t: First observations from operation with a full ton-scale liquid argon target

    Authors: ArDM Collaboration, J. Calvo, C. Cantini, M. Daniel, U. Degunda, S. Di Luise, L. Epprecht, A. Gendotti, S. Horikawa, L. Knecht, B. Montes, W. Mu, M. Munoz, S. Murphy, G. Natterer, K. Nguyen, K. Nikolics, L. Periale, C. Regenfus, L. Romero, A. Rubbia, R. Santorelli, F. Sergiampietri, D. Sgalaberna, T. Viant , et al. (1 additional authors not shown)

    Abstract: ArDM-1t is the first operating ton-scale liquid argon detector for direct search of Dark Matter particles. Developed at CERN as Recognized Experiment RE18, the experiment has been approved in 2010 to be installed in the Spanish underground site LSC (Laboratorio Subterraneo de Canfranc). Under the label of LSC EXP-08-2010 the ArDM detector underwent an intensive period of technical completion and s… ▽ More

    Submitted 10 May, 2015; originally announced May 2015.

    Comments: 16 pages, 18 figures

  5. arXiv:1006.5335  [pdf, ps, other

    physics.ins-det astro-ph.IM hep-ex

    The ArDM experiment

    Authors: ArDM Collaboration, C. Amsler, A. Badertscher, V. Boccone, N. Bourgeois, A. Bueno, M. C. Carmona-Benitez, M. Chorowski, W. Creus, A. Curioni, E. Daw, U. Degunda, A. Dell'Antone, M. Droge, L. Epprecht, C. Haller, M. Haranczyk, S. Horikawa, L. Kaufmann, J. Kisiel, L. Knecht, M. Laffranchi, J. Lagoda, C. Lazzaro, P. Lightfoot , et al. (29 additional authors not shown)

    Abstract: The aim of the ArDM project is the development and operation of a one ton double-phase liquid argon detector for direct Dark Matter searches. The detector measures both the scintillation light and the ionization charge from ionizing radiation using two independent readout systems. This paper briefly describes the detector concept and presents preliminary results from the ArDM R&D program, includin… ▽ More

    Submitted 28 June, 2010; originally announced June 2010.

    Comments: Proceedings of the Epiphany 2010 Conference, to be published in Acta Physica Polonica B

    Journal ref: Acta Phys.Polon.B41:1441-1446,2010