1.
|
|
2.
|
The Phase-I Trigger Readout Electronics Upgrade of the ATLAS Liquid Argon Calorimeters
/ Aad, G. (Marseille, CPPM) ; Akimov, A.V. (CERN ; LPI, Moscow (main)) ; Al Khoury, K. (Nevis Labs, Columbia U.) ; Aleksa, M. (CERN) ; Andeen, T. (Arizona U.) ; Anelli, C. (Victoria U.) ; Aranzabal, N. (CERN) ; Armijo, C. (Arizona U.) ; Bagulia, A. (Lebedev Inst.) ; Ban, J. (Nevis Labs, Columbia U.) et al.
The Phase-I trigger readout electronics upgrade of the ATLAS Liquid Argon calorimeters enhances the physics reach of the experiment during the upcoming operation at increasing Large Hadron Collider luminosities. The new system, installed during the second Large Hadron Collider Long Shutdown, increases the trigger readout granularity by up to a factor of ten as well as its precision and range. [...]
arXiv:2202.07384.-
2022-05-16 - 56 p.
- Published in : JINST 17 (2022) P05024
Fulltext: document - PDF; 2202.07384 - PDF; Publication - PDF;
|
|
3.
|
Design and Evaluation of the LAr Trigger Digitizer Board in the ATLAS Phase-I Upgrade
/ Besin, Dominique (Brookhaven Natl. Lab.) ; Chen, Hucheng (Brookhaven Natl. Lab.) ; Chen, Kai (Brookhaven Natl. Lab.) ; Citterio, Mauro (INFN, Milan) ; Deschamps, Herve (Saclay) ; Grabas, Aude (Saclay) ; Lanni, Francesco (Brookhaven Natl. Lab.) ; Latorre, Stefano (INFN, Milan) ; Lazzaroni, Massimo (INFN, Milan) ; Liu, Hongbin (Brookhaven Natl. Lab.) et al.
The LHC upgrade is planned to enhance the instantaneous luminosity during Run 3 from 2021 through 2023. The Phase-I upgrade of the trigger readout electronics for the ATLAS Liquid Argon (LAr) Calorimeters will be installed during the second long shutdown of LHC in 2019-2020. [...]
arXiv:1806.08046.-
2019-06-24 - 6 p.
- Published in : IEEE Trans. Nucl. Sci. 66 (2019) 2011-2016
Fulltext: PDF;
In : 21st IEEE Real Time Conference, Williamsburg, Va, United States Of America, 9 - 15 Jun 2018, pp.2011-2016
|
|
4.
|
Fast photon-detection for COMPASS RICH-1
/ Chiosso, Michela (INFN, Turin ; U. Turin (main)) ; Abbon, P (DSM, DAPNIA, Saclay) ; Alexeev, M (Piemonte Orientale U., Alessandria ; INFN, Turin) ; Angerer, H (Munich, Tech. U.) ; Birsa, R (INFN, Trieste) ; Bordalo, P (LIP, Lisbon) ; Bradamante, F (INFN, Trieste ; U. Trieste (main)) ; Bressan, A (U. Trieste (main) ; INFN, Trieste) ; Ciliberti, P (INFN, Trieste ; U. Trieste (main)) ; Colantoni, M L (INFN, Turin) et al.
A fast photon-detection system for the detector RICH-1 of the COMPASS Experiment at CERN SPS is in operation since the 2006 run. It is based on the use of Multi-Anode Photomultipliers (MAPMTs) coupled to individual fused silica lens telescopes and fast read-out electronics. [...]
2008
- Published in : 10.1142/9789812819093_0007
In : 10th ICATPP Conference on Astroparticle, Particle, Space Physics, Detectors and Medical Physics Applications, Villa Olmo, Como, Italy, 8 - 12 Oct 2007, pp.45-49
|
|
5.
|
Fast Photon Detection for COMPASS RICH1
/ Abbon, P (DSM, DAPNIA, Saclay) ; Alekseev, M (INFN, Turin ; Turin U.) ; Angerer, H (Munich, Tech. U.) ; Apollonio, M (INFN, Trieste ; Trieste U.) ; Birsa, R (INFN, Trieste ; Trieste U.) ; Bordalo, P (Lisbon, LIFEP) ; Bradamante, F (INFN, Trieste ; Trieste U.) ; Bressan, A (INFN, Trieste ; Trieste U.) ; Busso, L (INFN, Turin ; Turin U.) ; Chiosso, M (INFN, Turin ; Turin U.) et al.
The new photon detection system for COMPASS RICH-1 has been designed to cope with the demanding requests of operation at high beam intensity and at high trigger rates. The detection technique in the central region of RICH-1 has been changed with a system based on multianode photomultipliers coupled to individual fused silica lens telescopes and to a fast, almost dead time free readout system based on the MAD-4 amplifier-discriminator and the F1 TDC-chip. [...]
2006 - 8 p.
- Published in : Czechoslov. J. Phys. 56 (2006) F317
Fulltext: PDF;
In : Advanced Studies Institution Symmetries and Spin, Prague, Czech Republic, 19 - 26 Jul 2006, pp.317
|
|
6.
|
Optical telescopes for COMPASS RICH1 up-grade
/ Sulc, M (Liberec Tech. U.) ; Abbon, P (DSM, DAPNIA, Saclay) ; Alekseev, M (INFN, Turin ; Turin U.) ; Angerer, H (Munich, Tech. U.) ; Appolonio, M (INFN, Trieste ; Trieste U.) ; Birsa, R (INFN, Trieste ; Trieste U.) ; Bordalo, P (Lisbon, LIFEP) ; Bradamante, F (INFN, Trieste ; Trieste U.) ; Bressan, A (INFN, Trieste ; Trieste U.) ; Busso, L (INFN, Turin ; Turin U.) et al.
The central photon detection area of the Ring Imaging Cherenkov detector at COMPASS, a particle physics experiment at CERN SPS dedicated to hadron physics, has been upgraded from the previous system formed by wire chambers with CsI layers to a very fast UV extended multi anode photo multiplier tube array (MAPMT), including 576 tubes. The active area covered by the MAPMTs is 7.3 times smaller than the one previously equipped with CsI photocathodes, so 576 optical concentrators transforming the image from the old system focal plane to the new photocathode plane were needed. [...]
2006 - 8 p.
- Published in : Czechoslov. J. Phys. 56 (2006) F325
Fulltext: PDF;
In : Advanced Studies Institution Symmetries and Spin, Prague, Czech Republic, 19 - 26 Jul 2006, pp.325
|
|
7.
|
Hartmann test of the COMPASS RICH-1 optical telescopes
/ Polak, J (Liberec Tech. U.) ; Abbon, P (DSM, DAPNIA, Saclay) ; Alekseev, M (INFN, Turin ; Turin U.) ; Angerer, H (Munich, Tech. U.) ; Apollonio, M (Trieste U. ; INFN, Trieste) ; Birsa, R (Trieste U. ; INFN, Trieste) ; Bordalo, P (Lisbon, LIFEP) ; Bradamante, F (Trieste U. ; INFN, Trieste) ; Bressan, A (Trieste U. ; INFN, Trieste) ; Busso, L (INFN, Turin ; Turin U.) et al.
The central region of COMPASS RICH-1 has been equipped with a new photon detection system based on MultiAnode PhotoMultiplier Tubes (MAPMT). The Cherenkov photons are focused by an array of 576 fused silica telescopes onto 576 MAPMTs. [...]
2008 - 6 p.
- Published in : Czechoslov. J. Phys. 56 (2006) F333
Fulltext: PDF;
In : Advanced Studies Institution Symmetries and Spin, Prague, Czech Republic, 19 - 26 Jul 2006, pp.333
|
|
8.
|
The experience of building and operating COMPASS RICH-1
/ Birsa, R (INFN, Trieste) ; Eyrich, W (Erlangen - Nuremberg U.) ; Rocco, E (Turin U. ; INFN, Turin) ; Schiavon, P (Trieste U. ; INFN, Trieste) ; Kramer, D (Liberec Tech. U.) ; Schroder, W (Erlangen - Nuremberg U.) ; Dafni, T (DSM, DAPNIA, Saclay) ; Tessarotto, F (INFN, Trieste) ; Bressan, A (Trieste U. ; INFN, Trieste) ; Schill, C (Freiburg U.) et al.
COMPASS RICH-1 is a large size gaseous Imaging Cherenkov Detector providing hadron identification in the range from 3 to 55 GeV/c, in the wide acceptance spectrometer of the COMPASS Experiment at CERN SPS. It uses a 3 m long C(4)F(10) radiator, a 21 m(2) large VUV mirror surface and two kinds of photon detectors: MAPMTs and MWPCs with CsI photocathodes, covering a total of 5.5 m(2). [...]
2011
- Published in : Nucl. Instrum. Methods Phys. Res., A 639 (2011) 15-19
In : 7th International Workshop on Ring Imaging Cherenkov Detectors, Cassis, Provence, France, 3 - 7 May 2010, pp.15-19
|
|
9.
|
Particle identification with COMPASS RICH-1
/ Abbon, P (DSM, DAPNIA, Saclay) ; Alexeev, M (Piemonte Orientale U., Alessandria ; INFN, Turin) ; Angerer, H (Munich, Tech. U.) ; Birsa, R (INFN, Trieste) ; Bordalo, P (Lisbon, LIFEP) ; Bradamante, F (Trieste U. ; INFN, Trieste) ; Bressan, A (Trieste U. ; INFN, Trieste) ; Chiosso, M (Turin U. ; INFN, Turin) ; Ciliberti, P (Trieste U. ; INFN, Trieste) ; Colantoni, M L (INFN, Turin) et al.
2011
- Published in : Nucl. Instrum. Methods Phys. Res., A 631 (2011) 26-39
|
|
10.
|
Design and construction of the fast photon detection system for COMPASS RICH-1
/ Abbon, P (DSM, DAPNIA, Saclay) ; Alexeev, M (INFN, Turin ; Piemonte Orientale U., Alessandria) ; Angerer, H (Munich, Tech. U.) ; Birsa, R (INFN, Trieste) ; Bordalo, P (Lisbon, LIFEP) ; Bradamante, F (INFN, Trieste ; Trieste U.) ; Bressan, A (INFN, Trieste ; Trieste U.) ; Chiosso, M (INFN, Turin ; Turin U.) ; Ciliberti, P (INFN, Trieste ; Trieste U.) ; Colantoni, M (INFN, Turin) et al.
2010 - 17 p.
- Published in : Nucl. Instrum. Methods Phys. Res., A 616 (2010) 21-37
|
|