CERN Accelerating science

CERN Document Server 找到 2,033 笔记录  1 - 10下一个最後  跳到记录: 检索需时 0.18 秒. 
1.
Some Results of MCP Timing Resolution Measurements with Minimum Ionizing Particles / Efimov, L G ; Feofilov, G A ; Filippov, S N ; Pantuev, V S ; Valiev, F F /ALICE Collaboration
First results of the timing resolution tests done with 800 MeV/c pion and proton beams for the MCP-based multipad detector are reported. Two chevron stacks of multichannel plate (MCP) detectors with 43 63 mm2 sensitive area were used together with the multipad readout anodes. [...]
ALICE-INT-1994-06; CERN-ALICE-INT-1994-06.- Geneva : CERN, 1994
2.
The new MCP-based TOF system / Gevorkov, L G ; Kurepin, A B ; Laptev, V D ; Patarakin, O O ; Valiev, F F /ALICE Collaboration
The particle identification in the 1/beta**2 region is proposed to be done by the specially designed detector based on microchannel plates (MCPs) application..
ALICE-INT-1992-08; CERN-ALICE-INT-1992-08.- Geneva : CERN, 1992
3.
Results of in-beam tests of an MCP-based vacuum sector prototype of the T0/centrality detector for ALICE / Bondila, M ; Efimov, L ; Hatzifotiadou, D ; Feofilov, G A ; Kondratev, V A ; Lyapin, V G ; Nysten, J ; Otiougova, P ; Tulina, T A ; Trzaska, W H et al.
2002 - Published in : Nucl. Instrum. Methods Phys. Res., A 478 (2002) 220-4
4.
Fast front-end L0 trigger electronics for ALICE FMD-MCP tests and performance / Efimov, L G ; Feofilov, G A ; Kasatkan, V ; Klempt, W ; Kuts, V ; Lenti, V ; Platanov, V ; Rudge, A ; Stolyarov, O I ; Tsimbal, F A et al.
We present design details and new measurements of the performance of fast electronics for the Forward Multiplicity Detector for ALICE. These detectors based on sector type Microchannel Plates (MCP) forming several disks gave the very first trigger decision in the experiment (L0) [...]
CERN-ALI-97-10; CERN-ALICE-PUB-97-10.- Geneva : CERN, 1997 Fulltext: PDF;
In : 3rd Workshop on Electronics for LHC Experiments, London, UK, 22 - 26 Sep 1997, pp.359-363
5.
Sector Multipad Prototype of the FMD-MCP Detector for ALICE (1997) / Antropov, A E ; Fedotov, A V ; Feofilov, G A ; Izrailov, E K ; Kasatkin, V A ; Klempt, W ; Kolojvari, A A ; Larin, M P ; Lazarev, V A ; Novikov, I A et al.
We present results of the technology, manufacturing andfirst tests of a novel MCP-based sector prototypefor the Forward Multiplicity Detector for the ALICE experiment at the LHC [...]
CERN-ALI-97-15 ; CERN-ALICE-PUB-97-15.
- 1997.
Fulltext
6.
Fast Pre-Trigger Electronics of T0/Centrality MCP-Based Start Detector for ALICE / ALICE Collaboration
This work describes an alternative to the current ALICE baseline solution for a TO detector, still under development. The proposed system consists of two MCP-based T0/Centrality Start Detectors (backward-forward isochronous disks) equipped with programmable, TTC synchronized front-end electronic cards (FEECs) which would be positioned along the LHC colliding beam line on both sides of the ALICE interaction region. [...]
CERN-ALI-2001-027; CERN-ALICE-PUB-2001-27.- Geneva : CERN, 2001 - 6 p. Fulltext: PDF; Published version from CERN: PDF;
In : 7th Workshop on Electronics for LHC Experiments, Stockholm, Sweden, 10 - 14 Sep 2001, pp.273-277 (CERN-2001-005) - CERN library copies
7.
MCP-based detectors: A compact compilation of recent developments / Valiev, F F /ALICE Collaboration
We present a compilation compressed to a table form of the parameters of some recently developed position-sensitive detectors based on the application of microchannel plates (MCPs) for the registration of various sorts of radiations in a wide region of energies..
ALICE-INT-1992-09; CERN-ALICE-INT-1992-09.- Geneva : CERN, 1992
8.
The MCP-based vertex detector / Gevorkov, L G ; Kurepin, A B ; Laptev, V D ; Patarakin, O O ; Valiev, F F /ALICE Collaboration
We discuss the possible application of large area microchannel plates (MCPs) as a basic Abstract: element of a vertex detector unit. Two types of basic modules : (MCP + Delay Line) and (MCP + Microstrips) are suggested. [...]
ALICE-INT-1992-07; CERN-ALICE-INT-1992-07.- Geneva : CERN, 1992
9.
Position-Sensitive MCP-based Detectors with High Timing Resolution: Some Results and Perspectives / Stolyarov, O I (St. Petersburg State U.) ; Tsimbal, F A (St. Petersburg State U.) ; Valiev, F F (St. Petersburg State U.) ; Vinogradov, L I (St. Petersburg State U.) /ALICE Collaboration
The microelectronic design and some results of experimental tests of three types of coordinate sensitive Micro-Channel-Plate (MCP)-based detectors with high timing properties are presented. The electrodynamic structures that could be used for the MCP fast signal readout (strips, delay lines and discrete pads) are always a compromise between the amplitude of the induced signal, propagation time delay, cross-talk and distortions of the signal at the output. [...]
ALICE-INT-1995-07; CERN-ALICE-INT-1995-07.- Geneva : CERN, 1995 - Published in : Nucl. Instrum. Methods. Phys. Res., A 367 (1995) 402-407
10.
Sector multipad prototype of the FMD-MCP detector for ALICE / ALICE Collaboration
1998 - Published in : Nucl. Instrum. Methods Phys. Res., A 419 (1998) 654-659

没有寻找到什么? 尝试在以下的服务器查寻:
recid:689399 在 Amazon
recid:689399 在 CERN EDMS
recid:689399 在 CERN Intranet
recid:689399 在 CiteSeer
recid:689399 在 Google Books
recid:689399 在 Google Scholar
recid:689399 在 Google Web
recid:689399 在 IEC
recid:689399 在 IHS
recid:689399 在 INSPIRE
recid:689399 在 ISO
recid:689399 在 KISS Books/Journals
recid:689399 在 KISS Preprints
recid:689399 在 NEBIS
recid:689399 在 SLAC Library Catalog