CERN Accelerating science

CERN Document Server 找到 49 笔记录  1 - 10下一个最後  跳到记录: 检索需时 0.53 秒. 
1.
PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging / Kallitsopoulou, A. (IRFU, Saclay) ; Aleksan, R. (IRFU, Saclay) ; Angelis, Y. (Aristotle U., Thessaloniki) ; Aune, S. (IRFU, Saclay) ; Bortfeldt, J. (Munich U.) ; Brunbauer, F. (CERN) ; Brunoldi, M. (Pavia U. ; INFN, Pavia) ; Chatzianagnostou, E. (Aristotle U., Thessaloniki) ; Datta, J. (SUNY, Stony Brook) ; Desforge, D. (IRFU, Saclay) et al.
The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged particles in ionization gaps by using extreme UV Cherenkov light emitted in a crystal, detected by a Micromegas photodetector with an appropriate photocathode. [...]
arXiv:2411.02532.- 2024-10-16 - 4 p. Fulltext: PDF;
2.
Weak interaction studies via beta-delayed proton emission / Alfaurt, Philippe (LP2i Bordeaux) ; Ascher, Pauline (LP2i Bordeaux) ; Blank, Bertram (LP2i Bordeaux) ; Daudin, Laurent (LP2i Bordeaux) ; Gerbaux, Mathias (LP2i Bordeaux) ; Giovinazzo, Jérôme (LP2i Bordeaux) ; Grévy, Stéphane (LP2i Bordeaux) ; Lecanuet, Samuel (LP2i Bordeaux) ; Lépine, Anais (LP2i Bordeaux) ; Roche, Mathieu (LP2i Bordeaux) et al.
CERN-INTC-2024-050 ; INTC-P-574-ADD-2.
- 2024 - mult..
Original Document (INTC-P-574) - Full text
3.
Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors / Lisowska, M. (CERN ; IRFU, Saclay) ; Aleksan, R. (IRFU, Saclay) ; Angelis, Y. (Aristotle U., Thessaloniki) ; Aune, S. (IRFU, Saclay) ; Bortfeldt, J. (Munich U.) ; Brunbauer, F. (CERN) ; Brunoldi, M. (Pavia U. ; INFN, Pavia) ; Chatzianagnostou, E. (Aristotle U., Thessaloniki) ; Datta, J. (SUNY, Stony Brook) ; Dehmelt, K. (Jefferson Lab) et al.
The PICOSEC Micromegas detector is a~precise-timing gaseous detector based on a~Cherenkov radiator coupled with a~semi-transparent photocathode and a~Micromegas amplifying structure, targeting a~time resolution of tens of picoseconds for minimum ionising particles. Initial single-pad prototypes have demonstrated a~time resolution below 25 ps, prompting ongoing developments to adapt the concept for High Energy Physics applications, where sub-nanosecond precision is essential for event separation, improved track reconstruction and particle identification. [...]
arXiv:2407.09953.- 2024-12-10 - 9 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 1072 (2025) 170151 Fulltext: 2407.09953 - PDF; 1732afb3515e2b936d222cb357afcde6 - PDF; External link: Fermilab Library Server
4.
Decay study of <math><mmultiscripts><mi>Be</mi><mprescripts/><none/><mn>11</mn></mmultiscripts></math> with an optical time-projection chamberDecay study of $^{11}$Be with an Optical TPC detector / ISOLDE Collaboration
The $\beta$ decay of one-neutron halo nucleus $^{11}$Be was investigated using the Warsaw Optical Time Projection Chamber (OTPC) detector to measure $\beta$-delayed charged particles. The results of two experiments are reported [...]
arXiv:2407.09846.- 2024-09-26 - 16 p. - Published in : Phys. Rev. C 110 (2024) 034328 Fulltext: 2407.09846 - PDF; Publication - PDF;
5.
A Novel Diamond-like Carbon based photocathode for PICOSEC Micromegas detectors / Wang, X. (USTC, Hefei ; Hefei, CUST) ; Aleksan, R. (IRFU, Saclay) ; Angelis, Y. (Aristotle U., Thessaloniki) ; Bortfeldt, J. (LMU Munich (main)) ; Brunbauer, F. (CERN) ; Brunoldi, M. (Pavia U. ; INFN, Pavia) ; Chatzianagnostou, E. (Aristotle U., Thessaloniki) ; Datta, J. (Stony Brook U.) ; Degmelt, K. (Jefferson Lab) ; Fanourakis, G. (Democritos Nucl. Res. Ctr.) et al.
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. [...]
arXiv:2406.08712.- 2024-08-12 - 15 p. - Published in : JINST 19 (2024) P08010 Fulltext: 806956891d4956950d85abdbaee8cf0d - PDF; 2406.08712 - PDF; Fulltext from Publisher: PDF; External link: Fermilab Library Server
6.
Single channel PICOSEC Micromegas detector with improved time resolution / Utrobicic, A. (Boskovic Inst., Zagreb) ; Aleksan, R. (IRFU, Saclay) ; Angelis, Y. (Aristotle U., Thessaloniki) ; Bortfeldt, J. (Munich U.) ; Brunbauer, F. (CERN) ; Brunoldi, M. (Pavia U. ; INFN, Pavia) ; Chatzianagnostou, E. (Aristotle U., Thessaloniki) ; Datta, J. (SUNY, Stony Brook) ; Dehmelt, K. (Jefferson Lab) ; Fanourakis, G. (American Coll. of Greece) et al.
This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. [...]
arXiv:2406.05657 ; FERMILAB-PUB-24-0499-CMS-V.
- 29.
Fermilab Library Server - Fulltext - Fulltext
7.
Radiation tolerance of diamond detectors / RD42 Collaboration
Diamond is used as detector material in high energy physics experiments due to its inherent radiation tolerance. The RD42 collaboration has measured the radiation tolerance of chemical vapour deposition (CVD) diamond against proton, pion, and neutron irradiation. [...]
2022 - 5 p. - Published in : J. Phys. : Conf. Ser. 2374 (2022) 012172 Fulltext: PDF;
In : International Conference on Technology and Instrumentation in Particle Physics (TIPP 2021), Online, Canada, 24 - 29 May 2021, pp.012172
8.
Towards robust PICOSEC Micromegas precise timing detectors / Lisowska, M. (CERN ; IRFU, Saclay) ; Angelis, Y. (Aristotle U., Thessaloniki) ; Aune, S. (IRFU, Saclay) ; Bortfeldt, J. (Munich U.) ; Brunbauer, F. (CERN) ; Chatzianagnostou, E. (Aristotle U., Thessaloniki) ; Dehmelt, K. (SUNY, Stony Brook) ; Desforge, D. (IRFU, Saclay) ; Fanourakis, G. (American Coll. of Greece) ; Floethner, K.J. (CERN ; Bonn U., HISKP) et al.
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector consisting of a Cherenkov radiator combined with a photocathode and a MM amplifying structure. A 100-channel non-resistive PICOSEC MM prototype with 10x10 cm^2 active area equipped with a Cesium Iodide (CsI) photocathode demonstrated a time resolution below 18 ps. [...]
arXiv:2303.18141; JLAB-PHY-23-3798.- 2023-07-28 - 8 p.
- Published in : JINST Fulltext: 2303.18141 - PDF; FERMILAB-PUB-23-158-V - PDF; Publication - PDF; External links: JLab Document Server; Fermilab Library Server
In : 7th International Conference on Micro Pattern Gaseous Detectors 2022 (MPGD 2022), Rehovot, Israel, 11 - 16 Dec 2022, pp.C07018
9.
A large area 100-channel PICOSEC Micromegas detector with time resolution at the 20 ps level / Utrobicic, A. (Boskovic Inst., Zagreb) ; Angelis, Y. (Aristotle U., Thessaloniki) ; Aune, Stephan ; Bortfeldt, J. (Munich U.) ; Brunbauer, F. (CERN) ; Chatzianagnostou, E. (Aristotle U., Thessaloniki) ; Dehmelt, K. (SUNY, Stony Brook) ; Desforge, Daniel ; Fanourakis, G. (American Coll. of Greece) ; Floethner, K.J. (CERN ; Bonn U., HISKP) et al.
The PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a semi-transparent photocathode and a Micromegas amplification structure. The first proof of concept single-channel small area prototype was able to achieve time resolution below 25 ps. [...]
arXiv:2304.00056; FERMILAB-PUB-23-159-V; JLAB-PHY-23-3799.- 2023-07-12 - 10 p.
- Published in : JINST Fulltext: FERMILAB-PUB-23-159-V - PDF; e11a25382b5d2a8c79973558bc560c53 - PDF; 2304.00056 - PDF; External links: JLab Document Server; Fermilab Library Server
In : 7th International Conference on Micro Pattern Gaseous Detectors 2022 (MPGD 2022), Rehovot, Israel, 11 - 16 Dec 2022
10.
Experimental setup for Weak Interaction Studies with Radioactive ion-beams WISArD / Atanasov, D (CERN) ; Cresto, F (LPC, Caen) ; Nies, L (CERN) ; Pomorski, M (LP2I, Bordeaux) ; Versteegen, M (LP2I, Bordeaux) ; Alfaurt, P (LP2I, Bordeaux) ; Araujo-Escalona, V (Leuven U.) ; Ascher, P (LP2I, Bordeaux) ; Blank, B (LP2I, Bordeaux) ; Daudin, L (LP2I, Bordeaux) et al.
The article describes the commissioning and technical development of the Weak Interaction Studies with 32Ar Decay (WISArD) experiment, installed at the radioactive ion-beam facility ISOLDE/CERN. The experiment aims to extend the present limits on scalar and tensor currents in the weak interaction and hence search for physics beyond the Standard Model. [...]
2023 - 11 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 1050 (2023) 168159 Fulltext: PDF;

CERN Document Server : 找到 49 笔记录   1 - 10下一个最後  跳到记录:
参见:相似的作者
1 Pomorski, M J
20 Pomorski, M.
2 Pomorski, Marcin
1 Pomorski, Mateusz
2 Pomorski, Michal
您想得到有关这检索条件的最新结果吗?
建立您的 电邮警报 或订阅 RSS feed.
没有寻找到什么? 尝试在以下的服务器查寻:
Pomorski, M 在 Amazon
Pomorski, M 在 CERN EDMS
Pomorski, M 在 CERN Intranet
Pomorski, M 在 CiteSeer
Pomorski, M 在 Google Books
Pomorski, M 在 Google Scholar
Pomorski, M 在 Google Web
Pomorski, M 在 IEC
Pomorski, M 在 IHS
Pomorski, M 在 INSPIRE
Pomorski, M 在 ISO
Pomorski, M 在 KISS Books/Journals
Pomorski, M 在 KISS Preprints
Pomorski, M 在 NEBIS
Pomorski, M 在 SLAC Library Catalog
Pomorski, M 在 Scirus