In-orbit performance and calibration of the Hard X-ray Imager onboard Hitomi (ASTRO-H)
Authors:
Kouichi Hagino,
Kazuhiro Nakazawa,
Goro Sato,
Motohide Kokubun,
Teruaki Enoto,
Yasushi Fukazawa,
Katsuhiro Hayashi,
Jun Kataoka,
Junichiro Katsuta,
Shogo B. Kobayashi,
Philippe Laurent,
Francois Lebrun,
Olivier Limousin,
Daniel Maier,
Kazuo Makishima,
Taketo Mimura,
Katsuma Miyake,
Tsunefumi Mizuno,
Kunishiro Mori,
Hiroaki Murakami,
Takeshi Nakamori,
Toshio Nakano,
Hirofumi Noda,
Hirokazu Odaka,
Masanori Ohno
, et al. (15 additional authors not shown)
Abstract:
The Hard X-ray Imager (HXI) onboard Hitomi (ASTRO-H) is an imaging spectrometer covering hard X-ray energies of 5-80 keV. Combined with the hard X-ray telescope, it enables imaging spectroscopy with an angular resolution of $1^\prime.7$ half-power diameter, in a field of view of $9^\prime\times9^\prime$. The main imager is composed of 4 layers of Si detectors and 1 layer of CdTe detector, stacked…
▽ More
The Hard X-ray Imager (HXI) onboard Hitomi (ASTRO-H) is an imaging spectrometer covering hard X-ray energies of 5-80 keV. Combined with the hard X-ray telescope, it enables imaging spectroscopy with an angular resolution of $1^\prime.7$ half-power diameter, in a field of view of $9^\prime\times9^\prime$. The main imager is composed of 4 layers of Si detectors and 1 layer of CdTe detector, stacked to cover wide energy band up to 80 keV, surrounded by an active shield made of BGO scintillator to reduce the background. The HXI started observations 12 days before the Hitomi loss, and successfully obtained data from G21.5$-$0.9, Crab and blank sky. Utilizing these data, we calibrate the detector response and study properties of in-orbit background. The observed Crab spectra agree well with a powerlaw model convolved with the detector response, within 5% accuracy. We find that albedo electrons in specified orbit strongly affect the background of Si top layer, and establish a screening method to reduce it. The background level over the full field of view after all the processing and screening is as low as the pre-flight requirement of $1$-$3\times10^{-4}$ counts s$^{-1}$ cm$^{-2}$ keV$^{-1}$.
△ Less
Submitted 21 May, 2018;
originally announced May 2018.
Modeling of proton-induced radioactivation background in hard X-ray telescopes: Geant4-based simulation and its demonstration by Hitomi's measurement in a low Earth orbit
Authors:
Hirokazu Odaka,
Makoto Asai,
Kouichi Hagino,
Tatsumi Koi,
Greg Madejski,
Tsunefumi Mizuno,
Masanori Ohno,
Shinya Saito,
Tamotsu Sato,
Dennis H. Wright,
Teruaki Enoto,
Yasushi Fukazawa,
Katsuhiro Hayashi,
Jun Kataoka,
Junichiro Katsuta,
Madoka Kawaharada,
Shogo B. Kobayashi,
Motohide Kokubun,
Philippe Laurent,
Francois Lebrun,
Olivier Limousin,
Daniel Maier,
Kazuo Makishima,
Taketo Mimura,
Katsuma Miyake
, et al. (25 additional authors not shown)
Abstract:
Hard X-ray astronomical observatories in orbit suffer from a significant amount of background due to radioactivation induced by cosmic-ray protons and/or geomagnetically trapped protons. Within the framework of a full Monte Carlo simulation, we present modeling of in-orbit instrumental background dominated by radioactivation. To reduce the computation time required by straightforward simulations o…
▽ More
Hard X-ray astronomical observatories in orbit suffer from a significant amount of background due to radioactivation induced by cosmic-ray protons and/or geomagnetically trapped protons. Within the framework of a full Monte Carlo simulation, we present modeling of in-orbit instrumental background dominated by radioactivation. To reduce the computation time required by straightforward simulations of delayed emissions from activated isotopes, we insert a semi-analytical calculation that converts production probabilities of radioactive isotopes by interaction of the primary protons into decay rates at measurement time of all secondary isotopes. Therefore, our simulation method is separated into three steps: (1) simulation of isotope production, (2) semi-analytical conversion to decay rates, and (3) simulation of decays of the isotopes at measurement time. This method is verified by a simple setup that has a CdTe semiconductor detector, and shows a 100-fold improvement in efficiency over the straightforward simulation. The simulation framework was tested against data measured with a CdTe sensor in the Hard X-ray Imager onboard the Hitomi X-ray Astronomy Satellite, which was put into a low Earth orbit with an altitude of 570 km and an inclination of 31 degrees, and thus experienced a large amount of irradiation from geomagnetically trapped protons during its passages through the South Atlantic Anomaly. The simulation is able to treat full histories of the proton irradiation and multiple measurement windows. The simulation results agree very well with the measured data, showing that the measured background is well described by the combination of proton-induced radioactivation of the CdTe detector itself and thick Bi4Ge3O12 scintillator shields, leakage of cosmic X-ray background and albedo gamma-ray radiation, and emissions from naturally contaminated isotopes in the detector system.
△ Less
Submitted 3 April, 2018;
originally announced April 2018.